A1211 MINI
48Pages

{{requestButtons}}

Catalog excerpts

A1211 MINI - 1

Ultrasonic Flaw Detector A1211 Mini ACOUSTIC CONTROL SYSTEMS ULTRASONIC FLAW DETECTOR A1211 MINI OPERATION MANUAL Acoustic Control Systems – ACS Group Saarbrücken, Germany 2019 1 Operation Manual

Open the catalog to page 1
A1211 MINI - 2

ACOUSTIC CONTROL SYSTEMS Operation Manual Ultrasonic Flaw Detector A1211 Mini

Open the catalog to page 2
A1211 MINI - 3

Ultrasonic Flaw Detector A1211 Mini ACOUSTIC CONTROL SYSTEMS Operation Manual

Open the catalog to page 3
A1211 MINI - 4

ACOUSTIC CONTROL SYSTEMS Ultrasonic Flaw Detector A1211 Mini Operation Manual

Open the catalog to page 4
A1211 MINI - 5

Ultrasonic Flaw Detector A1211 Mini ACOUSTIC CONTROL SYSTEMS The current operation manual (hereinafter referred to as “ operation manual”) contains technical specifications, description of the design and operational principle, as well as information, required for proper operation of the ultrasonic flaw detector А1211 Mini (hereinafter referred to as flaw detector or instrument). Prior to start using the instrument it is necessary to read the present manual and understand it. The manufacturer continually improves the instrument, increasing its reliability and operation convenience. This can...

Open the catalog to page 5
A1211 MINI - 6

ACOUSTIC CONTROL SYSTEMS Ultrasonic Flaw Detector A1211 Mini 1.1 INTENDED USE 1.1.1 Intended use and area of application The instrument is a handheld portable ultrasonic (US) instrument of general purpose. The flaw detector is designed for search, definition of coordinates and estimation of various infringements sizes in the continuity and uniformity of a material in products made from metals and plastic. The flaw detector allows to form, register and keep in non-volatile memory time realizations of echo signals, and also transfer saved data to a PC for further analyses and documentation....

Open the catalog to page 6
A1211 MINI - 7

ACOUSTIC CONTROL SYSTEMS Ultrasonic Flaw Detector A1211 Mini The main technical specifications of the instrument are listed in the Table 1. Table 1 Ultrasound reconstruction range Operating frequencies of transducers Reconstruction range of the calibrated amplifier Measurement range of the depth of the flaw location (steel) with straight beam transducers: with S3568 2.5A0D10CL with D1771 4.0A0D12CL Limits of permissible absolute measurement accuracy of the depth of the flaw location (steel) with the straight beam transducers, where H – measured depth of the flaw location in mm Measurement...

Open the catalog to page 7
A1211 MINI - 8

ACOUSTIC CONTROL SYSTEMS Ultrasonic Flaw Detector A1211 Mini Limits of the permissible absolute set accuracy of the gain Rated supply voltage Minimal battery operation time, hours Overall dimensions of the electronic unit, max. Maximum weight of the electronic unit Mean time between failures Average service life Sockets for connecting transducer Colour TFT display Membrane keyboard Figure 1 Operation Manual Plug of the USB Micro B connector Fastener for the belt

Open the catalog to page 8
A1211 MINI - 9

Ultrasonic Flaw Detector A1211 Mini ACOUSTIC CONTROL SYSTEMS 1.3 INSTRUMENT DESIGN AND OPERATION 1.3.1 Instrument design The instrument includes an electronic unit (Figure 1), to which changeable piezoelectric transducers are connected via cables. In the upper part of the front panel a TFT display is situated, it displays the measurement results and service information, necessary for using the instrument. The display provides full visual control of the measurement process with colored indication. Under the display a film keyboard is located used to control the instrument. On the upper side...

Open the catalog to page 9
A1211 MINI - 10

ACOUSTIC CONTROL SYSTEMS Ultrasonic Flaw Detector A1211 Mini While working with the echo-method with a single crystal or a dual search transducer the temporary position of the echo-signal on the screen is in proportion to the distance from the reflector to the transducer. 1.3.3 Operating modes The main operating mode is the FLAW DETECTOR mode, additional STOP and SETTINGS modes are present. In the operating mode the emission pulse is formed, the measurements are made, the received echo-signal is amplified and displayed on the screen. The STOP mode is used for freezing the signal realization...

Open the catalog to page 10
A1211 MINI - 11

ACOUSTIC CONTROL SYSTEMS Ultrasonic Flaw Detector A1211 Mini The display with the vertical orientation in FLAW DETECTOR mode is shown on the Figure 6. On the Figure 7 the display is shown with horizontal left orientation in FLAW DETECTOR mode Battery level Measurements result panel Current configuration name Measurements result panel Additional information field Battery level Additional information field 1 Measuring cursor Amplitude marker Measuring cursor Amplitude marker Signal representation field Scale sweep Strobe Scale sweep Pictogram menu Pictogram menu Current configuration name...

Open the catalog to page 11
A1211 MINI - 12

ACOUSTIC CONTROL SYSTEMS Ultrasonic Flaw Detector A1211 Mini The keyboard of the instrument (Figure 8) has 11 functional keys and an on/off key. Main functions of the keys: The key (ON / OFF) is used for turning the instrument on/off. NOTE: THE INSTRUMENT AUTOMATICALLY TURNS OFF AFTER 10 MINUTES WHEN NO KEY IS PRESSED AND NO MEASURING IS PERFORMED! NOTE: AFTER 2 MINUTES THE ILLUMINATION OF THE SCREEN IS AUTOMATICALLY SET TO THE MINIMAL VALUE 20% IF NO KEY IS PRESSED AND NO MEASURING IS PERFORMED! The functional keys (F) are used for different operations depending on the selected mode of the...

Open the catalog to page 12
A1211 MINI - 13

Ultrasonic Flaw Detector A1211 Mini ACOUSTIC CONTROL SYSTEMS 2.1 OPERATIONAL LIMITATIONS The instrument is designed for operation under environmental conditions specified in the section 1.1.2. 2.2 PREPARING THE INSTRUMENT FOR USE 2.2.1 Preparation of the surface The surface of the tested object should be cleaned from dirt and sand, if it is covered with corrosion, then remove the loose rust and apply more contact liquid on the smooth surface. Cleaning rough corroded surfaces improves the measurement certainty and provides a longer service life of the transducer. 2.2.2 Connecting the...

Open the catalog to page 13
A1211 MINI - 14

ACOUSTIC CONTROL SYSTEMS Ultrasonic Flaw Detector A1211 Mini 2.2.3 Switching the instrument ON/OFF To turn the instrument on the key should be pressed. At the moment of turning on a short tuneful signal will ring. On the display of the instrument the main screen is shown for 2 seconds with the name of instrument and version of the firmware (Figure 11). The instrument will automatically enter the mode, which was set at the moment of the last switching off, with corresponding settings. Turning the instrument off is done by pushing the key or automatically after 10 minutes when no key is...

Open the catalog to page 14