Main Technical Specifications
  • Transducer Type: Contact angle beam single
  • Nominal Frequency: 5 MHz
  • Nominal Beam Angle: 60°
  • Nominal Echo Pulse Duration: 1.1 µs
  • Nominal Relative Bandwidth: 50%
  • Nominal Sensitivity: -80 dB
  • Piezoelement Diameter: 6 mm
  • Nominal Piezoelement Capacity: 1100 ± 100 pF
  • Connector Type: LEMO 00.250
  • Operation Temperature Range: -20 to +50°C
  • Dimensions: 36×18×16 mm
  • Weight: 20 g
Measurement Conditions and Used Equipment
  • Excitation: Rectangular pulse with amplitude 20 V and duration 200 ns
  • Receiver: Amplifier with 0.01-15 MHz bandwidth and 400 Ω input impedance
  • Damping Resistor: 100 Ω (connected in parallel to the transducer)
  • Cable: Single LEMO-LEMO with wave resistance 50 Ω and 1.2 m length
  • Samples: Calibration blocks СО-3, СО-2, and standard sample СО-1M of steel 20
Measurement Results
  • Echo Pulse for 50 mm Thickness: Includes amplitude and spectral amplitude data
  • Reverberation-Noise Characteristics (RNC): Without acoustic load and DGS diagram for flat-bottomed reflectors
Calculated Parameters and Acceptance Results
  • Work Frequency: 5.3 MHz (within 4 – 6 MHz tolerance)
  • Beam Angle in Steel: 60° (within 58.5 – 61.5° tolerance)
  • Echo Pulse Duration: 0.48 µs (<= 1.1 µs)
  • Relative Spectrum Bandwidth: 60% (within 30 – 70%)
  • Sensitivity: -64 dB (>= -80 dB)
  • Sensitivity Margin: 63 dB (>= 40 dB)
  • Echo Pulse Amplitude: 12 mV
  • Transducer Offset: 9 mm
  • Delay: 4.6 µs
  • Spectrum Maximum Frequency: 5.3 MHz
  • Lower Spectrum Frequency: 3.8 MHz
  • Upper Spectrum Frequency: 7 MHz
  • Spectrum Bandwidth: 3.2 MHz
See more

Catalog excerpts

S5096 – angle-beam transducer 5 MHz / 60°-1

Ultrasonic piezoelectric transducer S5096 5.0A60D6CS DATA SHEET Main technical specifications Transducer type: Nominal frequency: Nominal beam angle: Nominal echo pulse duration: Nominal relative band width: Nominal sensitivity: Piezoelement diameter: Nominal piezoelement capacity: Connector type: Operation temperature range: Dimensions: Weight: Contact angle beam single 5 MHz 60 ◦ 1.1 µs 50 % -80 dB 6 mm 1100 ± 100 pF LEMO 00.250 from -20 to +50 ◦ C 36×18×16 mm 20 g Measurement conditions and used equipment Excitation: Rectangular pulse with amplitude 20 V and duration 200 ns, equal to half-period of nominal frequency oscillations. Amplifier with 0.01-15 MHz bandwidth and 400 Ω input impedance. Effective noise level, normalized to the amplifier input level, is less than 20 µV. Damping resistor: 100 Ω (connected in parallel to the transducer). Single LEMO-LEMO with wave resistance 50 Ω and 1.2 m length. 1. Calibration block СО-3 from the set of ultrasonic calibration blocks 55724, serial number 190212; 2. Calibration block СО-2 from the set of ultrasonic calibration blocks 55724, serial number 190212; 3. Standard sample СО-1M of steel 20, ultrasonic shear wave velocity 3226 m/s. Measurement results Spectral amplitude, rel. units Echo pulse for 50 mm thickness and its spectrum

 Open the catalog to page 1
S5096 – angle-beam transducer 5 MHz / 60°-2

Reverberation-noise characteristics (RNC) of the tranducer without acoustic load and DGS diagram for flat bottomed reflectors with area 1, 3 and 10 mm2 The level of 0 dB corresponds to the amplitude of the transducer excitation pulse. Calculated parameters and acceptance results Parameter Work frequency (Mean of border spectrum frequencies) , MHz Beam angle in steel , Echo pulse duration (at -20 dB level from maximum) , µs Relative spectrum bandwidth (at -6 dB level) , % Sensitivity (bottom echo pulse and excitation pulse amplitudes’ ratio), dB Sensitivity margin above the RNC in the time interval...

 Open the catalog to page 2

All ACS-Solutions GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.