EasyLine XLP
31Pages

{{requestButtons}}

Catalog excerpts

EasyLine XLP - 1

Fuse Switch Disconnector 1-2-3-4 pole

Open the catalog to page 1
EasyLine XLP - 3

Electronic Fuse Monitoring Busbar Adapters Cable clamps & bolts Technical Data Ordering tables Dimensional drawings

Open the catalog to page 3
EasyLine XLP - 4

Fuse protection - Easy and reliable The fuse is a superior short circuit protection element regarding the maximum allowed cut-off current (peak let through current) and energy value. This is more important the higher the voltage and prospective fault levels are. The SlimLine switch disconnector fuse fulfil the highest requirements for modern switch fuses with a total safety concept. The switch fuses are tested according to the EN 60947-3 standard with more stringent requirements for isolation, making, performance and safety.The fuse rails are tested according to IEC 60269-2-1. The melting...

Open the catalog to page 4
EasyLine XLP - 5

The EasyLine family consist of 1, 2, 3 and 4 pole solutions, rated from 100A - 630A. All units are applicable for AC Voltage, and the 1-pole and 2-pole range are also rated for DC voltage. In addition to be used as single apparatus, the 3-pole range from size 00 to size 3 (160A - 630A) are also designed to be used in distribution systems by use of a busbar adapter for easy installation. The Busbar adapters are available for 40mm, and 60mm distance in-between centre of the phases for each busbarsystems. The whole EasyLine range got a sturdy, uniform design that is operator friendly and safe...

Open the catalog to page 5
EasyLine XLP - 6

All the XLP cable terminals can be delivered with integrated bolts for cable lugs or with integrated bridge clamps (BC) for easy direct cable connection. Compact XLP000 Typetested according to EN60947-3 Fullfills BGV A2 Easy to recycle / EN14001 standards Quick-make operation device Integrated IP20 cable termination IP30 degree of protection from the front Replacement compatible to similar types in the market Voltage measuring from the front V-0 plastic materials Easy to install Easy to operate Functional and modern design Sturdy design High personal safety Wide range of cable terminals and...

Open the catalog to page 6
EasyLine XLP - 7

Rated operational voltage: 220VDC / -690VAC Rated operational current: 160 - 630A Micro auxillary switches, 1 or 2 pcs per pole Single cable shroud per phase Cable clamps Front frames Padlocking Sealing facility UPS: Uninterruptible Power Supply, used for the power supply for computer/servers, storage devices, communication network systems, industry control systems, etc. Telecom Power Supplies. General protection in smaller distribution panels using 1-pole or 2-pole configurations AC or DC.

Open the catalog to page 7
EasyLine XLP - 8

Rated operational voltage: 220 - 440VDC / -690VAC Rated operational current: 160 - 630A Micro auxillary switches, 1 or 2 pcs per pole Single cable shroud per phase Cable clamps Front frames Padlocking Sealing facility UPS: Uninterruptible Power Supply, used for the power supply for computer/servers, storage devices, communication network systems, industry control systems, etc. Telecom Power Supplies. General protection in smaller distribution panels using 1-pole or 2-pole configurations AC or DC.

Open the catalog to page 8
EasyLine XLP - 9

XLP000 • Compact design for NH 00 compact fuses up to 100 A (width = 21mm) • Modern integrated cable clamps for 1,5 - 35 mm² cables • Integrated cable shrouds IP 20 • Snap on for DIN rail mounting (accessory) • Front frames for 1 - 3 apparatus (accessory) • Micro auxiliary switches, 1or 2 pcs (accessory) • Sealing facility Sealing facility Front frames for 1-3 apparatuses Voltage measurement Integrated cable clamps for 1,5 - 35 mm² cables

Open the catalog to page 9
EasyLine XLP - 10

XLP00 • Electronic fuse monitoring (EFM) • Micro auxilliary switches, 1 or 2 pcs • Auxilliary switches, 1 NO or 1 NC acc. to IEC 60947-5-1 • Cable shrouds • Front frames for 1 - 3 apparatus • Wide range of cable terminal clamps (See page 13 and 14) • Kit for double DIN rail mounting • Adapter for 40 and 60 mm busbar distance • Padlocking facility • Sealing facility Padlocking and Sealing facilities Electronic fuse monitoring showing detail for remote signaling Micro auxiliary switch on the sides. Auxiliary switch NO or NC in the front Cable shrouds 7

Open the catalog to page 10
EasyLine XLP - 11

XLP1, XLP2 and XLP3 • Electronic fuse monitoring (EFM) • Micro auxilliary switches, 1 or 2 pcs • Auxilliary switches, 1 NO or 1 NC acc. to IEC 60947-5-1 • Cable shrouds • Front frames • Wide range of cable terminal clamps (See page 13 and 14) • Adapter for 40mm (only XLP!) and 60mm busbar distance • Padlocking facility • Sealing facility

Open the catalog to page 11
EasyLine XLP - 12

Rated operational voltage: 550VAC Rated operational current: 160 - 630A Micro auxillary switches, 1 or 2 pcs per pole Single cable shroud per phase Cable clamps Front frames Padlocking Sealing facility General fuse protection in 4-pole power supply networks with switching neutral. Secondary power generators from public networks

Open the catalog to page 12
EasyLine XLP - 13

Electronic Fuse Monitoring 3-pole 1SEB000018 The Electronic Fuse Monitoring (EFM) is a fuse blown indication device. The EFM unit has an integrated potentional free relay (1NO, 1NC) for remote signal/alarm. It will be automatically reset after the blown fuse has been replaced and the green LED turns on again. The matrix below show all possible cases of indication Fuse status Relay contacts NO contact 13, 14 Green Fuses BLOWN Fuses BLOWN Power supply to the EFM unit from phase L2 and L3 The fuse monitor is connected to the gripping lugs of the fuses. NOTE : • NH fuses with insulated gripping...

Open the catalog to page 13
EasyLine XLP - 14

7 60mm busbar system Designed for 60 mm busbar distance XLP00 and XLP1 use busbar Cu/Al 5 or 10mm x 10-30mm. 3 pieces of distance shoes for 5 mm busbars are included with the adapter. For XLP2 and XLP3 use busbar Cu/Al 5-10mm x 10-30mm. The adapters are available for cable connection above (A) or cable connection below (B). The SF-60 Busbar system features Busbar width Busbar thickness Centre distance between busbars Cable connection supply module Cable connections Distribution system for standard Busbars type SF-60 The busbar system type SF-60 is designed to take busbars of different cross...

Open the catalog to page 14
EasyLine XLP - 15

Busbar Adapters 40mm for XLP00 and XLP1 40mm busbar system Cu 12 x 5mm or 12 x 10mm. Adapter 95 mm depth to busbars: A 40/95 40 mm Busbar system for Striebel & John switchboards Specially designed for the Striebel & John Busbar system 250A and 360A. Cu 12x5 or 12x10 mm. Adapter 75 mm depth to busbars, cable connection below: A 40/75 Adapter 120 mm depth to busbars, cable connection below: A 40/120

Open the catalog to page 15

All ABB Smart Power catalogs and technical brochures

  1. Bus couplers

    3 Pages

  2. SlimLine XR

    52 Pages

  3. SACE Emax 2

    277 Pages

  4. TruOne

    68 Pages

  5. OFAM/ OFAA

    2 Pages

  6. SACE Tmax XT

    8 Pages

  7. ABB Division

    17 Pages

  8. V400

    2 Pages

  9. V16

    2 Pages

  10. P42E

    2 Pages

  11. Nightstar

    2 Pages