ProKiln GAC400

ProKiln GAC400
1 / 24 PagesView full catalog

ProKiln GAC400

Product catalog summary
Overview
The ProKiln GAC400 is a specialized sampling system for dry gas sampling at rotary cement kiln and calciner gas exits. It is designed to handle high dust and aggressive gas environments typical in cement plants, featuring patented probe cleaning technology to ensure reliable measurements.
Key Features
  • Reliable Measurement: Equipped with dual air blasters, a probe tip filter, and a tip shield to prevent dust interference.
  • Ease of Operation: Operated via a user-friendly touch panel with industry-standard protocols.
  • Maintenance: Simplified manual cleaning with no special training required and no moving parts.
  • Availability: Offers solutions with over 95% and 100% availability using single and double probes, respectively.
System Structure
The system includes a water-cooled probe, control cabinet, heat exchanger, and cooling unit. It is compatible with both hot/wet and cold/dry analysis systems and can be integrated with ABB’s AO2000 System.
Retractor Description
The retractor uses an electrical drive for reliability and automatically retracts the probe during power failures or cooling issues. It features protective covers for cables and hoses.
Specifications
  • Retractor with a two-sided double V-beam track.
  • Electric motor with chain drive and air blasters.
  • Heated sample gas line at 180°C (356°F).
  • IP 54 protection rating.
Gas Sampling Probes
The water-cooled probe is designed for aggressive environments, featuring air blasters and a filter for effective dust separation.
Cooling System
Includes a water tank and heat exchanger panel, operating with a non-pressurized cooling circuit for easy maintenance.
Control Cabinet
Houses the control system and operator interface, featuring distributed I/O’s for easy installation and communication.
Specifications
  • Industrial controller with a 7” color touch panel.
  • Power supply: 380 to 480 V AC, 3-phase, 50/60 Hz, 20 A.
  • Cabinet material: EN 1.4301 (AISI 304), IP 54 rating.
  • Weight: Approximately 75 kg (165 lb).
  • Wall mounting capability.
Operation
Supports automatic and manual modes with menu-driven sequences for operation and diagnostics.
Communication
Compatible with plant control systems via I/O signals or serial interfaces, supporting Modbus and PROFINET protocols.
Installation Requirements
  • Max installation altitude: 2000 m (6562 ft).
  • Ambient temperature: 5 to 45 °C (41 to 113 °F), with anti-freeze options for lower temperatures.
  • Compressed air supply: 6 bar, dried to 5 °C below ambient temperature.
  • Cooling water supply: Drinking-water quality, with anti-freeze if needed.
Safety and Compliance
Complies with European directives for electrical safety, electromagnetic compatibility, and machinery.
See more

Catalog excerpts

ProKiln GAC400-1

—ME ASURE ME NT & AN AL YT ICS | D AT A SHE ET ABB ProKiln GAC400 Sampling system for dry gas sampling at rotary cement kiln gas exit and calciner gas exit

 Open the catalog to page 1
ProKiln GAC400-2

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B — Measurement made easy — Reliable measurement • Powerful cleaning with 2 air blasters • Filter at the tip of the probe • No mix of sample and dust • Limiting direct dust flow based on tip shield — Easy to operate • Monitoring and operating via user-friendly touch panel • I/O signals and industry leading protocols — Easy to maintain • Thoughtful design allows easy manual cleaning • No special training required • No moving parts — Availability • Single probe solution ensures more than 95 % • Double probe solution is helpi...

 Open the catalog to page 2
ProKiln GAC400-3

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B 2 Oven flap (option) 3 Control cabinet Figure 1: System overview Application The ProKiln sampling system is especially designed for analysis in hot cement flue gases with a high content of dust and aggressive gas components. The system is made by cement specialists for use in the rough environment of a cement plant. It takes advantage of industry proven and well-known air blasters in a patented probe cleaning design. The powerful probe tip filter/nozzle configuration is designed to handle the troublesome cement process...

 Open the catalog to page 3
ProKiln GAC400-4

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B 1 Probe retractor slider with two air blasters 2 Flexible flange 3 Gas sampling probe type ProKiln 4 Automatically or manually driven oven flap 5 Heated connection box for sample gas line connection 7 Electric motor for General and UPS power supply drive (optional with pneumatic drive) 8 Mounting brackets (optional, available for floor or sealing installs) 9 Emergency stop button 0 Terminal and pneumatic connection boxes 6 Cable drag chain Figure 2: Probe retractor Description The retractor comes with an electrical drive...

