1. Catalogs
  2. ABB Smart Power
  3. Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types

Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types

Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types
1 / 60 PagesView full catalog

Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types

Product catalog summary
Overview: The document provides comprehensive information on DIN-type High Rupturing Capacity (HRC) fuse links, specifically focusing on gG and aM types, suitable for over-current and short-circuit protection in industrial applications. It covers specifications for different voltage levels (500V and 690V) and includes technical data, dimension drawings, and ordering information.
Value Propositions: ABB's fuse links are engineered for reliability in demanding environments, offering robust protection for both general and motor applications. They ensure maximum fault protection and are designed for continuous operation with enhanced safety features.
Specifications: Detailed specifications for gG and aM type fuse links are provided, including rated voltage, current, power loss, and type codes. The document also includes ordering information with specific order codes and delivery batch details.
Technical Data: The document includes crucial technical data such as time-current characteristics, cut-off current characteristics, and pre-arcing and operating I²t characteristics, which are essential for assessing the performance and suitability of the fuse links in various scenarios.
Dimension Drawings: Dimension drawings are provided to assist in the correct installation and application of the fuse links, detailing the physical dimensions for different sizes and types.
Ordering Information: Comprehensive ordering information is provided for both gG and aM types, including type codes, order codes, and delivery batch sizes, which is vital for procurement and inventory management.
Recommendations: For motor protection, aM fuse links are recommended due to their economical and reliable protection capabilities. The document also suggests the use of electronic fuse monitors for enhanced protection and control.
Conclusion: ABB's DIN-type HRC fuse links are versatile and reliable, suitable for a wide range of industrial applications. The document serves as a thorough guide for selecting and ordering the appropriate fuse links based on specific requirements.
Additional Information: The document concludes with a disclaimer about potential technical changes and rights reserved by ABB Oy, along with contact information and a reference to the ABB website for further details.
See more

Catalog excerpts

Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-3

DIN-type HRC fuse links Ordering information Fuse links, DIN-type, gG Fuse links, DIN-type, aM Technical data Cut-off current chrasteristics 044  – 051 Pre-arcing and operating I2t charasteristics 0

 Open the catalog to page 3
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-5

— DIN-type HRC-fuse link range 2...1250 A, 500 V and 690 V ABB`s gG fuse links have proven themselves to be suitable for a number of applications, from over-current and short-circuit protection of lines to short-circuit protection of semiconductor and other equipment as well as protection of DC circuits. For motor protection, we recommend to use aM fuse links. The aM fuse links give economical and reliable protection. ABB fuse links for demanding industrial environments are available to be used in the protection of general as well as motor applications. — Continuous operation The dual indicating...

 Open the catalog to page 5
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-6

— DIN-type HRC fuse links, gG OFAF_H and OFAA_GG — DIN-type HRC fuse links, aM OFAF_AM and OFAA_AM_

 Open the catalog to page 6
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-7

ORDERING INFORMATION general application OFAF_H_, _<500V NH-size Rated Rated Power Type code Order code Delivery Weight voltage current loss batch

 Open the catalog to page 7
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-8

FUSEGEAR DIN-TYPE HRC-FUSE LINKS general application OFAF_H <500V NH-size Rated Rated Power Type code Order code Delivery Weight voltage current loss batch

 Open the catalog to page 8
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-9

ORDERING INFORMATION HRC fuse links, gG, general application OFAA_GG NH-size Rated Rated Power Type code Order code Delivery Weight voltage current loss batch

 Open the catalog to page 9
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-10

FUSEGEAR DIN-TYPE HRC-FUSE LINKS general application OFAA_GG <690V NH-size Rated Rated Power Type code Order code Delivery Weight voltage current loss batch

 Open the catalog to page 10
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-11

ORDERING INFORMATION HRC fuse links for motor protection, aM, OFAF_AM rOFAFOOAM NH-size Rated Rated Power Type code Order code Delivery Weight voltage current loss batch

 Open the catalog to page 11
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-12

FUSEGEAR DIN-TYPE HRC-FUSE LINKS HRC fuse links for motor protection, aM, OFAF_AM NH-size Rated Rated Power Type code Order code Delivery Weight voltage current loss batch

 Open the catalog to page 12
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-13

ORDERING INFORMATION HRC fuse links for motor protection, aM, OFAA_AM NH-size Rated Rated Power Type code Order code Delivery Weight voltage current loss batch

 Open the catalog to page 13
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-14

FUSEGEAR DIN-TYPE HRC-FUSE LINKS Fuse replacement handles Remark: Fuse size 4a, fuse replacement with the cover of switch fuse OS1250 or fuse base OFAX4. Suitable for DIN-fuse link size Type code Order code Units / Weight type pcs kg Electronic fuse monitor Suitable for 1- and 3-phase circuits. Rated voltage Type code Order code Units / Weight type V pcs kg Crimp terminals for connecting fuse monitor to the switch fuse types OS Suitable for switch fuse Flat terminal size Type code Order code Units / Weight type pcs kg

 Open the catalog to page 14
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-15

