1. Catalogs
  2. ACS-Solutions GmbH
  3. S1844 – longitudinal wave DPC transducer 50 KHz (non-damped, narrow-band)

S1844 – longitudinal wave DPC transducer 50 KHz (non-damped, narrow-band)

S1844 – longitudinal wave DPC transducer 50 KHz (non-damped, narrow-band)

Product catalog summary
Intended Use: The S1844 is a general-purpose low-frequency dry-point-contact (DPC) transducer designed for transmitting or receiving shear-horizontal ultrasonic waves in materials with high scattering properties such as concrete, wood, and stones. It is available in a ready-made housing with a Lemo00 plug or can be customized for specific applications, including transducer arrays.
Main Technical Specifications:
  • Transducer Type: Dry point contact for couplant-free operation
  • Wave Mode: Shear horizontal
  • Nominal Frequency: 50 kHz
  • Electric Capacity: 5000±500 pF
  • Maximum Excitation Pulse Voltage: 400 V
  • Delay Time: 0.9 µs
  • Connector Type: LEMO 00.250
  • Dimensions: 46x15 mm
  • Weight: 10 g
  • Operating Temperature Range: -20 to +50 °C
Measurement Conditions and Equipment: The performance is evaluated by comparing the received signal amplitude on a reference transducer to the excitation pulse amplitude on the tested transducer. The excitation signal is a square pulse with a 200 V amplitude and 10 µs duration. The receiver uses an integrating amplifier with a bandwidth of 1 kHz to 15 MHz, input resistance of 4 kΩ, and equivalent input noise voltage of 10 µV. Measurements are conducted at 25°C with 42% relative humidity.
Measured Characteristics:
  • Echo Pulse Duration: 23.9 µs
  • Amplitude-Frequency Response Maximum Frequency (fp): 54.4 kHz
  • Lower Frequency (fl): 22.1 kHz
  • Upper Frequency (fu): 84.7 kHz
  • Operating Frequency (fc): 53.4 kHz
  • AFC Maximum Srel: -50.9 dB
  • Absolute Transmission Bandwidth: 62.6 kHz
  • Relative Transmission Bandwidth: 117%
Measurement Procedure: The characteristics of the tested DPC transducer are measured in conjunction with a reference DPC transducer. Both transducers are connected by their tips with a nip force of 2 N. The tested transducer functions as a transmitter, while the reference transducer acts as a receiver of ultrasonic waves.
See more

Catalog excerpts

S1844 – longitudinal wave DPC transducer 50 KHz (non-damped, narrow-band)-1

Ultrasonic transducer S1844 DATA SHEET Intended use A general-purpose low-frequency dry-point-contact (DPC) transducer S1844 for transmitting or receiving shear-horizontal ultrasonic waves in highly scattering materials (concrete, wood, stones etc.) can be used in ready-made housing with the Lemo00 plug or non-wired for self-tailored applications, e.g. for customization of transducer arrays by the customer. Main technical specifications Type of transducer: Type of generated wave mode: Nominal frequency: Electric capacity of the piezoelectric element: Maximum excitation pulse voltage: Delay time in transducer protector: Connector type: Overall dimensions: Weight: Operating temperature range: Dry point contact for couplant free operation Shear horizontal 50 kHz 5000±500 pF 400 V 0.9 µs LEMO 00.250 46x 15 mm 10 g -20 to +50 ◦ C Measurement conditions and equipment used The measurement of the tested DPC transducer characteristics occurs in combination with the reference DPC transducer, whereby both transducers are connected by their tips with the nip force of 2 N. The tested transducer operates as a transmitter and the reference transducer operates as a receiver of ultrasonic waves. The double conversion ratio AFCmaximum Srel is determined as a ratio value between the received signal amplitude on the reference transducer and excitation pulse amplitude on the tested transducer. Excitation signal: square pulse with the amplitude 200 V, duration 10 µs, equal to half period of the nominal frequency. Reciever parameters: integrating amplifier with the bandwidth 1kHz – 15 MHz, input resistance 4 kΩ, equivalent input noise voltage 10 µV. Environmental conditions: Measured characteristics Amplitude-frequency response Shape of the measured pulse Echo pulse duration: Absolute transmission bandwidth P : Relative transmission bandwidth Bw :

 Open the catalog to page 1

All ACS-Solutions GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.