The specialists for hazardous areas Advance Optima and EasyLine
Open the catalog to page 1— ABB Analytical possesses decades of experience in the area of explo sion protection. This competence is unified with a unique portfolio based on the Advance Optima and EasyLine series. Simplicity is key for safe operation in hazardous areas and ABB Ana lytical offers the right analyzer portfolio from extractive to in-situ analyzers. Independent if ATEX, IECEx, CSA, or further local approvals are needed for installation in plants with potentially explosive gas atmospheres in Zone 1 and Zone 2, ABB is your one stop shop
Open the catalog to page 2— Advance Optima and EasyLine Two analyzer series fits all With Advance Optima (AO2000 Series) and EasyLine (EL3000 and EL3060 Series) ABB offers a broad range of continuous gas analyzers for the measurement in hazardous areas. From simple measuring task up to complex and flexible system solution, these are all possible with the EL3000, AO2000 and EL3060. Furthermore, a wide variety of different measuring technologies are available with all needed local certificates ex-works. Zone 2 or Class 1, Division 2
Open the catalog to page 3— Zone 2 non-flammable gases / Class I, Div. 2 AO2000 Whole functionality and flexibility of the Advance Optima series is also available for Zone 2 installation, for measurement of non-flammable gases, or for Class I, Division 2 installation. There is no need for additional case purging, all the assemblies have been tested to ensure that they are non-incendive. Protection concept An AO2000 device for operation in Zone 2, for measurement of non-flammable gases, or Class I, Division 2, is based on non-incentive Ex nC electronic components encapsulated in a tough IP54 housing. Both versions do not...
Open the catalog to page 4EL3040 “So smart, they’re simple” of the EasyLine series, is for sure also valid for the measurement of non-flammable gases in hazardous area Zone 2. The compact EL3040 housing can combine up to two analyzer modules in one housing and can be operated with the smart operation concept of EasyLine. Protection concept An EL3040 device for operation in Zone 2, for measurement of non-flammable gases, is based on non-sparking Ex ec electronic components encapsulated in a tough IP65 housing. An additional purge system is not required. Available analyzer modules are Uras26, Magnos28, Caldos27 and O2-Sensor....
Open the catalog to page 5— Zone 2 flammable gases AO2000 “Safety Concept” The “Safety Concept” of the Advance Optima series ensures the impermeability of its measuring system, minimizes the purging volume and realizes a simple setup for the measurement of flammable gases in hazardous Zone 2. Individual system solutions with an external purge controller or a separate purgeable housing are redundant. Protection concept An AO2000 Safety Concept device is based on non-incentive Ex nA electronic components and a simplified pressurized encapsulation Ex pyb around the analyzer module Uras26, Caldos25/27 and Magnos28. — Safety...
Open the catalog to page 6— Zone 1 / Class I, Div. 2 AO2000-LS25 If harsh process conditions or fast process control necessitates an In-Situ measurement, we can offer the right solution, even in hazardous area. AO2000-LS25 is available in special versions for installation in Zone 1 or Zone 2 for gas environment as well as in Zone 21 or Zone 22 for dust environment. A Class I, Division 2 version is also available. Protection concept An AO2000-LS25 device is always based on limitation of optical radiation Ex op is for the laser beam. The whole electronic components are non-incentive Ex nC and for Zone 1 in addition a pressurized...
Open the catalog to page 7— Zone 1 AO2040-Fidas24 Ex Would you light a flame in hazardous area? We do! AO2040-Fidas24 Ex is a compact product solution designed around the standard AO2040 field housing to measure total hydrocarbons. The analyzer is certified for used in hazardous areas with gas (Zone 1, Zone 2) as well as in hazardous areas with dust (Zone 21 or Zone 22). Zone 2 Zone 1 Zone 0 Explosion proof Protection concept An AO2040-Fidas24 Ex device is based on a pressurized encapsulation Ex pxb around the Fidas24 analyzer module and an intrinsically safe Exib display and control unit for operation of the analyzer....
Open the catalog to page 8EL3060 EL3060, the first choice for installation in hazardous area Zone 1! This analyzer series uses the analyzer modules with the same measuring performance as in the Advance Optima series and combined it with the simplicity of the EasyLine series. That makes the EL3060 a powerful but compact and easy to handle solution. Protection concept An EL3060 device is made up of the flameproof Ex db enclosed control unit with an increased safety Ex eb junction box. • integrated into the housing of the control unit – Magnos28, Caldos25 or Caldos27 • built into a separate flameproof Ex db enclosure which...
Open the catalog to page 9— The different analyzer modules …for use in hazardous area! — Uras26 Infrared photometer Thermal conductivity detector Uras26 is an NDIR photometer which can measure up to four infrared active gases simultaneously. • • • • • • • Components: CO, NO, N2O, SO2, CO2, CH4, C3H8, C2H4, … Ranges: 0 - 5 ppm up to 100 vol% Measure up to 4 components simultaneously Measure up to 2 gas streams continuously Easy to add and change measuring components in field Internal calibration cells minimize cost of ownership Gas-filled detectors for highly selective measurement Magnos28 is a paramagnetic oxygen analyzer...
Open the catalog to page 10— Product selection matrix Quick finder for the right analyzer flammable gases
Open the catalog to page 11— ABB Measurement & Analytics For your local ABB contact, visit: www.abb.com/contacts — Copyright© 2021 ABB All rights reserved For more product information, visit: www.abb.com/measureme
Open the catalog to page 124 Pages
60 Pages
24 Pages
24 Pages
24 Pages
16 Pages
4 Pages
40 Pages
44 Pages
24 Pages
26 Pages
104 Pages
28 Pages
20 Pages
4 Pages
8 Pages
20 Pages
4 Pages
8 Pages
8 Pages
12 Pages
8 Pages
12 Pages
12 Pages
8 Pages
12 Pages
5 Pages
8 Pages
16 Pages
4 Pages
10 Pages
4 Pages
8 Pages
20 Pages
4 Pages
12 Pages
12 Pages
8 Pages
4 Pages
20 Pages
12 Pages
8 Pages
8 Pages
6 Pages
2 Pages
8 Pages
16 Pages
8 Pages
12 Pages
16 Pages
32 Pages
6 Pages
8 Pages