1. Catalogs
  2. ABB Measurement & Analytics
  3. PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters

PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters

PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters
1 / 44 PagesView full catalog

PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters

Product catalog summary
Overview: The document provides comprehensive details on ABB's PxS100, PxF100, PxP100, and PxD100 pressure transmitters, highlighting their robust performance, high accuracy, and flexible configuration options for various industrial applications.
Key Specifications:
  • Accuracy: Ranges from ±0.25% to ±0.075% of the calibrated span.
  • Span Limits: 0.3 – 10000 kPa; 16 inH2O up to 1450 psi.
  • Turn Down Ratio: Up to 100:1.
  • Housing: Stainless steel, optimized for industrial environments.
  • Configuration: Local setup via touch keypad, handheld terminal, or PC interface.
  • Compliance: PED Category III, RoHS II Directive 2011/65/UE.
Model Descriptions:
  • PxS100: Suitable for liquid, gas, or steam applications in hazardous areas.
  • PxF100: Designed for sanitary, food & beverage processes with a high visibility display and touch HMI.
  • PxD100: Features S26 diaphragm seal line accessories, eliminating leakage risks.
  • PxP100: Tailored for Pulp & Paper processes with specialized connections and materials.
Physical Specifications:
  • Materials: AISI 316 L ss, Hastelloy C276, Diaflex, and others.
  • Filling Fluids: Options include silicone oil, inert fill, mineral oil, and vegetal oil.
  • Mounting: Universal brackets for different orientations.
  • Display: Rotatable in 5° increments, with optional touch glass.
Functional Specifications:
  • Range and Span Limits: Detailed for different sensor codes.
  • Damping: Configurable time constant between 0 and 60 seconds.
  • Insulation Resistance: >100 MΩ at 500 V DC.
Operative Limits:
  • Pressure Limits: Overpressure limits specified for different sensor codes and models.
  • Temperature Limits: Operating, process, and storage temperature ranges detailed for each model.
Additional Information: Detailed tables on pressure limits, temperature limits, and fill fluid characteristics emphasize the importance of adhering to specified limits to ensure device integrity and performance.
Specifications: The document outlines specifications for various oils and pressure transmitters, including environmental limits, performance, and certifications.
Procedures: Describes selection criteria for seal systems and procedures for configuring transmitters with HART communication and 4-20 mA output.
Standards and Norms: Ensures compliance with standards like EMC Directive 2014/30/EU, Pressure Equipment Directive 2014/68/EU, and safety approvals like ATEX, IECEx, and CSA.
Recommendations: For optimum accuracy, select the sensor code with the lowest turndown value and consider ambient temperature effects on performance.
Key Data from Tables: Provides detailed information on oil properties and seal model compatibility with transmitter sensors.
Critical Information: Highlights accuracy ratings, temperature effects on performance, and the importance of selecting appropriate filling fluids.
Specifications and Configurations: Outlines configurable parameters such as linear output, damping time, and transmitter failure mode.
Tag and Calibration: Tags and calibration spans must be ordered with option code SC, with specific options for short and long tags.
Mounting Dimensions: Provides detailed mounting dimensions for various models and connection types.
Electrical Connections: HART communication requires a minimum loop resistance of 250 ohms.
Ordering Information: Comprehensive guide for ordering pressure transmitters, detailing base models, sensor ranges, diaphragm materials, fill fluids, and process connection materials.
Notes and Remarks: Clarifies compatibility and restrictions for certain options, emphasizing the importance of selecting suitable wetted parts and filling fluids.
Additional Options: Includes LCD displays, extended performance accuracy, hazardous area certifications, and various accessories.
Compliance and Certifications: Lists inspection and compliance certificates available for the transmitters.
Labels and Manuals: Options for label and display visualization in different units and languages are provided.
Important Notes: Compatibility with process media is the customer's responsibility unless otherwise notified before manufacturing.
Legal and Contact Information: ABB reserves the right to make changes to the document and disclaims responsibility for errors. Contact information for ABB is provided for further inquiries.
See more

Catalog excerpts

PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-1

ABB MEASUREMENT & ANALY TICS | DATA SHEET PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters

 Open the catalog to page 1
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-2

— Measurement made easy Engineered solutions for all applications Standard overload resistance Base accuracy • From ± 0.25 % up to ± 0.075 % of calibrated span Span limits • 0,3 – 10000 kPa; 16 inH2O up to 1450 psi • 0,3 – 10000 kPa abs; 30 mmHg up to 1450 psia Proven sensor technology together with state-of-the-art digital technology • Valuable turn down ratio of up to 100:1 Stainless steel housing • Optimized for use in industrial process environments • Extremely robust New touch keypad technology • allows quick and easy local configuration without opening the cover, even in hazardous classified...

 Open the catalog to page 2
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-3

— General Description PxS100 Model PxS100 is the compact, reliable, essential pressure transmitter suitable for liquid, gas or steam applications. It is a straightforward and robust device designed for rapid delivery and easy installation and use. Thanks to its rugged design offering high resistance in even the most demanding environments, it is a competitive solution for most applications, including ones in hazardous areas. PxD100 Model PxD100 is the pressure transmitter from the Pxx100 series featuring the S26 diaphragm seal line accessories. While having a compact, sturdy stainless-steel housing...

 Open the catalog to page 3
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-4

— Specification - Physical(1) Materials Process isolating diaphragms (2) AISI 316 L ss, Hastelloy C276, Diaflex (antiabrasion), H-Shield (against hydrogen permeation) Process connection (2) AISI 316 L ss Hastelloy C276 (Available on request) Filling fluids (3) Silicone oil, inert fill (fluorocarbon), Mineral oil (FDA approved), Vegetal oil (FDA approved) Mounting bracket AISI 304 ss Sensor housing, electronics housing and cover AISI 316 L ss Filter for atmospheric ventilation • Filter material: polyamide (PA) • Filter housing: plastic (general purpose version), stainless steel (Ex certified versions)...

