Intended Use: The Ultrasonic Transducer S1905 is designed for use in ultrasonic measurement systems, where it functions as a transmitter in conjunction with a reference transducer acting as a receiver.
Main Technical Specifications:
  • Type of generated wave mode: Longitudinal
  • Nominal frequency: 25 kHz
  • Operating frequency: 25 ± 10 kHz
  • Double conversion ratio: 70 dB or better
  • Relative frequency bandwidth: Greater than -90%
  • Electric capacity of the piezoelectric element: 3600 ± 150 pF
  • Maximum excitation pulse voltage: Less than 200 V
  • Connector type: LEMO ERN.00.250
  • Overall dimensions: Less than 80ר18 mm
  • Weight: Less than 100 g
  • Operating temperature range: -20 °C to +50 °C
Measurement Conditions and Equipment Used: The transducer characteristics are measured with a reference transducer, both connected with a nip force of 4 N. The tested transducer acts as a transmitter, and the reference as a receiver. The excitation signal is a square pulse with an amplitude of 200 V and a duration of 10 μs. The receiver uses an integrating amplifier with a bandwidth of 0.01 Hz to 400 kHz, input resistance of 4 kΩ, and equivalent input noise voltage of 10 μV. Measurements are conducted at a temperature of 24 °C and relative humidity of 17%.
Measured Characteristics:
  • Echo pulse duration: 117.4 μs
  • Operating frequency: 25.3 kHz
  • AFC frequency maximum: 28.0 kHz
  • Double conversion ratio AFC maximum: -83.9 dB
  • Lower AFC frequency: 17.4 kHz
  • Upper AFC frequency: 33.2 kHz
  • Transducer delay: 0.0 μs
  • Relative frequency bandwidth (at -6 dB): 62.6%
Warranty: The product comes with a warranty period of 3 months from the date of sale.
See more

Catalog excerpts

S1905 – longitudinal wave DPC transducer 25 KHz-1

Ultrasonic transducer S1905 DATA SHEET Intended use Main technical specifications Type of generated wave mode: Nominal frequency: Operating frequency: Double conversion ratio: Relative frequency bandwidth: Electric capacity of the piezoelectric element: Maximum excitation pulse voltage: Connector type: Overall dimensions: Weight: Operating temperature range: Longitudinal 25 kHz (25 ± 10) kHz 70 dB or better > -90 % (3600 ± 150) pF < 200 V LEMO ERN.00.250 < 80ר18 mm < 100 g -20 °C to +50 °C Measurement conditions and equipment used The measurement of the tested DPC transducer characteristics occurs in combination with the reference DPC transducer, whereby both transducers are connected by their tips with the nip force of 4 N. The tested transducer operates as a trans- mitter and the reference transducer operates as a receiver of ultrasonic waves. The double conversion ratio Srel is determined as a ratio value between the received signal amplitude on the reference transducer and excitation pulse amplitude on the tested transducer. Excitation signal: square pulse with the amplitude 200 V, duration 10 μs, equal to half period of the nominal. Receiver parameters: integrating amplifier with the bandwidth 0.01 Hz – 400 kHz, input resistance 4 kΩ, equivalent input noise voltage 10 μV. Environmental temperature 24 °C, rel. 17 %. conditions: Amplitude-frequency response Level, rel.un. Measured characteristics Shape of the measured pulse Echo pulse duration τ: AFC frequency maximum ƒp: Double conversion ratio AFCmaximum Srel: Relative frequency bandwidth (at -6 dB) Bw: ©Acoustic Control Systems - ACS Group Warranty period 3 months fro

 Open the catalog to page 1

All ACS-Solutions GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.