ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz Adash 3900-II On-line vibration monitoring system Application: ! Predictive maintenance ! Measurement of bearing condition ! Machine protection systems ! Machine control systems ! Machine monitoring systems Characteristics: ! Measurement of vibration (mm/s, in/s) in freq.band 10-1000Hz ! Measurement of bearing condition (HF parameter, g=9.82m/s2) in freq.band 5-16kHz ! Wideband measurement of acceleration (g=9.81m/s2) in freq.band 0.8Hz-16kHz ! Measurement of TRUE RMS and TRUE PEAK values ! A3900-II settings from computer via RS232 interface ! A3900-II is possible to connect to memory module for data storage (standard CompactFlash card) ! Adjustable current loop 4-20mA for actual value output ! Complete checking of failures. Current of the loop drops to 3.5 mA immediately and the control system does not generate any incorrect response ! Indication of exceeding the predefined vibration limits (ALARM, ALERT) ! ALARM limit relay ! The quality acceleration ICP sensor is used ! Continuous check of break of cable or sensor ! Simple connection to control systems (PLC) ! Simple installation to DIN rail Ref: 07032006RS " User’s guide

Open the catalog to page 1
A3900 - Online condition monitoring system - 3

ADASH Ltd. Adash 3900-II ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz 3 Before the First Start-up 1. Never connect any sensor to the ICP input of the unit other than the ICP sensor type! If you are not sure, consult the procedure with your supplier. 2. Never connect the unit directly to the mains voltage ! 3. Use only power supply units with a nominal voltage 20 - 28V DC to supply the unit ! 4. Use only power supply units with a nominal voltage 10 - 30V DC to...

Open the catalog to page 3
A3900 - Online condition monitoring system - 4

ADASH Ltd. Adash 3900-II ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz 4 Unit description The unit Adash 3900-II is simple tool for vibration measurements, which is intended for process control and reliability systems, machinery protection systems and generally for all the applications concerning the maintenance and monitoring of machinery state. Thus, a large variety of applications are possible for motors, fans, pumps, gearboxes, small turbines, bearing...

Open the catalog to page 4
A3900 - Online condition monitoring system - 5

ADASH Ltd. Adash 3900-II ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz 5 Three-digits, seven-segments display - the report list After start or restart 8.8.8. plus all LEDs are ON (user can check, whether all front panel components light) X.XX firmware version (e.g. 2.20), all LEDs are OFF During the Measurement XXX measured value (0.00 - 999), there are three LEDs, which indicated a measured unit. The "LOOP" LED indicates status of current loop and relation to...

Open the catalog to page 5
A3900 - Online condition monitoring system - 6

ADASH Ltd. Adash 3900-II ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz 6 Output signal from sensor The BNC connector is the output of measured signal. It is possible to connect an external vibrationanalyser or other evaluation device for independent measurement of the signal. The 3900 II unit is able to accept max. signal from sensor in range +/- 5V. You should use the sensor with suitable sensitivity. Signal on the BNC connector is separated from the sensor by...

Open the catalog to page 6
A3900 - Online condition monitoring system - 7

ADASH Ltd. Adash 3900-II ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz 7 A3900-II connection Terminals description Power supply terminals +24V positive pole of supply voltage 20–28 V 0V negative pole of supply voltage They are two pairs and they are intended for power supply of module and current loop (in active mode). Input terminals +ICP positive pole of ICP -ICP negative pole of ICP SHLD sensor cable shield Output terminals of current loop + LOOP positive pole of...

Open the catalog to page 7
A3900 - Online condition monitoring system - 8

ADASH Ltd. Adash 3900-II ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz 8 Sensor connection A3900-II unit is intended to measure the vibrations by acceleration sensor. A real sensibility of used sensor (mV/g) can be set by PC. A3900-II is possible join to PC by standard crossing cable RS232 see Detailed description of menu. For sensor connection is recommended usage of shielded twisted pair, which is resistant to electromagnetic field. The Adash Ltd. supplies the...

Open the catalog to page 8
A3900 - Online condition monitoring system - 9

ADASH Ltd. Adash 3900-II ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz 9 During unit setup by PC and when measuring is stopped, then the output current is 3.5mA. If input of unit is overload by high-level signal, then output current is 3.5mA. If any error is detected (e.g. ICP error), then output current is 3.5mA. If current loop is switched-off by user (Loop max. value =0), then output current is 3.5mA. If blackout occurs or if unit is restarted, then output...

Open the catalog to page 9
A3900 - Online condition monitoring system - 10

ADASH Ltd. Adash 3900-II ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For next technical and contact information visit www.adash.net, www.adash.cz 10 A3900-II setting A3900-II module is set by PC in the Hyper Terminal. Hyper Terminal is standard part of Windows. After connection to PC (by RS-232), Hyper Terminal must be started and setting. Connection RS232 to A3900-II unit - see Serial interface RS232. Hyper Terminal setting: 1/ Run Hyper Terminal (Windows Start / Programs / Accessories / Communication / Hyper Terminal). 2/ Create a new...

Open the catalog to page 10