Ethernet analog input system
4Pages

{{requestButtons}}

Catalog excerpts

Ethernet analog input system - 1

Ethernet analog input system 16 analog inputs, differential, 16-bit Temperaturbereich -40 °C bis 85 °C 16 analog inputs, differential, 16-bit Voltage or current inputs extended memory Buffered real-time clock Stainless steel housing – Fast distributed data acquisition Integrated Ethernet switch 4 GB flash memory, real-time clock On request: Compare logic for synchro trigger signal Synchronisierbar can be synchronised in µs-Bereich in the µs range *Operating temperature Synchronisation/time stamp Synchronisierbar Mehr Info auf in µs-Bereich 24 V digital trigger input www.addi-data.com Time stamp ARM®9 32-bit processor Several MSX-E systems can be synchronised with one an64 MB onboard SDRAM for storing data other in the µs range through a synchro connection. Robust standardized metal housing This allows to start a synchronous data acquisition, to Power Save Mode: Reduced power consumption when Mehr Info auf generate trigger events and to synchronise the time on no acquisition runs www.addi-data.com several MSX-E systems. Furthermore, the systems have a Kaskadierbar Analog inputs Edelstahl time stamp that logs the point in time at which the data • 16 diff. inputs, 16-bit, 5-pin M12 female connector was acquired by the system. • Sampling frequency max. 100 kHz, up to 4 simultaneous System B System A channels Synchronisation • Input ranges: ±5 V, ±10 V (16-bit), 0-5 V, 0-10 V (15-bit) TS TS Synchronisierbar Kaskadierbar in • Gain PGA x1, x2, x10, x20, x100, x200, x1000, x2000 µs-Bereich Edelstahl Edelstahl software-programmable, signals up to +/-5mV (16-bit) are possible • Current inputs 0(4) to 20 mA optional Analog Input System MSX-E3011 Counter Digital I/O System MSX-E1701 Safety features Synchronisierbar in µs-Bereich Mehr Info auf www.addi-data.com Synchronisierbar Status LEDs for fast in µs-Bereich error diagnostics Edelstahl O ptical isolation I nput filters O vervoltage protection ± 40 V I nternal temperature monitoring Interfaces More information on www.addi-data.com Fast 24 V trigger input Ethernet switch with 2 ports Synchronisation/trigger In/Out Line in for 24 V supply and cascading Communication interfaces Kaskadierbar Edelstahl Synchronisierbar in µs-Bereich Edelstahl Drivers and samples Find software for the MSX-E systems at: www.addi-data.com/ downloads • Web server (configuration and monitoring) • Command server SOAP for transferring commands • Data server (TCP/IP or UDP socket) for sending acquisition data • Event server (TCP/IP socket) for sending system events (Diagnostics such as temperature, short-circuits ...) • Command server Modbus TCP and Modbus (UDP) for sending commands info@addi-data.com www.addi-data.com Without synchro: TSAx ≠ TSBx With synchro: TSAx = TSBx The combination of synchronisation and time stamp (TS) allows the clear allocation of signals that were captured by several systems. Acquisition with synchro Acquisition without synchro Value Ax1 Value Ax2 Value Axn

Open the catalog to page 1
Ethernet analog input system - 2

Acquisition modes Auto-refresh mode In auto-refresh mode, the measurement values are updated automatically after each acquisition. The acquisition is initialised once and the values of the channels are stored in the memory/of the MSX-E Ethernet system. The client (e.g. PC, server, PLC, ...) reads the acquired values asynchronously to the acquisition through socket connection, SOAP or Modbus function. Thereby, the new value is read and the old values are overwritten. In addition to the measurement values, the auto-refresh counter can also be read, which allows to sort the measurement values...

Open the catalog to page 2
Ethernet analog input system - 3

Intelligent Ethernet systems, analog – MSX-E3027 Features Merkmale The ConfigTools program allows an easy administration of the MSX-E systems. These are automatically detected in the network. ConfigTools consists of common and specific functions. In addition, with ConfigTools, the complete configuration of a MSX-E system can be saved and transferred to another system of the same type (clone function). Status LEDs 16 analog inputs, differential, 16-bit 5-pin M12 female connector ConfigTools is included in the delivery. Change of IP address Display of web interface Firmware update Save/load...

Open the catalog to page 3
Ethernet analog input system - 4

Specifications* Analog inputs Number/type: 16 differential inputs Architecture: 4 groups of 4 channels each 4-port simultaneous converter with one 4-channel multiplexer per converter Resolution: 16-bit, SAR ADC ± 2.442 mV max. Relative Accuracy (INL): ± 3 LSB max (ADC) Input ranges ± 5 V, ± 10 V (16-bit), 0-5 V, 0-10 V (15-bit) current inputs optional Sampling frequency: 25 kHz per channel / 100 kHz max. software-programmable Common mode rejection: 80 dB min. DC up to 60 Hz (diff. amplifier) Input impedance (PGA): 109 Q // 10nF against GND Bandwidth (-3dB): 160...

Open the catalog to page 4