Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1
20Pages

{{requestButtons}}

Catalog excerpts

Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 1

Maximum safety and easy installation Arc fault detection devices with integrated MCB and RCBO © • Complete protection against arc faults, overcurrent and earth faults • Easy cross-wiring and installation • Supply possible from both top and bottom side • Family feeling in the System pro M compact® range • LED for an easy troubleshooting of the network • equipped also with memory recall function

Open the catalog to page 1
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 2

— Maximum safety in buildings Extended fire protection in the electrical installation with AFDDs Comprehensively protect people, irreplaceable goods and buildings – easier, better, safer. Extended fire protection in the electrical installation with ABB’s arc fault detection devices (AFDD) S-ARC1 and DS-ARC1 — 01 The S-ARC1 and DS-ARC1 reliably protect against arc faults. Each year over two million fires erupt all over Europe. More than one third of these due to faults in the electrical installation which prevailingly occur as a result of dangerous arc faults. The best comprehensive...

Open the catalog to page 2
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 3

P R OTECT I ON FOR P EOP L E AN D I RRE PL AC E ABLE GOODS — Protection for people and irreplaceable goods Maximum safety in all kinds of applications The majority of fires in buildings are caused by faults in the electrical installation. These fires are mainly caused by dangerous arc faults. The solution: S-ARC1 and DS-ARC1. — 01 Areas of application for AFDDs Bedrooms and common rooms in nurseries — 02 Areas of application for the AFDDs Paper manufacturing plants, printers — 03 Causes of fire in Germany (2015) S-ARC1 and DS-ARC1 provide maximum safety in all buildings, thus protecting...

Open the catalog to page 3
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 4

MAXIMUM SAFETY WITH EASY INSTALLATION Early detection for extended protection against fires AFDDs close the protection gap against arc faults 01 Series arc faults occur when a conductor is disrupted. 02 Parallel arc faults occur between external conductors and protection of neutral conductors. 03 The ABB's AFDDs detects arc faults against ground. 04 A damaged line and insulation can lead to a fire risk through a series arc fault. 05 Loose contact in an incorrectly connected flush-mounted outlet can lead to a fire risk through a serial arc fault 06 Scorched faulty installation or...

Open the catalog to page 4
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 5

EAR LY DET ECT I ON FOR EX TEN DED PROTE C TION AGAINST FIRE S — 01 Security in buildings with flammable materials With AFDDs many hazards triggered by disruptions in the electrical installation are detected in advance. Thus, the existing gap of protection against arc faults is closed, leading to complete safety in buildings for persons, investments and irreplaceable goods. In case the overvoltage level exceeds 275 V, both S-ARC1 and DS-ARC1 are equipped with an overvoltage protection. In addition, DS-ARC1 also offers protection against earth fault currents. With S-ARC1 people and valuable...

Open the catalog to page 5
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 6

MAXIMUM SAFETY WITH EASY INSTALLATION Protection against: • Overcurrent (short circuits, overload) Protection against: • Earth faults currents • Earth arc faults Protection against: • Overcurrent (short circuits, overload) • Earth fault currents • Earth arc faults

Open the catalog to page 6
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 7

P R OTECT I ON AGAI N ST ARC FAULTS — Different levels of protection Complete protection offered by AFDD 01 S-ARC1 AFDD with integrated MCB — 01 Areas of application for AFDD Wooden houses, museums, galleries and architectural monuments — 02 Areas of application for AFDD Workshops for wood processing and carpentry Protection against: • Overcurrent (short circuits, L overload) • Series, parallel and earth arc faults Maximum Protection 02 DS-ARC1 AFDD with integrated RCBO Protection against: • Overcurrent (short circuits, overload) • Earth fault currents • Series, parallel and ear

Open the catalog to page 7
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 8

— Best solution: S-ARC1 and DS-ARC1 Product overview ABB’s AFDDs S-ARC1 and DS-ARC1 protect people and irreplaceable goods from fire hazards by early detecting arc faults in the electrical installation and disconnecting the affected circuit. They are available as AFDD with integrated MCB (S-ARC1) and AFDD with integrated RCBO (DS-ARC1). S-ARC1 is the 1P+N arc fault detection device with integrated miniature circuit breaker (MCB) in 6 kA AFDD overview Test pushbutton and self test Orange test push button to verify the correct functioning of AFDD. White test push button to verify the correct...

Open the catalog to page 8
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 9

DS-ARC1 is the new 1P+N AFDD with an integrated residual current circuit breaker with over-current protection (RCBO) in 6 kA and 10 kA breaking capacity. In only three-module width, DS-ARC1 series offers a complete protection against arc faults and overvoltage, reducing the risk of fire. The integrated RCBO is adding protection against overcurrent as function of the integrated MCB also available in S-ARC1 and earth fault current: compact solution for a complete protection of people and valuable assets. Connection possible both from top and bottom side. Easy to install Twin terminals for...

Open the catalog to page 9
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 10

MAXIMUM SAFETY WITH EASY INSTALLATION 01 The LED function in detail 02 LED colors: off, green, red 03 Contact position indicator (CPI) in detail S-ARC1 and DS-ARC1 are equipped with LED function monitoring, which shows the current status of the device and identifies the cause of the tripping. Maintenance time can therefore be reduced thanks to an easier troubleshooting of the network. During standard operating mode (toggle in ON position), the LED is green. When the toggle is on OFF position, the LED is OFF. Easy fault analysis In the case of a fault, the LED displays the different fault...

Open the catalog to page 10
Maximum safety and easy installation AFDDs S-ARC1 and DS-ARC1 - 11

RELI ABLE TECH N OLOGY — 04 The earth fault indicator — 05 Recall of last LED indication Earth fault indicator DS-ARC1 is equipped with an earth fault indicator to identify earth fault trips. A blue flag on the toggle will appear making the troubleshooting easier while reducing the downtime for maintenance operations. In case of earth fault trip, after reclosing the toggle, the LED becomes green. Earth fault indicator Blue flag on the 2/1 N toggle to identify earth fault tripping Recall and clearing function: new feature introduced S-ARC1 and DS-ARC1 allow to recall the last LED indication...

Open the catalog to page 11

All ABB Smart Power catalogs and technical brochures

  1. Bus couplers

    3 Pages

  2. SlimLine XR

    52 Pages

  3. SACE Emax 2

    277 Pages

  4. TruOne

    68 Pages

  5. OFAM/ OFAA

    2 Pages

  6. SACE Tmax XT

    8 Pages

  7. ABB Division

    17 Pages

  8. V400

    2 Pages

  9. V16

    2 Pages

  10. P42E

    2 Pages

  11. Nightstar

    2 Pages

  12. EasyLine XLP

    31 Pages