ZYB10 E-T-A P106 40MA RESETABLE THERMAL CIRCUIT BREAKER - 1

Description Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Available in versions for PCB or panel mounting, snap-in or threadneck, or as an integral type. Approved to CBE standard EN 60934 (IEC 934). For higher current ratings see type 1140. Typical applications Motors, transformers, solenoids, printed circuit boards, hand-held machines and appliances. Ordering information Technical data Type No. 104PCB mounting type (-PR), or integral type (-P30/P10) 105snap-in panel mounting 106threadneck panel mounting with hex and knurled nut * 106-M1 threadneck mounting for standard fuseholder cutout * Terminal design P10 blade terminals A6.3-0.8 PR solder terminal pins for PCB mounting (type 104 only) Shunt terminal (optional) A3 same as main terminals (up to In 6 A/3 A max. load) Auxiliary contacts (optional) Sj51 type 104 only Current ratings 0.05...10 A I 106 | - |P30 |-|~1 -| ' | T5a| = ordering example The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. * mounting hardware bulk shipped Please enquire for packaging quantities Standard current ratings and typical internal resistance values Degree of protection operating area IP 40 to IEC 68-2-27, test Ea Corrosion 96 hours at 5 % salt mist, Authority Voltage ratings Current ratings _DC 48 V_0.05...10 A Circuit breakers with -Si51 not approved

Open the catalog to page 1
ZYB10 E-T-A P106 40MA RESETABLE THERMAL CIRCUIT BREAKER - 2

Thermal Overcurrent Circuit Breakers 104/105/106-... Dimensions 9.5 hole for mounting screw M2 usable depth 4.5 mm terminal design for correct stand-off distances 1 terminal design for correct stand-off distances

Open the catalog to page 2
ZYB10 E-T-A P106 40MA RESETABLE THERMAL CIRCUIT BREAKER - 3

Thermal Overcurrent Circuit Breakers 104/105/106-... Dimensions Installation drawings operating area mounting hole operating area mounting area mounting hole operating area

Open the catalog to page 3
ZYB10 E-T-A P106 40MA RESETABLE THERMAL CIRCUIT BREAKER - 4

Thermal Overcurrent Circuit Breakers 104/105/106-... Internal connection diagrams Types 104 105 106 Terminal design polarizing tooth Typical time/current characteristics at +23 °C 5.3 polarizing tooth Trip time in seconds Water splash cover (transparent)/knurled nut assembly (type 106-... only) X 201 285 01 Degree of protection IP 64 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 – Technical information....