Group: ABB
Catalog excerpts
Cost-effective measuring system Indication on site without external power supply Measurement of even small gas and liquid flows Independent of electrical conductivity Versions approved for use in hazardous areas High reproducibility ABB Instrumentation Proven measuremt for gases, liquids and steam Variable Area Flowmeters VA Master
Open the catalog to page 1VA Master line – versatile and well-proven The use of variable area flowmeters in industrial process measurement has been established for more than 70 years. Their measuring principle is both technically mature and cost-effective. They feature an amazing design variety and high reproducibility and do not require an external power supply for measured value indication on site. As a result, they are the appropriate solution for almost all applications involving the measurement of liquids, gases or steam. Various metal or glass tube models are available. Measuring Principle Three forces are...
Open the catalog to page 2Metal tube – Glass tube The ABB product range includes both metal tube and glass tube instrument lines and is used in the widest variety of applications: The purgemeters of both product lines are available with a differential pressure regulator that balances pressure variations in the system and provides a constant flow rate. ABB flowmeters can easily handle very small measuring ranges, e.g. in labs, and high flow rates for rugged industrial applications. Application examples in various industries Analytical Mixing, dosing, monitoring Automotive Test benches, lubricants, cooling water...
Open the catalog to page 3Overview metal tube devices The well-proven, robust metal tube flowmeters are suitable for a wide range of applications. They have proved their worth for aggressive and opaque fluids or extremely demanding operating conditions. They are indispensable for applications requiring high pressure and temperature resistance. Flow rate 0.1…120.000 l/h (Qv) water or 0.008…3,600 m3/h (Qn) air (14.7 psia and 32 °F) Stainless steel primary Alarm contacts 4…20 mA output signal Metal tube Measuring point Accuracy class 6 Dosing Low-cost device Low installation costs Differential pressure regulation...
Open the catalog to page 4These universal flowmeters are used in many industries for measuring and dosing liquids and gases. Due to the combination of various process-wetted materials they are suitable for even aggressive fluids. Overview glass tube devices Flow rate 0.002…17.600 l/h (Qv) water or 4 cm3/min…520 m3/h (Qn) air at 1.013 bar (a) and 0 °C (14.7 psia and 32 °F) Visual fluid monitoring Alarm contacts Glass tube Measuring point Accuracy class 1.6...6 Dosing Low-cost device Low installation costs Differential pressure regulation FAG6100 Accuracy class 1.6 Variety of process connections Measurement of more...
Open the catalog to page 5VA Master FAM540 The FAM540 series is based on a modular system offering flowmeters with a simple indicator or including an advanced electronic transmitter. The combination of the various models with the different indicators provides suitable flow solutions for each application. The comfortable operation via the graphical display allows an simple adjustment to changing operating conditions. Various application ranges Device designs ranging from simple to demanding applications Standard fluid temperature up to 400 °C (750 °F) Insulation up to flange diameter due to the unique decouple-proof...
Open the catalog to page 6Advantages of the Microprocessor Transmitter Convenient and intuitive operation with clear text configuration Medium properties can be changed at any time Configuration possible without opening the housing Automatic self-monitoring with error diagnosis Flow rate values are readable even in case of power failure Technical Data Power supply: 10...46 V DC (Ex 10…28 V DC) Current output: 4…20 mA, load < 750 ohm Digital output (Namur): Function selectable in the software - Alarm: Min, Max or Min-Max - Pulse output: fmax 100 Hz, 1…256 ms pulse width Display: High-contrast LCD with clear text...
Open the catalog to page 7FAM3200 Economic Use When designing these devices, special attention was paid to flexibility and the capability to adapt to the prevalent operating conditions. The installation length of only 90 mm with horizontal connections allows for easy installation in confined spaces. The meter's sturdy all-metal design is easy to service and requires little maintenance. Cost-saving installation due to threaded connections; no expensive counter-flanges required Space-saving installation Robust design This small variable area flowmeter with its all-metal design ensures that even under extreme...