 Open the catalog to page 4
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-5

— Functional – specification Range and span limits Sensor code Upper range limit (URL) Lower range limit (LRL) Minimum measuring span Model PGx100 Model PAx100 Gauge Absolute pressure pressure IMPORTANT (NOTE) The lower range limits (LRL) for models PAx100 are 0 absolute for all measuring ranges. Span limits Maximum span = upper range limit (URL) To optimize performance characteristics, it is recommended that you select the transmitter sensor code providing the lowest turn down ratio. TURNDOWN = Upper range limit / set span Zero suppression and elevation Zero and span can be adjusted to any value...

 Open the catalog to page 5
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-6

— Specification – Operative limits Pressure limits Overpressure limits Without damage to the transmitter No damage will occur during transmitter operation, if they are used within the specifications and subject to the following limits: Model PxP100 Seal type Sensors The below table shows the maximum pressure limits of the connection when coupled with customer process interface. It also shows the compatibility of the sensor ranges. Pressure limit Universal G1" hygienic - AISI Universal G1" hygienic - HC Universal G1" hygienic Diaflex on AISI Seal model (Standard) Sensors L to R Diary 11851 DN50...

 Open the catalog to page 6
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-7

Temperature limits °C (°F) Ambient Seal model (Standard) Seal diaphragm size (thickness) / flange type PN 16 "Max. pressure Carbon steel flange @ 120 °C" "Max. pressure AISI 316 ss flange @ 20 °C" Ambient temperature limits Operating temperature range Process temperature limits Process temperature range Seal model (Standard) Seal diaphragm size (thickness) / flange type "Max. pressure AISI 316 L ss flange @ 20 °C" 1.6 Mpa, 16 bar, 230 psi Please refer to process temperature limits driven by S26 remote seals Process temperature limits Process temperature range EPDM gasket for universal connection...

 Open the catalog to page 7
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-8

— ...Specification – Operative limits Refer to the following FILL FLUID CHARACTERISTICS table detailing characteristics of fill fluids when used in transmitters. Operational limits may vary depending on the materials, gasket and configuration selected. Models Fill fluid (application) Process temperature and pressure limits Pmin mbar abs (mmHg) Inert oil Galden G5 (oxygen service) Silicone polymer Syltherm XLT (cryogenic service) Silicone oil for high temperature (for REMOTE SEAL) Silicone oil for high temperature (for DIRECT MOUNT SEAL) Vegetable oil Neobee M-20 (food - sanitary) FDA approved...

 Open the catalog to page 8
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-9

Model PGD100, PAD100 Seal system selection criteria The following table shows the types of seals available as direct mount and remote. According to the combination SEAL/TRANSMITTER SENSOR the table details the compatibility for one direct mount seal construction and the MAXIMUM CAPILLARY LENGTH when a seal is selected as remote. The mnemonics will be used as shortest cross references in the S26 data sheet. Seal model Seal type "Seal diaphragm size (thickness) [flange type]" Direct mount seal Remote seal Flanged flush diaphragm (ASME and EN standards) 1.5 in /DN 40 Wafer (ASME and EN standards)...

 Open the catalog to page 9
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-10

— ...Specification – Operative limits Environmental limits Electromagnetic compatibility (EMC) The devices comply with the requirements and tests for EMC Directive 2014/30/EU to standards EN 61326-1 Table2 (industrial electromagnetic environment) concerning both emitted interference (CISPR11) and interference immunity. • Burst test: up to 2 kV at 5 kHz and 100 kHz • Surge test: up to 1 kV line-line and 2 kV line-ground Radiated emission: Group 1 - class B according to CISPR11 • FCC 47 CFR part 18.305 • ICES 005 - Issue 4 Conducted emission: group 1 - class A according to CISPR11 and to CISPR32...

 Open the catalog to page 10
PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters-11

— Specification - Performance Reference conditions according to IEC 62828-1 • Ambient temperature constant in the range 15 – 25 °C (59 – 77 °F) • Relative humidity constant in the range 50 – 70 % • Ambient pressure constant in the range 860 – 1060 mbar • Measuring span based on zero position • Transmitter with AISI 316 L or Hastelloy C276 process isolating diaphragm • Filling fluid: Silicone oil • Supply voltage: 24 V DC ± 1 % • Load with HART: 250 Ω • Transmitter not grounded • Characteristic setting: linear, 4 – 20 mA. Unless otherwise specified, errors are quoted as % of calibrated span. Some...

 Open the catalog to page 11

All ABB Measurement & Analytics catalogs and technical brochures

  1. ProKiln GAC400

    24  Pages

  2. AV1 and AV2

    24  Pages

  3. SCK

    20  Pages

  4. INDI-BOY DSP

    8  Pages

  5. 9QGPS4500

    8  Pages

  6. 9QGPS3100P

    12  Pages

  7. 9QGPS2960

    12  Pages

  8. 9QGPS2625

    8  Pages

  9. MB3600-HP10

    5  Pages

  10. MB3600-CH10

    8  Pages

  11. ACF5000

    16  Pages

  12. Magnos28

    10  Pages

  13. EL3060

    8  Pages

  14. HP30

    4  Pages

  15. Aztec ATS430

    12  Pages

  16. LMS200

    12  Pages

  17. PGC5000

    8  Pages

  18. LGR-ICOS 927S

    4  Pages

  19. MR Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.