DIN Rail Power and Energy Meter
10Pages

{{requestButtons}}

Catalog excerpts

DIN Rail Power and Energy Meter - 1

Three-Phased DIN-Rail Multifunction Meter Revenue grade accuracy: ANSI C12.20 0.5 Class Measurement Canada approved Tamper-proof sealing design approved for revenue applications Wide voltage measurement range, directly measure up to 690V Multiple CT Input Options compatible with any Current Transformers Built-in Modbus and Pulse Output Auto-Wiring check to verify correct installation SunSpec compliance

Open the catalog to page 1
DIN Rail Power and Energy Meter - 2

PRODUCT OVERVIEW The AcuRev 1310 DIN Rail meter combines high performance with ease of integration to provide a cost-effective power and energy monitoring solution. Featuring a built-in LCD display designed to simplify setup and local reading of meter data. While the Modbus-RTU and pulse output communication allows seamless integration with data acquisition systems. KEY FEATURES The AcuRev 1310 Series of three-phase mutli-circuit power and energy meters offer revenue grade accuracy and a wealth of other features, including: • Utility Revenue Grade Accuracy - IEC 62053-22 0.5s Class / ANSI...

Open the catalog to page 2
DIN Rail Power and Energy Meter - 3

UNIVERSAL RATING Voltage: Measuring from 10V to 400VL-N 690VL-L that works with most voltage ratings without a Potential Transformer. Potential transformer ratio configuration supported where PT is used. Frequency: Automatically adapt to 50Hz and 60Hz system without compromising the accuracy, which simplifies design and eliminates international OEM frequency issues. FOUR CHANNEL CT INPUT Accurately measure neutral current with 4th CT and provide residual current measurement. AUTO PHASE-CHECK Designed to automatically check most common wiring mistakes such as CT polarity, voltage and current...

Open the catalog to page 3
DIN Rail Power and Energy Meter - 4

ACUREV 1310 FUNCTIONS COMPARISON Feature Reactive Energy Apparent Energy Power Demand Peak Power Demand Predictive Demand (existing in AcuRev 2000) Current Demand Peak Current Demand Bi-Directional Energy Measurement Active Energy Neutral Current Residual Current Reactive Power Apparent Power Power Factor Active Power Running Time Energy Pulse Output Relay Output (Alarm or Control) Wiring Check Temperature (Internal) Current Transformer (CT) Input I/O Options:

Open the catalog to page 4
DIN Rail Power and Energy Meter - 5

Parameter Accuracy Resolution Range Active Energy 0.5% SPECIFICATIONS Voltage Relay Output Rated Voltage Input Impedance Measurement Frequency Accuracy Stated Current (IN) Start Current Accuracy Max Load Current Isolation Voltage Action Time Mechanical Life Electrical Life Pulse Output Isolation Voltage Load Voltage Load Current Communication Protocol Infrared Communication Infrared Baud Rate Power Supply Power Consumption AECUEbERGY WWW.ACCUENERCY.COM

Open the catalog to page 5
DIN Rail Power and Energy Meter - 6

Typical wiring for 5A/1A Current Input LINE Terminal Block Note: Neutral CT is optional LINE A Auxiliary Power Supply Relay Output Relay output Note: Neutral CT is optional Auxiliary Power + Pulse + RS485

Open the catalog to page 6
DIN Rail Power and Energy Meter - 7

Typical Wiring for RCT/mV/mA Current Input Direct Connection, without PT’s Delta Connection LINE A Note: Neutral CT is optional Note: Neutral CT is optional Note: Neutral CT is optional

Open the catalog to page 7
DIN Rail Power and Energy Meter - 8

Model ORDERING NUMBER ORDERING EXAMPLE AcuRev 1313 Current Input I/O 5A: Field configurable CT X0: No Additional I/O 333: 333mV Input CT X1: 1 Relay Output Please Note: AcuRev 1314 does not support Rogowski coil input for neutral current. Consult Accuenergy Engineering Support for correct configuration. Field-configurable CT input that Directly connect to Rogowski coil suits any industrial and revenue- without integrator or power supply, grade current transformer. ideal for any retrofit applications. 333mV Compatible with any 333mV output current transformer for low cost...

Open the catalog to page 8
DIN Rail Power and Energy Meter - 9

The AcuRev1310 enclosure offers a mounting option for AcuRev1310 Series energy meters that helps protect from tampering and the elements. The enclosure is equipped with DIN rail mounting hardware for easy installation, and a NEMA® 4X rating ensures durability. The swing panel kit and multiple locking options provide additional security from unwanted tampering. RoHS C € COMPLIANT ^ ^ V-X Listed Enviromental Rating: Dimensions: Length Width Height Ingress Protection (EN 60529): Electrical insulation: Halogen free (DIN/VDE 0472, Part 815): UV resistance: Flammability Rating: Glow Wire...

Open the catalog to page 9
DIN Rail Power and Energy Meter - 10

ACCUEN515YMAKE ENERGY USAGE SMARTER tf: 1-877-721-8908 int: +1-416-497-4100 fax: +1-416-497-4130 e: marketing@accuenergy.com ACCUENERGY (CANADA) INC. 2 Lansing Square, Suite 700 Toronto, ON M2J 4P8, Canada

Open the catalog to page 10

All Accuenergy Canada Inc. catalogs and technical brochures