Open the catalog to page 8Beneficial Versions Limit contacts are important components in monitoring the flow rate of processes. A maximum of 2 contacts for minimum and maximum alarms is possible. The electrical transmitter provides an analog 4…20 mA output signal in 2-wire technology which is proportional to the flow rate. Technical Data Flameproof design TÜV 03 ATEX 2151 II 1/2 G c T6 or II 1/2 G EEx c ia IIC T6 or II 2 D T115 °C Alarm contacts - Min./max. “NAMUR contact” proximity switch - Perm. ambient temperature -20…45 °C (-4...113 °F) Transmitter - Rotational angle sensor - 4…20 mA output signal - Perm....
Open the catalog to page 9FAG1190 This variable area flowmeter is a cost-effective and universal measuring instrument. The process-wetted components are available in various materials. Due to the wide range of different float types and measuring tubes, these devices can be adapted easily to the prevalent operating conditions. Device features Cost-effective measuring system Customer-specific flow units Visual fluid monitoring Thread and flange connection Optional alarm contacts for 1/2“ and above Measuring tube and float can be replaced independently of each other Easy tube disassembly through O-ring seals Technical...
Open the catalog to page 10Device features With the built-in needle valve the flow rate can be both adjusted and regulated. An attached differential pressure regulator in combination with the needle valve maintains the flow rate independently of any pressure variations. The optional limit contacts are essential components for monitoring the preset flow rate values. This is how processes can be controlled in an optimal way with a single device. Space-saving installation Visual fluid monitoring Easy to service snap-in design Alarm sensors for monitoring a preset measuring range (optional) Differential pressure...
Open the catalog to page 11All ABB Measurement & Analytics catalogs and technical brochures
-
Sensyflow FMT700-P Compact
4 Pages
-
CoriolisMaster FCB100, FCH100
60 Pages
-
ProKiln GAC400
24 Pages
-
AV1 and AV2
24 Pages
-
OriMaster FPD500
24 Pages
-
AquaProbe FEA200
16 Pages
-
FTPA2000-HP260
4 Pages
-
266HSH and 266NSH
40 Pages
-
261GC, 261GG, 261GN and 261AC
44 Pages
-
LM200 Laser level transmitter
24 Pages
-
LLT100 Laser level transmitter
26 Pages
-
CoriolisMaster FCB400, FCH400
104 Pages
-
PME120-AI / PME120-AN (Contrac)
28 Pages
-
Millmate roll force systems
20 Pages
-
FTSW100 Process software
4 Pages
-
Totalflow host software
8 Pages
-
SCK
20 Pages
-
SCADAvantage™ EFM Tool
4 Pages
-
INDI-BOY DSP
8 Pages
-
CRANE-BOY / CRANE-BOYP
8 Pages
-
9QGPS5100L Tension load cell
12 Pages
-
9QGPS4500
8 Pages
-
9QGPS3100P
12 Pages
-
9QGPS2960
12 Pages
-
9QGPS2625
8 Pages
-
Ultrasonic level LST400
12 Pages
-
MB3600-HP10
5 Pages
-
MB3600-CH10
8 Pages
-
ACF5000
16 Pages
-
Diode laser analyser LS4000
4 Pages
-
Magnos28
10 Pages
-
Dynamic QR Code
4 Pages
-
EL3060
8 Pages
-
Pressductor Radial load cells
20 Pages
-
HP30
4 Pages
-
Aztec ATS430
12 Pages
-
LMS200
12 Pages
-
PGC5000
8 Pages
-
LGR-ICOS 927S
4 Pages
-
Recording and Control
20 Pages
-
2600T Pressure Transmitters
12 Pages
-
TZIDC and TZIDC-200
8 Pages
-
ProcessMaster FEP610
8 Pages
-
ALSCAN Brochure
6 Pages
-
MR Series
2 Pages
-
Emission Monitoring
8 Pages
-
Turbidity Systems 4670 Series
16 Pages
-
Sodium Monitor Model 8036
8 Pages
-
Aztec 600 Iron Analyzer
12 Pages
-
First for Liquid Analysis
16 Pages
-
ABB product catalog
32 Pages
-
process photometer
6 Pages
-
Sodium Monitor Model 8036
8 Pages