Overview: The document details the specifications and features of the AD13A.3-14-1 multi-function and multi-tariff three-phase electronic meters designed for use in AMI/AMR systems. These meters are based on advanced ADDAX technology and are intended for residential metering.
Specifications: The meters support DLMS/COSEM standard data models and communication protocols, ensuring interoperability. They feature a built-in real-time clock with an accuracy of 0.5 seconds and are compliant with IEC 62052-21 standards. The meters measure active energy (class C, 0.5), reactive energy (class 2, 4 quadrants), and apparent energy. They also provide power and max demand measurements with configurable integration periods.
Data Storage and Transmission: The meters have non-volatile memory with expandable storage capacity. They support multiple interval profiles and billing profiles. Data transmission can be scheduled or on-demand, with options for remote or local parameterization and software upgrades.
Multi-Rate Metering: The meters support up to 6 tariff registers and 12 changeovers per day, with active and passive tariff plans. A calendar feature allows for up to 12 seasons per year and 30 special days.
Power Load and Energy Quality Control: Built-in relays allow for control of external contactors. The meters monitor quality indexes such as voltage sags, swells, outages, and THD for voltage/current harmonics.
Security and Fraud Protection: The meters include communication encryption and continuous monitoring for fraud, such as meter cover opening and magnetic field detection. They also feature built-in self-control tests.
Technical Specifications: The meters operate within a voltage range of 0.7 Un to 1.2 Un and a temperature range of -40°C to +70°C. They have an IP54 protection level and a mean total lifetime of at least 20 years. The dimensions are 180 x 280 x 68 mm.
Design Features: The terminal block complies with DIN 43857 standards, and the housing is made of non-flammable polycarbonate. The meters can be mounted using three fixing points or on a DIN rail.
See more

Catalog excerpts

Three phase meter with transformer connection-1

ADVANCED SERIES METERS Datasheet BASED ON UP-TO-DATE ADDAX TECHNOLOGY FOR RESIDENTIAL METERING add new tech to your business! © 2022 All Rights Reserved www.addgrup.com

 Open the catalog to page 1
Three phase meter with transformer connection-2

ADVANCED SERIES METERS BASED ON UP-TO-DATE ADDAX TECHNOLOGY FOR RESIDENTIAL METERING AD13A.3-14-1 MULTI-FUNCTION & MULTI-TARIFF THREE-PHASE ELECTRONIC METERS DESIGNED FOR USE IN AMI/AMR SYSTEM OVERALL VIEW Active energy (export/import) Reactive energy (4 quadrants) Apparent energy Measured quantities Calculation of total harmonic distortion factor Multirate registration Built-in clock Load profile Protection level Backup power supply Standard data model, open protocols Optical port DISPLAY INDICATIONS Relay for external contactors Sensor of meter cover opening Sensor of terminal block cover opening...

 Open the catalog to page 2
Three phase meter with transformer connection-3

DLMS/COSEM SUPPORT • Standard data model • Standard communication protocols • Interoperability BUILT-IN CLOCK • Real Time Clock, accuracy 0.5 s. • IEC 62052-21 standard compliant • External synchronization • Sleep mode, battery • Daylight saving time support MEASURED QUANTITIES • Active energy, class C (0,5), export/import • Reactive energy, class 2, 4 quadrants • Apparent energy • Power, Max Demand ✓integration period: 15', 30', 60', day ✓average interval: day, month • Phase voltage/current, instantaneous value, RMS METERING DATA • Actual meter readings • Periodic meter readings: daily, monthly...

 Open the catalog to page 3
Three phase meter with transformer connection-4

TECHINCAL SPECIFICATIONS Accuracy class: - Active energy C (0,5) Reference current, Iref 5 A Maximum current, Imax 10 A Minimum current - Active energy 0.01 Iref - Reactive energy 0.02 Iref Starting current: - Active energy 0.001 Iref - Reactive energy 0.003 Iref Voltage range Reference frequency Meter constant: - Active energy - Reactive energy Temperature range Internal clock Clock accuracy (at 25°C) (IEC 62052-21) PLC raw data rate (with convolutional coding): - PRIME v1.3.6, CENELEC A band 3-95 kHz - PRIME v1.4 for each of 1, 3-8 channel in the band 3 kHz up to 500 kHz - G3-PLC CENELEC A...