Electric with HT Thermal Storage for Heating Water and DHW Heater In one package Applications Apartment Buildings Condominium Buildings Educational Buildings Food Services Hotels Retirement Homes Office Buildings Mining Operations Thermal Pump System
Open the catalog to page 1Note: When selecting dimension for storage vessel, determine first storage capacity and select the length of vessel to suit the available space. The resulting diameter is found at the intersection of capacity and lenght lines. For any other capacity not listed and/or other information please contact us. Maximum standard vessel available: 120" (3048 mm) dia. x 30' (9144 mm) long. - One unit multipurpose in the boiler room. - Storage capacity based on actual requirements. - Use of electric valleys under demand charge. - Independent control of water heating , DHW, and glycol mixture. - Cost...
Open the catalog to page 2Technical Specifications SYSTEM COMPONENTS Thermal storage vessel of high-temperature water (non circulating) Unit with 2 exchangers Designed according to ASME Section VIII Div. 1 for 100 PSIG with 1/16 in. Corrosion allowance and 400F. Operating at 52.3 PSIG and 300F maximum. 4 in (100mm) fiberglass insulation with 18GA metal cover epoxy painted provided with 16"x18" manhole, flanges for heating elements and heat exchangesrs, drain connection and screwed connections for all controls. Safety valve to suit. Flanged Heating Elements. Have Incoloy blades at 75w/in2 (11.6W/cm2) dissipation;...
Open the catalog to page 3Application for "Acmetherm" Selection ACMETHERM Hot Water Heaters are designed and manufactured to specific requirements. Our Company offers free engineering assistance in selecting the best solution and most economical design. Please copy or scan this page, fill in the data of your application and e-mail it at info@acmeprod.com, or fax to us at (514) 342-3131, or contact our representative in your area. Acme Engineering Products Inc. Acme Engineering Products Ltd. Montreal, Quebec www.acmeprod.com - info@acmeprod.com - 1 (888) 880-5323 The information provided by this bulletin is a general...
Open the catalog to page 4All Acme Engineering Products Ltd. catalogs and technical brochures
-
CONICAL TEMPORARY STRAINERS
1 Pages
-
Y Strainers
5 Pages
-
FB1 SERIES
2 Pages
-
MGMS Sensing Module
4 Pages
-
CEJW
8 Pages
-
GS
4 Pages
-
TW-ECH
2 Pages
-
40-XP
2 Pages
-
COV-2
2 Pages