1. Catalogs
  2. ACS-Solutions GmbH
  3. S1823 – Dual-mode DPC transducer 120 KHz

S1823 – Dual-mode DPC transducer 120 KHz

S1823 – Dual-mode DPC transducer 120 KHz

S1823 – Dual-mode DPC transducer 120 KHz

Product catalog summary
Intended Use
The S1823 ultrasonic transducers are designed for dry point contact inspections of non-metallic materials to assess their physical and mechanical properties. They function as a transmitter-receiver pair.
Main Technical Specifications
  • Transducer Type: Dry-point-contact
  • Wave Mode: Longitudinal or shear-horizontal
  • Special Feature: Couplant-free operation
  • Nominal Frequency: 120 kHz
  • Electric Capacity: 1.400 ± 200 pF
  • Max Excitation Pulse Voltage: 400 V
  • Connector Type: OSMT or LEMO00
  • Dimensions: 11x22.6 mm
  • Weight: 14 g
Measurement Conditions and Equipment
Measurements are conducted at 25ºC and 43% relative humidity using a fluoroplastic tapered sample. The transducer operates in transmission mode with a 5 MHz piezoelectric receiver. A half-sine video pulse generator with 200 V amplitude is used, and the receiving path includes an AKS310 amplifier with specific parameters.
Excitation Scheme
For longitudinal waves, piezoelectric elements are connected in parallel and co-phasal. For shear waves, they are connected antiphasal via a transformer with a 1:1 ratio.
Measured Characteristics
  • Longitudinal Wave Mode:
    • Max Half-Wave Amplitude: 1.9 mV
    • Lower Band Frequency: 110 kHz
    • Pulse Duration: 170 msec
    • Upper Band Frequency: 144 kHz
    • Max Spectrum Frequency: 127 kHz
    • Average Band Frequency: 127 kHz
    • Relative Frequency Band: 26.9%
  • Shear Wave Mode:
    • Max Half-Wave Amplitude: 2.3 mV
    • Lower Band Frequency: 95.2 kHz
    • Pulse Duration: 200 msec
    • Upper Band Frequency: 134 kHz
    • Max Spectrum Frequency: 117 kHz
    • Average Band Frequency: 115 kHz
    • Relative Frequency Band: 34%
See more

Catalog excerpts

S1823 – Dual-mode DPC transducer 120 KHz-1

Ultrasonic transducer S1823 DATASHEET Intended use Dry point contact ultrasonic transducers S1823 with wave type switching and a are used to perform ultrasonic inspections of various non-metallic materials and products to determine their physical and mechanical properties. The transducers are regularly used as a transmitter-receiver couple. Main technical specifications Type of transducer: Type of generated wave mode: Dry-point-contact Longitudinal or shear-horizontal Special properties: Couplant-free operation Nominal frequency: 120 kHz Electric capacity of the piezoelectric element: 1.400 ± 200 pF Maximum excitation pulse voltage, V: 400 V Connector type: OSMT or LEMO00 Overall dimensions: 11x22.6 mm Weight: 14 gr Measurement conditions and equipment used Temperature 25ºC, rel. humidity 43% The method of passing of the ultrasonic waves through a tapered sample from fluoroplastic is used. The tested transducer operates in the transmission mode. As an ultrasonic pulse receiver, a broad-band single-crystal piezoelectric transducer with the operating frequency 5 MHz and effective aperture 10 mm is used. Generator transmitting signal: half-sine video pulse with 200 V amplitude and 2.0 mcs duration time at the -20 dB level from the maximum. Receiving path parameters: the integrating amplifier AKS310 is used. The amplification is 400 at 100 kHz frequency, the band 2 is 250 kHz and the input impedance is 40 kOhm. In the longitudinal wave generation and receiving mode, the piezoelectric elements of the tested transducer are connected in parallel and co-phasal. In the shear wave mode, they are connected antiphasal via the transformer with the interrupted ferrite core, the transformation ratio is 1:1 and the inductivity of each coil is 20 mH. Excitation scheme for longitudinal and shear wave generation © Acoustic Control Systems – ACS Gro

 Open the catalog to page 1
S1823 – Dual-mode DPC transducer 120 KHz-2

Measured characteristics in the longitudinal wave mode Amplitude frequency response Shape of the measured pulse Signal parameters Maximum half-wave amplitude of the pulse, mV Pulse duration at the -14 dB, msec Maximum spectrum frequency, kHz Relative frequency band at the -3 dB level, % Lower band frequency at the 3 dB level, kHz Upper band frequency at the 3 dB level, kHz Average band frequency at the -3 dB level, kHz Average compound band frequency at the -3 dB level, kHz Measured characteristics in the shear wave mode Amplitude frequency response Shape of the measured pulse Signal parameters...

 Open the catalog to page 2

All ACS-Solutions GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.