 Open the catalog to page 4
ProKiln GAC400-5

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B Specifications Two side double V-beam track retractor construction • Frequency and encoder controlled electric motor with chain drive • Probe slider with double air blasters • Automatically or manually driven oven flap Cable drag chain • Cooling water tubes • Electric cables • Air blaster tubes • Heated sample gas line 180 °C (356 °F) Pneumatic box • Probe tip filter blow back • Air blaster operation probe tip nozzle • Air blaster operation probe tip periphery nozzle • Pneumatic cylinder for oven flap Terminal box • Distributed...

 Open the catalog to page 5
ProKiln GAC400-6

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B 4 Water temperature sensors 3 Water connection flange Figure 3: Gas sampling probe Description The water-cooled ProKiln sampling probe is designed to be used in cement kilns and calciners with aggressive processes. The operational focus of the ProKiln probe is to provide a steady trustworthy kiln inlet or calciner gas analysis measurement able to create confidence in the control room and easy safe and manageable handling for the maintenance crew. Two air blasters are providing a new unprecedented powerful probe tip cleaning...

 Open the catalog to page 6
ProKiln GAC400-7

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B Specifications Probe sample parts • Weather cover • Cooling jacket with air blaster nozzles and sample pipe • Filter section sintered steel 1µ (easily replaceable) • Water connection flange • 5 m Heated hose 180 °C (356 °F) in the retraction unit • Pt100 sensors for water temperature in/out • Heating element 180 °C (356 °F) for gas sample pipe (easily replaceable) Material • Cooling tube: Stainless steel EN 1.4835 (253MA) • Inner gas pipe: Stainless steel EN 1.4436 (AISI 316) Probe length • Probe length L = 1.5 m and 2...

 Open the catalog to page 7
ProKiln GAC400-8

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B — Cooling system 1 Heat exchanger with fix speed motor and emergency stop 5 Water tank panel 2 Heat exchanger panel 6 Connections forward and return probe water cooling 1″ Unions 3 Bolted connections flange between units (can be separated) 7 Connection box with local distributed I/O’s and power supply 4 Water cooling pump and flow meter 8 Water tank 300 l with temperature, level sensor and refill valve Figure 4: Cooling system Description The complete cooling system combines a water tank panel with a heat exchanger panel...

 Open the catalog to page 8
ProKiln GAC400-9

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B Specifications Cooling water circuit • Capacity water tank approx.. 300 l • non pressurized cooling system – open vessel • Controlled temperature 75 to 85 °C (167 to 185 °F) • Circulation 6 to 7 m3/h • Drinking water quality, anti-freeze agent necessary at ambient temperature < 0 °C (< 32 °F) or/and optional heater in water tank. Cooler block material Copper/brass for corrosion-proof operation Color Light grey (RAL Cla

 Open the catalog to page 9
ProKiln GAC400-10

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B — Control cabinet 1 Stainless steel IP54 cabinet 4 Signal tower with optical and acoustic signaling 2 HMI (behind protective front window) 3 Connection terminals and wire flange Figure 5: Control cabinet The control cabinet comprises the control system, including the display and operator control unit for monitoring and operating the gas sampling system. Electrical power supply for the entire ProKiln gas sampling system is feed-in and distributed through the control cabinet. The probe movement and cleaning are controlled...

 Open the catalog to page 10
ProKiln GAC400-11

PROKILN GAC400 SAMPLING SYSTEM FOR DRY GAS SAMPLING | DS/GAC400-EN REV. B Specifications Modules • Industrial controller with distributed I/O’s • 7” Color touch panel • Signal tower with optical and acoustic signaling • Emergency stop • Main switches for general and UPS power supply • Power distribution terminals and automatic fuses • Frequency controller for retractor unit operation Power supply 380 to 480 V AC 3~, N, PE; 50/60 Hz; 20 A Communication • Potential free I/O’s for status and alarms (Default) • Control Network Options: On request Material Cabinet material: EN 1.4301 (AISI 304) Color...

 Open the catalog to page 11

All ABB Measurement & Analytics catalogs and technical brochures

  1. AV1 and AV2

    24  Pages

  2. SCK

    20  Pages

  3. INDI-BOY DSP

    8  Pages

  4. 9QGPS4500

    8  Pages

  5. 9QGPS3100P

    12  Pages

  6. 9QGPS2960

    12  Pages

  7. 9QGPS2625

    8  Pages

  8. MB3600-HP10

    5  Pages

  9. MB3600-CH10

    8  Pages

  10. ACF5000

    16  Pages

  11. Magnos28

    10  Pages

  12. EL3060

    8  Pages

  13. HP30

    4  Pages

  14. Aztec ATS430

    12  Pages

  15. LMS200

    12  Pages

  16. PGC5000

    8  Pages

  17. LGR-ICOS 927S

    4  Pages

  18. MR Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.