TECHNICAL DATA Technical data according to IEC 60269 The fuse links are tested to the following short circuit ratings. Current range OFAF_H 500 2-100 Size Fuse type Breaking capacity OFAF_H OFAA_GG OFAF_H _OFAA_GG Size Fuse type Current range OFAF_AM Size Fuse type Breaking capacity OFAF_AM _OFAA_AM Utilization category gG aM gG aM gG: Used in general protection of cables and lines in installati

 Open the catalog to page 15
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-16

— Time-current characteristics HRC fuse links gG — Time-current characteristics, 500 V, gG-fuse links OFAF_H_, sizes 000-00

 Open the catalog to page 16
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-17

TIME- CURRENT CHAR AC TERISTICS — Time-current characteristics HRC fuse links gG — Time-current characteristics, 500 V, gG-fuse links OFAF_H_, sizes 0-1

 Open the catalog to page 17
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-18

— Time-current characteristics HRC fuse links gG — Time-current characteristics, 500 V, gG-fuse links OFAF_H_, sizes 2-3

 Open the catalog to page 18
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-19

TIME- CURRENT CHAR AC TERISTICS — Time-current characteristics HRC fuse links gG — Time-current characteristics, 500 V, gG-fuse links OFAF_H_, size 4/4a

 Open the catalog to page 19
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-20

— Time-current characteristics HRC fuse links gG — Time-current characteristics, 690 V, gG-fuse links OFAA_GG_, sizes 000-00

 Open the catalog to page 20
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-21

TIME- CURRENT CHAR AC TERISTICS — Time-current characteristics HRC fuse links gG — Time-current characteristics, 690 V, gG-fuse links OFAA_GG_, sizes 0-1

 Open the catalog to page 21
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-22

— Time-current characteristics HRC fuse links gG — Time-current characteristics, 690 V, gG-fuse links OFAA_GG_, sizes 2-3

 Open the catalog to page 22
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-23

TIME- CURRENT CHAR AC TERISTICS — Time-current characteristics HRC fuse links gG — Time-current characteristics, 690 V, gG-fuse links OFAA_GG_, size 4/4a

 Open the catalog to page 23
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-24

— Time-current characteristics HRC fuse links aM — Time-current characteristics, 500 V, aM-fuse links OFAF_AM_, sizes 000-00

 Open the catalog to page 24
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-25

TIME- CURRENT CHAR AC TERISTICS — Time-current characteristics HRC fuse links aM — Time-current characteristics, 500 V, aM-fuse links OFAF_AM_, sizes 0-1 aM 500V, 0

 Open the catalog to page 25
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-26

— Time-current characteristics HRC fuse links aM — Time-current characteristics, 500 V, aM-fuse links OFAF_AM_, sizes 2-3 aM 500V, 2

 Open the catalog to page 26
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-27

TIME- CURRENT CHAR AC TERISTICS — Time-current characteristics HRC fuse links aM — Time-current characteristics, 500 V, aM-fuse links OFAF_AM_, size 4/4a

 Open the catalog to page 27
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-28

— Time-current characteristics HRC fuse links aM — Time-current characteristics, 690 V, aM-fuse links OFAA_AM_, sizes 000-00

 Open the catalog to page 28
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-29

TIME- CURRENT CHAR AC TERISTICS — Time-current characteristics HRC fuse links aM — Time-current characteristics, 690 V, aM-fuse links OFAA_AM_, sizes 1-2 aM 690V, 1

 Open the catalog to page 29
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-30

— Time-current characteristics HRC fuse links aM — Time-current characteristics, 690 V, aM-fuse links OFAA_AM_, sizes 3-4/4a

 Open the catalog to page 30
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-31

— Cut-off current characteristics HRC fuse links gG — Current limitation, 500 V, gG-fuse links OFAF_H_, sizes 000-00 gG 500V, 000 105 Cut-off current limited by fuse link ic/A (peak) Cut-off current limited by fuse link ic/A (peak)

 Open the catalog to page 31
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-32

— Cut-off current characteristics HRC fuse links gG — Current limitation, 500 V, gG-fuse links OFAF_H_, sizes 0-1 gG 500V, 0 Cut-off current limited by fuse link ic/A (peak) Cut-off current limited by fuse link ic/A (peak)

 Open the catalog to page 32
Fusegear DIN-type HRC-fuse links, 2...1250 A gG- and aM-types-33

— Cut-off current characteristics HRC fuse links gG — Current limitation, 500 V, gG-fuse links OFAF_H_, sizes 2-3 gG 500V, 2 105 Cut-off current limited by fuse link ic/A (peak) Cut-off current limited by fuse link ic/A (peak)

 Open the catalog to page 33

All ABB Smart Power catalogs and technical brochures

  1. Bus couplers

    3  Pages

  2. SlimLine XR

    52  Pages

  3. SACE Emax 2

    277  Pages

  4. TruOne

    68  Pages

  5. OFAM/ OFAA

    2  Pages

  6. SACE Tmax XT

    8  Pages

  7. ABB Division

    17  Pages

  8. V400

    2  Pages

  9. V16

    2  Pages

  10. P42E

    2  Pages

  11. Nightstar

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.