TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation
12Pages

{{requestButtons}}

Catalog excerpts

TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 1

Data Sheet DS/TTR200-EN Rail mounted Temperature Transmitter TTR200 HART, Pt100 (RTD), thermocouples, Electrical isolation Input - Resistance thermometer - Thermocouples - Resistance-type transmitters - Voltages, mV voltages Output - 4 ... 20 mA, HART Measurement deviation - 0.1 K Sensor error adjustment Continuous sensor monitoring and selfmonitoring - Two function LEDs - Supply voltage monitoring - Wire break and corrosion monitoring in accordance with NE 89 Device safety in accordance with NE 53 SIL2 acc. to IEC 61508 Approvals for explosion protection - ATEX, IECEx, Zone 0 - FM / CSA Configuration - DTM - EDD Contents

Open the catalog to page 1
TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 3

Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 3 1 Specifications Change from one to two columns 1.1 Input 1.1.1 Resistance thermometers/Resistors Resistance thermometer Pt100 in accordance with IEC 60751, JIS C1604-81, MIL-T- 24388, Ni in accordance with DIN 43760, Cu Resistance measurement 0 … 500 Ù 0 … 5000 Ù Sensor connection type Two-, three-, four-wire circuit Connecting cable Maximum sensor line resistance (RW) for each line 50 Ù according to NE 89 (January 2009) Three-wire circuit: symmetrical sensor line resistances...

Open the catalog to page 3
TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 4

Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 4 2 General information Change from one to two columns CE Marking The TTR200 meets all requirements for the CE mark in accordance with IEC 61326 (2006) Electrical isolation 3.5 kV DC (approx. 2.5 kV AC) 60 s, input to output MTBF time 28 years at 60 °C ambient temperature Input filter 50 / 60 Hz Switch-on delay < 10 s (Ia 3.6 mA during starting cycle) Warm-up time 5 minutes Ramp-up time t90 400 … 1000 ms Rate updated 10/s, independent of sensor type and sensor circuit Output...

Open the catalog to page 4
TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 5

Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 5 Change from one to two columns 2.6 Measuring accuracy Includes linearity deviation, reproducibility/hysteresis at 23 °C (73.4 °F) ± 5 K and 20 V supply voltage Information on measuring accuracy corresponds to 3 ó (Gaussian distribution) Input element Standard Sensor Measuring range limits Minimum span Digital measuring accuracy (24-bit A/D converter) D/A measuring accuracy 1) (16-bit DA) Resistance thermometer/resistor IEC 60 751 Pt10 Pt50 Pt100 Pt200 Pt500 Pt1000 (a=0,003850)...

Open the catalog to page 5
TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 6

Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 6 2.7 Operating influences The percentages refer to the configured measuring span. Supply voltage influence/load influence: within the specified limits for the voltage/load, the total influence is less than 0.001 % per volt Common-mode interference: no influence up to 100 Veff (50 Hz) or 50 V DC Ambient temperature influence: based on 23 °C (73.4 °F) for ambient temperature range -40 ... 85 °C (-40 ... 185 °F) Sensor Influence of ambient temperature per 1 °C (1.8 °F) deviation to...

Open the catalog to page 6
TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 7

Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 7 Kommunikation 3 Communication Change from one to two columns 3.1 Configuration parameters Measurement type Sensor type, connection type Error signaling Measurement range General information, e.g., TAG number Damping Signal simulation of output For additional information, see Section 8, "Order form configuration" Write protection Software write protection Diagnostic information in accordance with NE 107 Sensor error (wire break or short circuit) Device error Over/under alarm...

Open the catalog to page 7
TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 8

Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 8 4 Electrical connections Fehler! Verweisquelle konnte nicht gefunden werden. A00203 12 ... 30 / 42 V DC + 11 - 4 ... 20 mA TTR200 + 11 PWR ERR OFF ON 1 2 - 1 2 3 4 5 6 A 4 2 2 2 1 1 1 1 1 1 4 3 3 3 3 3 3 2 1 2 3 4 5 6 + - 7 2 3 + - 8 9 2 3 Fig. 3 1 Potentiometer, four-wire circuit 2 Potentiometer, three-wire circuit 3 Potentiometer, two-wire circuit 4 RTD, four-wire circuit 5 RTD, three-wire circuit 6 RTD, two-wire circuit 7 Voltage measurement 8 Thermocouple 9 Terminal 11:...

Open the catalog to page 8
TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 9

Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 9 Bestellangaben 6 Ordering information Main order number Add. order no. Version number 1 - 6 7 8 9 10 11 XX TTR200 rail-mounted temperature transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation TTR200 X X X X X XX Explosion protection Without explosion protection Y 0 ATEX intrinsic safety type of protection: Zone 0: II 1 G Ex ia IIC T6, zone 1 (0): II 2 (1) G Ex [ia] ib IIC T6, Zone 1 (20): II 2 G (1D) Ex [iaD] ib IIC T6 E 1 ATEX non-sparking type of protection:...

Open the catalog to page 9
TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 10

Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 10 7 Ex relevant specifications Change from one to two columns The TTR200 complies with the requirements of ATEX Directive 94/9/EC. 7.1 TTR200-E1, Intrinsic Safety ATEX Explosion protection Approved for use in Zone 0 and 1 Designation II 1G Ex ia IIC T6 (Zone 0) II 2(1)G Ex [ia] ib IIC T6 (Zone 1 [0]) II 2G(1D) Ex [iaD] ib IIC T6 (Zone 1 [20]) EC type-examination test certificate PTB 05 ATEX 2017 X 7.2 TTR200-H1, Intrinsic Safety IECEx Designation Ex ia IIC T6 Ex [ia] ib IIC T6 Ex...

Open the catalog to page 10
TTR200 - Rail mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation - 12

ABB has Sales & Customer Support expertise in over 100 countries worldwide. www.abb.com/temperature The Company’s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (04.2010) © ABB 2010 3KXT241001R1001 DS/TTR200-EN Rev. B ABB Limited Salterbeck Trading Estate Workington, Cumbria CA14 5DS UK Tel: +44 (0)1946 830 611 Fax: +44 (0)1946 832 661 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Automation Products GmbH...

Open the catalog to page 12

All ABB Measurement & Analytics catalogs and technical brochures

  1. ProKiln GAC400

    24 Pages

  2. AV1 and AV2

    24 Pages

  3. SCK

    20 Pages

  4. INDI-BOY DSP

    8 Pages

  5. 9QGPS4500

    8 Pages

  6. 9QGPS3100P

    12 Pages

  7. 9QGPS2960

    12 Pages

  8. 9QGPS2625

    8 Pages

  9. MB3600-HP10

    5 Pages

  10. MB3600-CH10

    8 Pages

  11. ACF5000

    16 Pages

  12. Magnos28

    10 Pages

  13. EL3060

    8 Pages

  14. HP30

    4 Pages

  15. Aztec ATS430

    12 Pages

  16. LMS200

    12 Pages

  17. PGC5000

    8 Pages

  18. MR Series

    2 Pages