OC Cam Switches 10 to 25 Amperes
80Pages

{{requestButtons}}

Catalog excerpts

OC Cam Switches 10 to 25 Amperes - 1

Versatility made simple

Open the catalog to page 1
OC Cam Switches 10 to 25 Amperes - 3

Product overview, features Technical data Rotary cam switches OC, 10...25 Amperes_t[ Ordering information, standard cam switches, the most common applications Motor control switches: Ventilation, reversing, star-delta, pole-change, pumpstart, stop and start switches 28 Ordering information, accessories Protective rear cover, nut spanner tool, adaptor ring, spare key_39 Order code configuration, standard cam switches Options for Standard cam switch configuration 40 Type designation Rotary cam switches OC10...25. standard and customized_57 Dimension drawings Rotary cam switches OC10 and...

Open the catalog to page 3
OC Cam Switches 10 to 25 Amperes - 4

Versatility made simple OC10...25 Amperes CamWeb2 – Best configuration tool It’s powerful, it’s fast, it’s user-friendly Configuration tool CamWeb2 is designed to allow customers to custom-configure cam switches according their needs. –– Laser-printed text for life-long visibility, even in harsh environments –– Configurable switch body offers horizontal or vertical access to terminals High performance cam switches –– New patent-pending contact design guarantees consistent opening times between moving and fixed contacts. This results in higher current performances and a longer life span. ––...

Open the catalog to page 4
OC Cam Switches 10 to 25 Amperes - 5

Versatile mounting options Door Mounting available in 2 versions –– Screw Mounting: multiple fixing points with screws. –– Snap-on Mounting: quick and easy installation which can reduce labor time by up to 5 times. Base Mounting versions are equipped with features that allow screw or DIN rail mounting. ABB’s complete offering ABB offers a wide variety of switches, breakers, control gear, wiring accessories, DIN-rail components and much more A wide range of LV products available from one supplier

Open the catalog to page 5
OC Cam Switches 10 to 25 Amperes - 6

Customized cam switches Design your own cam switch with CamWeb2 CamWeb2 – Best configuration tool It’s powerful, it’s fast, it’s user-friendly Configuration tool CamWeb2 is designed to allow customers to custom-configure cam switches according their needs. –– –– –– –– Configuration of non-standard switches No need to do specifications manually Browser application, no installed software needed With a broad selection of accessories and contact configurations in CamWeb2, there is always a switch suitable for your application Custom-made cam switches designed specifically for you How to use it?...

Open the catalog to page 6
OC Cam Switches 10 to 25 Amperes - 7

Standard and customized cam switches OC Versatile handle selection Suitable Standard handle types according to the ordering code configuration tables. Special handles, gang drive and additional lettering plate selection configurable with Cam-Web2. Nose handles (_N or _M) Nose handles have a degree of protection IP66. Door mounted versions can be snap-on or screw mounted. Snap-on mounted switches are suitable for 22.5 mm door drilling and screw mounted switches have a two (OC10) or four (OC25) hole mounting pattern. For base mounting, the handle can be fixed directly on the switch or on the...

Open the catalog to page 7
OC Cam Switches 10 to 25 Amperes - 8

Standard and customized cam switches OC Versatile handle selection Modular switch handle with front cover (MN) This handle is available only for base-mounted OC25 switches and the handle is mounted directly to the switch. It is light gray and the degree of protection is IP20. The handle can be used with standard 45 mm door or cover cutouts and is suitable for 35 mm dinrail mounting. If 6 contacts or less are used, the switch depth is consistent with other standard 45 mm components, such as miniature circuit breakers. The handles are available in black, gray or red-yellow. They can be used...

Open the catalog to page 8
OC Cam Switches 10 to 25 Amperes - 9

Standard and customized cam switches OC Versatile handle selection Double or triple gang drive These options are available for OC25 and allow a larger number of contacts to be used: up to 2x24 contacts for double (tandem) and up to 3x24 contacts for triple gang drive. Double or triple gang drive switches include an extended nose handle or have the option of an extended padlockable nose handle. The switches can be screw mounted on door or base mounted. For base mounting, the handle is fixed directly on the switch. The front plate size is 66X66 mm and the degree of protection is IP66. Spring...

Open the catalog to page 9
OC Cam Switches 10 to 25 Amperes - 10

Standard and customized cam switches OC How to read contact diagrams Symbol key Contact closed Contact closed without interruption between switch positions Early make, late break contact Contact closed with interruption between switch position Spring return Example Switch with 3 postitions and 2 contacts. Spring return option between “START” and “1”. 1 pole There is a jumper installed between terminals 1 and 3 No contacts are closed in the position”0” Contact 1-2 is closed in position ”1” Contact 1-2 remains closed when moving switch to ”START” position. Contact 3-4 also closes when switch...

Open the catalog to page 10
OC Cam Switches 10 to 25 Amperes - 11

Technical data Rotary cam switches OC 10...25 Amperes Rated insulation voltage j It I Pollution degree 3 j V j 500 j 690 Rated impulse withstand voltage j Uimp j j kV j 2.5 j 4 Rated thermal current ;lth ; jA j 10 j 25 Rated conditional short circuit current i I (r.m.s.) ! I kA i 111 i 71: Max back-up fuse link j j |A j 10 j 25 Rated short time withstand current j r.m.s.-value low Ms iA i 120 j 300 Conditional short circuit current i I i 500 V i kA i 3 i - Rated operational current j AC-21A 1 and 3-phase i 400 V IA j 10 | 25 Rated operational current, DC-21A M-contact in series j 48 V iA M0...

Open the catalog to page 11
OC Cam Switches 10 to 25 Amperes - 12

Technical data Rotary cam switches OC 10...25 Amperes Power loss per contact - at rated lth j Standard contacts j j W i < 0.6 j < 1.8 Contact resistance j Standard contacts i j Ohms i < 0.004 j < 0.003 Power loss per contact - at rated lth j Gold contacts j jW j 0.4 ; < 1.8 Contact resistance i Gold contacts \ j Ohms | < 0.006 | < 0.003 Minimum switching capacity j Gold contacts i i mA j 5 j 5 i Gold contacts j \ V AC/DC ! 5 I 5 Terminals j Max cable cross section, solid/ ! I mm2 j 0.5...1.5 M.5...4 Mechanical endurance51 j 8 Contacts and less i i Number j 500 000 j 500 000 Temperature j...

Open the catalog to page 12

All ABB Smart Power catalogs and technical brochures