1. Catalogs
  2. ACS Control-System GmbH
  3. Flowcont UN data sheet

Flowcont UN data sheet

Flowcont UN data sheet

Flowcont UN data sheet

Product catalog summary
Product Overview
The Flowcont UN is an ultrasonic flowmeter designed for non-contact measurement of both conductive and non-conductive liquids. It utilizes the phase difference process to accurately measure flow volumes without direct contact with the liquid.
Key Features
  • Non-contact ultrasonic sensor suitable for various liquids.
  • Compact design with no moving parts, ideal for confined spaces.
  • High chemical resistance due to a seal-free sensor design.
  • Operates within a process temperature range up to 80°C and pressure up to 10 bar.
  • Large text display for easy setup and operation.
  • EHEDG certification and FDA compliance for hygienic applications.
  • Maintenance-free, reducing operational costs.
  • Adjustable measuring ranges to minimize variant requirements.
Technical Specifications
  • Measuring principle: Ultrasonic sensor.
  • Nominal widths: NW 10, NW 15, NW 20, NW 25.
  • Process temperature: 0°C to +80°C.
  • Process pressure: Max 10 bar for NW 10 and NW 15; Max 6 bar for NW 20 and NW 25.
  • Accuracy: 2% of final value; Reproducibility: 0.5%.
  • Resolution varies by nominal width, e.g., NW 10: 0.003 l/min.
Mechanical and Electrical Details
  • Process connections available in various sizes and types (G and NPT threads).
  • Wetted parts and housing made from PSU material.
  • Supply voltage: 18 V DC to 30 V DC.
  • Protection class: III; Enclosure rating: IP 67.
  • Electrical connections: M12x1, 5-pin or 8-pin.
Recommended Accessories
  • Various M12 cables available in different lengths and materials (PVC, PUR).
Dimensional Drawings
Detailed dimensional drawings are provided for each nominal width, showing process connections and overall dimensions in millimeters and inches. Key dimensions for NW 10, 15, 20, and 25 are highlighted, emphasizing the importance of maintaining consistent tube diameters before and after the device for accurate measurements.
Mounting Instructions
Proper installation is crucial for accurate volume measurement. Minimum inlet and outlet paths are specified based on the device's nominal width. For high-temperature applications (≥ 60°C), the device should be mounted upside down. Correct and incorrect positioning is illustrated, and operational settings can be adjusted using arrow keys, with options to save settings or exit menus.
Operational Settings
The flow sensors display current flow values in liters per minute, total volume, and a bar graph indicating the percentage of the current measurement range. Users can set parameters for analog output, pulse output, status output, measurement units, creeping flow, and medium calibration. The tube must be fully filled, and the flow direction is specified.
Construction and Specifications
The Flowcont UN is an ultrasonic flow meter designed for non-conductive liquids. It supports various tube sizes with specified minimum and maximum flow rates. Sensor material options include PSU black, and process connectors are available in G1 pipe thread, N1 thread NPT, and C1 Clamp (DIN11864-3). Electronics options include current outputs with different configurations for flow rate monitoring and empty pipe detection.
See more

Catalog excerpts

Flowcont UN data sheet-1

Flow meter Type: Flowcont UN Ultrasonic flowmeter Flowcont UN Non-contact flow measurement Product description The non-contact, ultrasonic flow sensor Flowcont UN detects the flow volumes of conductive and nonconductive liquids. Swimming against the current requires more strength than with the current – this is the simple fact on which ultrasonic flow measurement according to the phase difference process is based. The device has a compact design, and its wide range of possible applications means it can also be used in restricted spaces. The seal-free sensor design, with high-quality polysulfone (Ultrason S) combined with enclosure rating IP 67, not only makes it possible to use the device in harsh ambient conditions, but also guarantees high process reliability. The large text display also helps ensure simple, fast and problem-free commissioning. At a glance • Flow sensor for conductive and nonconductive liquids • No moving parts, compact design • Process temperature up to 80 °C, process pressure up to 10 bar • High chemical resistance thanks to seal-free sensor design • Large display with membrane keyboard • Integrated teaching tube detection • Easy-to-clean, hygienic variants available (EHEDG certification and conformance with FDA), CIP capable Your benefits • Maintenance-free flow sensor; saves maintenance costs • Adjustable measuring ranges, reduced number of variants • Can be used for conductive and nonconductive liquids – fewer variants and lower storage costs • Straight measuring tube reduces pressure loss, thus saving energy costs • Sensor without seals increases process reliability and availability • Flexible measurement system for all industries Specifics liquids display easy-to-use compact design up to closed operating interface 10 bar pressure Order code . . . . . . . . page |08| ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | [email protected] |1|

 Open the catalog to page 1
Flowcont UN data sheet-2

Detailed technical data Features Measuring principle Ultrasonic sensor Medium Fluids Nominal width measuring tube NW 10 / NW 15 / NW 20 / NW 25 Process temperature 0 °C ... +80 °C Process pressure NW 10 und NW 15: Max. 10 bar / NW 20 und NW 25: Max. 6 bar EHEDG approval yes Performance Minimum flow NW10: 0.3 l/min NW15: 0.9 l/min NW20: 3.5 l/min NW25: 5 l/min Maximum flow NW10: 21 l/min NW15: 36 l/min 6 NW20: 0 l/min NW25: 240 l/min Inlet zone NW10: 10 cm NW15: 30 cm NW20: 50 cm NW25: 80 cm Outlet zone NW10: 0 cm NW15: 5 cm NW20: 10 cm NW25: 20 cm Conductivity No limitation Accuracy 2 % (of final...

 Open the catalog to page 2
Flowcont UN data sheet-6

Operation FFU Flow sensors operation Select parameter or chance values by using the arrow keys Set: Save settings Esc: Leaving current selection level / menu item Display information: • Current flow value in l/min • Volume in l • Bar graph with percentage value of current measurement range Setting of: • Analog output • Pulse output • Status output • Measurement unit • Creeping flow • Medium calibration mounting instructions In applications where the flowmeter is exposed to high temperatures (t ≥ 60°C), the device should be mounted upside down: Correct positioning Flow direction False positioning...

 Open the catalog to page 6
Flowcont UN data sheet-7

Set: Save settings Esc: Leaving current selection level / menu item Display information: Mounting instructions flow value in l/min • Current • Volume in l • Bar graph with percentage value of current Type: Flowcont UN measurement range Setting of: • Analog output • Pulse output • Status output • Measurement unit • Creeping flow • Medium calibration mounting instructions In applications where the flowmeter is exposed to high temperatures (t ≥ 60°C), the device should be mounted upside down: Correct positioning Flow direction False positioning Tube has to be fully filled Inlet and outlet paths...

 Open the catalog to page 7
Flowcont UN data sheet-8

Order code construction UN Standard ultrasonic flow meter for non-conductive liquids Tube size 10 NW 10 Minimum flow 0,3 l/min...Maximum flow 21 l/min 15 NW 15 Minimum flow 0,9 l/min...Maximum flow 36 l/min 20 NW 20 Minimum flow 3,5 l/min...Maximum flow 60 l/min 25 NW 25 Minimum flow 5 l/min...Maximum flow 240 l/min Sensor material 1 PSU black Process connector G1 Pipe thread G acc. to ISO 228 (Standard) N1 Thread NPT C1 Clamp (DIN11864-3) BKS form A Elektronik I0 Current output, 1 transmitter output, M12x1, 5-pin (Standard) Elektronics: 1 analog output: 4 mA … 20 mA, 0 mA … 20 mA current flow,...

 Open the catalog to page 8

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.