2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV
60Pages

{{requestButtons}}

Catalog excerpts

2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 1

Kabeldon cable accessories 52- 420 kV

Open the catalog to page 1
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 3

Cable accessories for XLPE-insulated cables 7.2–42 kV Cable accessories 12–52 kV, PILC cables Cable accessories for XLPE-insulated cables 52–420 kV Universal clamps List of contents – Alphabetical order List of contents – by category Data sheet for determining cable accessories Reference pictures The greyed out sections 2, 3, 4 and 5 are not included in this catalog. ABB Catalog 2014 | Kabeldon cable accessories 1–420 kV |

Open the catalog to page 3
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 4

1/1 | Kabeldon cable accessories 1–420 kV | Introduction

Open the catalog to page 4
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 5

Reasons tor choosing Kabeldon cable accessories 1/5 Introduction | Kabeldon cable accessories 1-420 kV | 1/2

Open the catalog to page 5
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 6

Our factory is situated in Alingsås, Sweden. The production is automated and meets stringent quality and environmental requirements. We work to create safe electrical distribution via power cable networks. To achieve this, we develop, manufacture and market a broad range of cable accessories, switching devices and enclosures. Our business idea “We provide companies that work with electric power with solutions which enable them to joint and connect cables easily and safely, and distribute electricity“. Our main groups of customers are power supply companies, network companies, industrial...

Open the catalog to page 6
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 7

Fundamental technologies 1 We work on the basis of four fundamental technologies within which we have accumulated substantial expertise over many years. 1. Electrical connections The safe and secure transfer of electric current between cable conductors, or between a cable conductor and a device, requires an electrical connection of good quality. We test and develop various methods, but in most cases we use bolt technology, that gives us the possibility of offering complete solutions in line with our philosophy of easy and safe installation. 2. Controlling electrical fields At high voltages...

Open the catalog to page 7
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 8

Reasons for choosing Kabeldon cable accessories 1 A power cable network must be capable of supplying electric power without interruption. If a failure does occur, it is usually the junction points in the network that are at fault, rarely the cable. So it pays to choose cable accessories with care. Unique, long experience Long experience brings great expertise. We have been manufacturing cable accessories for paper-insulated cables for about 100 years. When XLPE-insulated cables began to be used more than 50 years ago, we were involved from the outset. Since then we have always been in the...

Open the catalog to page 8
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 9

1 Professional training The technology of cables and their installation is constantly developing. We offer a broad range of courses in cable technology and cable accessories. Our instructors also take part in our development projects, so you can be sure that they have access to the latest technology. We arrange training programmes and practical exercises in the assembly of cable accessories up to 420 kV. All course participants will receive a diploma or a training certificate after passing a theoretical and practical test. If you would like to know more about the courses, please contact...

Open the catalog to page 9
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 10

1 Definition of voltages Cables and cable accessories are classified according to the voltages at which they operate. A rapid survey at standards all over the world shows that the designations are a little different. However, IEC designations gives a clear picture of used vocabulary. The voltages normally used in this context are: U0 = the rated r.m.s.(root mean square) power-frequency voltage between each conductor and screen or sheath for which cables and accessories are designed. U = the rated r.m.s power-frequency voltage between two different conductors for which the cables and...

Open the catalog to page 10
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 11

1 Voltage range Um 1.2 kV In this voltage range, the function of cable accessories is to provide mechanical protection and insulation. There is no need for controlling the electrical field. IEEE: The currently applicable standards are Std. 48 for terminations covering insulation classes 2.5-765 kV, and Std. 404 for joints rated at 2.5-500 kV. The test voltage for joints is generally lower than for equivalent terminations. In the past, there was no international standard, only national standards. CENELEC therefore produced an international standard, HD 623 S1, which is equivalent to Swedish...

Open the catalog to page 11
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 12

A snapshot of a cable termination manufacture. Research and development are the basis for the manufacturing of our products. Manufacturing of premolded connectors. The different layers are vulcanized together. The premolded cable joints are routine tested after manufacturing. The three layers of the joint are vulcanized together in a unique manufacturing process. Electrical testing of cable termination for 420 kV at our high voltage laboratory. 1/9 | Kabeldon cable accessories 1–420 kV | Introduction

Open the catalog to page 12
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 13

We test and develop electrical connections with reliable bolt connector technology. Testing Kabeldon cable termination APECB 245 P and cable joint JS-A 245 in an independent laboratory. Shortcircuit test, HDC-A. Cycling rigging for testing electrical connections. Testing Kabeldon dry cable termination TD 145 in an independent laboratory. Introduction | Kabeldon cable accessories 1–420 kV |

Open the catalog to page 13
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 14

6/1 | Kabeldon cable accessories 1–420 kV | Cable accessories for XLPE-insulated cables 52–420 kV

Open the catalog to page 14
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 15

Cable terminations Outdoor cable termination Outdoor flexible cable termination, APSEA 52-72 kV 6/7 Outdoor cable termination, APECB 84-420 kV 6/10 Dry outdoor pre-assembled cable termination, TD 145 kV 6/13 Dry plug-in indoor cable termination, CD 145 kV for connection to Cable termination, APEGA 84-420 kV for connection to Earthing kits for cable terminations, JSA, SCK 6/21 Cable joints_ Premolded one-piece cable joint - without screen interruption JS 52-123 kV 6/22 - with screen interruption JX 52-123 kV 6/22 Premolded one-piece cable joint -without screen interruption JS 245 kV 6/26...

Open the catalog to page 15
2014 ? Product catalog ? Kabeldon cable accessories 52?420 kV - 16

Introduction Cable accessories 52–420 kV ABB in Alingsås has long experience in the area of 52–420 kV and has always led the field in research and development. We were among the first in the world to use stress cone technology to control electrical fields. One reason for our success is that we have constantly developed cable accessories for all types of cables. This has given us an experience base that is both broad and deep. We have also developed our accessories to facilitate for optical fiber in power cables, and even integrated cross bonding in cable joints. This involves system...

Open the catalog to page 16

All ABB catalogs and technical brochures

  1. MNS with M10x