Analog signal converters
28Pages

{{requestButtons}}

Catalog excerpts

Analog signal converters - 1

Analog signal converters Product group picture 273 Catalog 2016 | Electronic relays and controls | 2CDC 110 004 C0210

Open the catalog to page 1
Analog signal converters - 2

Analog signal converters Analog signal converters Ordering details - RTD converters 4/6 DIP switch settings, Dimensional drawings 4/9 Technical diagr., Connection diagr., Dimensional drawings 4/27 2CDC 110 004 C0210 | Electronic relays and controls | Catalog 2016 274

Open the catalog to page 2
Analog signal converters - 3

Analog signal converters Overview Applications for analog signal processing and correct solution using CC-E and CC-U converters 0-10 V Nearly every process includes a control system that receives data by means of analog signals and then evaluates the data and sets the respective parameters correspondingly. When transmitting analog signals numerous problems may arise which can disturb or even block an ideal behavior of the process. Below we have listed some processing problems together with the respective solutions to solve these problems: Controller e.g. AC500 1. Analog signal converter...

Open the catalog to page 3
Analog signal converters - 4

Analog signal converters - CC-E range Benefits and advantages 1 Terminals M, K, J, H, G 2 Terminal explanation 3 Adjustment of gain 4 Adjustment of offset 4 Indication of operational states U - control supply voltage applied CC-E range – – Universally configurable devices and single-function devices – – Adjustment and operating elements on the front side – – Safe operation by electrical 3-way isolation – – Unambiguous and clear connecting terminal markings Conversion, measurement and separation of – – Standard signals (0-5 V, 0-10 V, 0-20 mA, 4-20 mA) – – Temperature signals of RTD sensors...

Open the catalog to page 4
Analog signal converters - 5

Analog signal converters - CC-E range Ordering details - Standard signal converters Ordering details - Standard signal converters Supply voltage range Input signal Output signal Order code loop powered B 1604 Class I, Div.2 (universal device) CC-E-I/I-1 has 1 channel, CC-E-I/I-2 has 2 channels 277 Catalog 2016 | Electronic relays and controls | 2CDC 110 004 C0210

Open the catalog to page 5
Analog signal converters - 6

Analog signal converters - CC-E range Ordering details - RTD converters Ordering details - RTD converters Supply voltage range Input signal Output signal Order code B 1604 Class I, Div.2 (universal device) 2CDC 110 004 C0210 | Electronic relays and controls | C

Open the catalog to page 6
Analog signal converters - 7

Analog signal converters - CC-E range Ordering details - Thermocouple converters Ordering details - Thermocouple Converters Supply voltage range Input signal Output signal Order code B 1604 Class I, Div.2 (universal device) 279 Catalog 2016 | Electronic relays and controls | 2CDC 110 004 C0210

Open the catalog to page 7
Analog signal converters - 8

Analog signal converters - CC-E range Ordering details - Measuring converters Ordering details - Measuring Converters Supply voltage range Output signal Order code Input signal B 1604 Class I, Div.2 (universal device) for sinusoidal currents 2CDC 110 004 C0210 | Electronic relays and controls | Catalog 2016

Open the catalog to page 8
Analog signal converters - 9

Analog signal converters - CC-E range DIP switch settings, Dimensional drawings CC-E/STD, CC-E x/x (universal devices) Select input range by terminals Connected lines Used terminals Terminal marking Connected lines Used terminals Terminal marking Dimensional drawings

Open the catalog to page 9
Analog signal converters - 10

Analog signal converters - CC-E range Wiring instructions CC-E/STD, CC-E x/x (universal devices)

Open the catalog to page 10
Analog signal converters - 11

Analog signal converters - CC-E range Technical data Type Input circuits - Analog inputs CC-E/STD / CC-E x/x Current Voltage CC-E/RTD 3) Temperature sensors CC-E/TC Thermocouples (IEC 584-1 and 2) Standard signals PT100 TC.K, TC.J 0...20 mA / 0...5 V / -50...+500 °C TC.K: 0...1000 °C, 4...20 mA 0...10 V / TC.J: 0...600 °C -10...+10 V +55 mA ± 11 V < 0.01 %/ < 0.5 % / 100  ± 5 % (universal devices) ± 5 % (universal devices) 50  1 M > 35 dB 100 dB D-F, A-C Current Voltage 0-20 mA, 4-20 mA 0-5 V, 0-10 V  500  1.0 K ± 0.5 % of full-scale < 0.5 % 200 µs 10 ms 2 kHz 80 Hz 2 Hz (up to -3...

Open the catalog to page 11
Analog signal converters - 12

Analog signal converters - CC-E range Technical data Type Input circuits - Analog inputs Input current I IN Min. input current Max. input current Input voltage U IN Input voltage drop U i Max. input voltage Output circuits Output current I OUT Output load R L Output voltage U OUT Residual ripple Response time (0-100 %) Accuracy Load influence (0-500 ) General data Width of the enclosure Weight Mounting position Degree of protection Ambient temperature range Temperature coefficient Mounting Electrical connection Wire size Stripping length Tightening torque Standards Product standard Low...

Open the catalog to page 12
Analog signal converters - 13

Analog signal converters - CC-E range Technical data Type Input circuits - Analog inputs Rated input range Measuring frequency Overload capacity of inputs Gain adjustment range Offset adjustment range Input impedance / resistance Output circuits - Analog outputs input range 1 10 x I (50 A) for max. 1 s Nom input range 2 10 x I (200 A) for max. 1 s Nom ±5 % (universal devices) ±5 % (universal devices) 5A : 65 m 20 A : 2.5 m D-F Current A-C Voltage Output signal Supply circuits Supply voltage ± 2 % of full-scale ±5 % (universal device) ±5 % (universal device) < 0.5 % 0.5 s DC or 50/60 Hz...

Open the catalog to page 13
Analog signal converters - 14

Analog signal converters - CC-U range Overview CC-U range –– 8 different standard signal outputs on one device –– Input and output side universally configurable –– Also available with 2 threshold relay outputs –– Adjustment and operating elements on the front side –– Safe operation by electrical 3-way isolation –– Plug-in connecting terminals, unambiguously and clearly ­marked Conversion, measurement and separation of –– Standard signals –– Signals of RTD sensors (PT10, PT100, PT1000) –– Thermocouple signals –– TRMS values of currents and voltages Characteristics – – The required input and...

Open the catalog to page 14
Analog signal converters - 15

Analog signal converters - CC-U range Overview CC-U/STD universal signal converter with 3-way electrical isolation –– ore than 120 configurations possible M –– onfigurable output signal response on input voltage signal C interruption (low fail safe / high fail safe) –– djustment and operating elements on the front A –– hort-circuit proof signal outputs S –– lug-in connecting terminals for inputs, outputs and supply P –– ery fast signal transmission enables use in control sysV tems CC-U/STDR universal signal converter for standard signals, with 2 threshold relay outputs and with 3-way...

Open the catalog to page 15

All ABB Smart Power catalogs and technical brochures

  1. Bus couplers

    3 Pages

  2. SlimLine XR

    52 Pages

  3. SACE Emax 2

    277 Pages

  4. TruOne

    68 Pages

  5. OFAM/ OFAA

    2 Pages

  6. SACE Tmax XT

    8 Pages

  7. ABB Division

    17 Pages

  8. V400

    2 Pages

  9. V16

    2 Pages

  10. P42E

    2 Pages

  11. Nightstar

    2 Pages

  12. EasyLine XLP

    31 Pages