Catalog excerpts
— EMERGI-LITE DALI emergency lighting Integration for safe monitoring in smart buildings
Open the catalog to page 1— DALI emergency lighting from ABB can easily provide a safe and reliable solution to meet smart building emergency lighting requirements.
Open the catalog to page 2Product applications 006– 007 Why use DALI with emergency lighting? 008– 009 Safety of emergency lighting 010– 017 DALI compatible luminaires Testing & monitoring ABB DALI emergency lighting control system 024 – 025 ABB Elkay 026-027 Standards 028-029 Summary 030
Open the catalog to page 3— Introduction Product applications — 01 Office corridor — 02 Facility managers office — 03 Open plan office — 04 Outdoor area Visitor’s parking Office Cleaning cupboard Mens toilet Ladies toilet Reception Lobby Disabled toilet Facility managers office Open plan office Directors parking Control panel Serenga 2 downlighter Guideway 22 mtr / 32 mtr Aqualux Staff entran
Open the catalog to page 4Open plan office Meeting room Fire exit Delivery bays
Open the catalog to page 5DALI - WHY USE DALI WITH EMERGENC Y LIGHTING? — DALI emergency lighting Why use DALI with emergency lighting? Regular system checks must be carried out to guarantee that any emergency lighting system is fully operational. Emergency lighting with DALI constantly monitors the system, storing reports of any failures or issues and ensuring that the system is 100 percent healthy for the maximum time possible. The health of building occupants is assured, and automatic monitoring reduces maintenance costs. — 01 Emergency lighting can be controlled and monitored via DALI for maximum safety in all...
Open the catalog to page 7— DALI emergency lighting Safety of emergency lighting It has never been more important to ensure the safety of a building, because ensuring safety requires full knowledge that the emergency lighting is fully operational and healthy. As DALI is a two-way communication protocol, the central control can send commands to the luminaire and they will send back information to the control system. DALI emergency is an extension of the DALI protocol, allowing for monitoring of the status of emergency fittings from a touch screen. Proven DALI technology is specific for emergency lighting. Its a...
Open the catalog to page 8DALI EMERGENC Y - SAFET Y OF EMERGENC Y LIGHTING Power Dali bus The emergency lighting package consists of: • ABB luminaires: Exit signs and escape routes self-contained • ABB control panel with emergency lighting function for test and monitoring solutions fo
Open the catalog to page 9— DALI control unit (DCU) Productivity & reliability DALI emergency lighting control panel • Ensuring building occupant safety • Touch screen to control, test and monitor emergency lighting • Simple to group and easy to install — Control unit Input voltage Lamp type DALI emergency control unit Power consumption Operation / (VA/W) duration (hrs) Environment Weight temp. (oC) (kg) 0 - 50 Note. The manual, pre-commissioning documents, device location record sheet, test record sheet and download software for spreadsheet are available on the ABB low voltage website DALI bus power supply 12V DC...
Open the catalog to page 10DALI EMERGENCY LIGHTING - PRODUCT SPECIFICATION AND DATA Escape route signalisation • Compatible with DALI control unit to control, test & monitor emergency lighting • Clearly visible in daylight - 500 cd/m2 • Uniform light distribution • In harmony with interior spaces • Frameless legend design 'So 301® Luminaire Order code DAEGR3LS1-S22 DAEGR3LS1-S32 DAEG3LS1-S22 DAEG3LS1-S32 Power consumption Operation / Environment Weight Description Input voltage Lamp type (VA/W) duration (hrs) temp. (°C) (kg) Includes back to wall mounting accessory as standard. 60 hrs charge at first...
Open the catalog to page 11DALI EMERGENCY LIGHTING - INTEGRATION FOR SAFE MONITORING IN SMART BUILDINGS Escape route lighting • Compatible with DALI control unit to control, test & monitor emergency lighting • Injection moulded - high grade polycarbonate body and geartray of aluminium die cast • Specially designed lens for optimised light distribution • Modular, First-Fix installation Power consumption Operation / Environment Weight Order code Description Input voltage Lamp type (VA/W) duration (hrs) temp. (°C) (kg) Interchangeable lenses are available. Maintained and non maintained Order code...
Open the catalog to page 12DALI EMERGENCY LIGHTING - PRODUCT SPECIFICATION AND DATA Aqualux Durable & high performance Escape route signalisation • Compatible with DALI control unit to control, test & monitor emergency lighting • Attractive aluminium modular enclosure • Clear polycarbonate broad delivery diffuser Description AQUALUX 3W LED DALI M3 Power consumption Operation / Environment Weight Input voltage Lamp type (VA/W) duration (hrs) temp. (°C) (kg) Pictogram EEJ oa RE RE rm □ Order code Description OW/BCM Ceiling bracket, vertical mount OW/BWA Wall bracket, angled mount
Open the catalog to page 13— Ovano Productivity & reliability Escape route signalisation • Compatible with DALI control unit to control, test & monitor emergency lighting • Plug and play, maintained and non-maintained in one • Compact and decorative design Input voltage Lamp type 220-240 Vac, 50 Hz Environment Weight temp. (oC) (kg) 0.66 * Configurable pictograms included Maintained and non maintained Ensure 3cm clearance above product when wall mounting
Open the catalog to page 14DALI EMERGENCY LIGHTING PRODUCT SPECIFICATION AND DATA Ovano Productivity & reliability Escape route signalisation • Compatible with DALI control unit to control, test & monitor emergency lighting • Plug and play, maintained and non-maintained in one • Compact and decorative design Power consumption Operation / Environment Weight Input voltage Lamp type (VA/W) duration (hrs) temp. (°C) (kg) * Configurable pictograms included Maintained and non maintained
Open the catalog to page 15— Ovano Productivity & reliability Escape route signalisation • Compatible with DALI control unit to control, test & monitor emergency lighting • Plug and play, maintained and non-maintained in one • Compact and decorative design Input voltage Lamp type 220-240 Vac, 50 Hz Environment Weight temp. (oC) (kg) -5 - 45 * Configurable pictograms included Maintained and non maintained
Open the catalog to page 16All ABB Smart Power catalogs and technical brochures
-
ABB AbilityTM Smart Sensor
12 Pages
-
Bus couplers
3 Pages
-
SlimLine XR
52 Pages
-
SACE Emax 2
277 Pages
-
Rotary cam switches OC10...25
80 Pages
-
TruOne
68 Pages
-
Switch-disconnectors
192 Pages
-
OFAM/ OFAA
2 Pages
-
SACE Tmax XT
8 Pages
-
YO-YC Test unit
5 Pages
-
Case study. PRAMAC
4 Pages
-
Installation contactors
32 Pages
-
Softstarter PSR, PSE and PSTX
68 Pages
-
SNK Series Terminal Blocks
8 Pages
-
Blackburn Storm Safe
4 Pages
-
Twist Tail Brochure
2 Pages
-
PMA - Automation Products
24 Pages
-
Superstrut SilverGalv
2 Pages
-
ABB Elkay EasyDALI brochure
20 Pages
-
Pacific Intertie
2 Pages
-
ABB Division
17 Pages
-
ABB HVDC Classic
24 Pages
-
Switches for PV application
108 Pages
-
V400
2 Pages
-
V16
2 Pages
-
P42E
2 Pages
-
Nightstar
2 Pages
-
ROYCE THOMPSON
4 Pages
-
Guideway & Serenga 2
28 Pages
-
Analog signal converters
28 Pages
-
Switch fuses OS and OSM
116 Pages
-
SNK terminal blocks global catalog
236 Pages
-
OC Cam Switches 10 to 25 Amperes
80 Pages
-
EasyLine XLP
31 Pages
-
Tmax UL/CSA Technical Catalog
288 Pages