Group: ABB
Catalog excerpts
ABB Instrumentation CoriolisMasterCoriolis Mass Flow Measurement Made in ABB >
Open the catalog to page 1Unique design Concentration measurement ֢ȒThe CoriolisMaster stands out for its unique S-design.It can be easily installed in any position and orientation where self draining is required. −Due to its sturdy design, strong signal level and optimized electronics the CoriolisMaster is insensitive to external vibrations and gas content in the fluid. −It is suitable to fluid temperatures up to 200 C / 392 аF. Due to its integral DensiMass software the CoriolisMaster allows for direct Brix measurements, net oil calculations or temperature-standardized concentration calculations. The software...
Open the catalog to page 2Transmitter ME2 −Universal transmitter for all sensors and applications for ambient temperatures between -40 and 60 C / -40 to 140 аF. −Remote or integral mount design. −Continuously rotatable transmitter head in compact design. −Illuminated graphic display with easy to read clear text menu in various languages. −Universal menu operating philosophy and easy installation using the Easy Set-upђ function. −FRAM technology for rapid transmitter exchange without re-programming. Sensor MS2 −Contoured single tube design −DN 1.5 / 3 / 6 / 10 / 15 (1/16 / 1/8Ԕ / 1/4 / 1/2ԓ) −0.15 % / 0.25 % / 0.4 %...
Open the catalog to page 3Product details Examples of typical fluids −Excellent temperature classes in explosion hazardous areas. Example: T −Sodium hydroxide −Isopropanol −Methanol −Sulfur −Sulfuric acid −Nitric acid −Benzol −Crude oil −Benzine −Kerosine −Polymers > med 200 C / 392 аF at T > amb 60 C / 140 аF, even with compact design models. −Unique flexible explosion proof design concept ֓e and ԓi in one electronic package, switchable. ԢȒComprehensive explosion proof design concept including solutions for zone 0, zone 1 and zone 2. −Flameproof enclosure offers special protection for critical processes. −Double...
Open the catalog to page 4Product details Examples of typical fluids 颈Direct mass flow measurement with an accuracy of 0.1% of range. ҢȒDensity measurement with an accuracy of 0.001 kg/l. −Excellent cleanability, EHEDG certified. −CIP and SIP suitable up to 200 C / 392 аF. −Polished fluid wetted parts. −Flexible, hygienic fitting concept. (For example Tri-Clamp or DIN11864). −Measurement of both conductible and non-conductible fluids. −Alcohol −Oils −Fats −Mashes −Pastes −Concentrates −Acids −Leaches −Milk products −Gyle −Flavors −Mayonnaise −Beer −Cream −Spirits −Sugar −Chocolate −Whey −Demineralized water −Juices...
Open the catalog to page 5Product details Examples of typical fluids −Direct mass flow measurement with an accuracy of 0.1% of range. −Density measurement with an accuracy of 0.001 kg/l. −Process safety through sturdy design and thick wall tubes. −Virtually wear-free, no moving mechanical parts contained. −Heatable up to 200 C / 392 аF. −Crude oil −Diesel −Biodiesel −Ethanol −Lime milk −Ferrous oxide −Biocide −Iron salt solution −Demineralized water −Insensitive to noise for example from external vibrations or from gas and solid content in the fluid. > 6 ABB | Instrumentation Flow Measurement ֖ CoriolisMaster...
Open the catalog to page 6Product details Examples of typical fluids −Direct mass flow measurement with an accuracy of 0.1% of range. −Density measurement with an accuracy of 0.001 kg/l. −Sturdy design and thick wall tubes. −Virtually wear-free, no moving mechanical parts contained. −Slimicide −Optical brightener −Calcium carbonate −Defoamer −Synthetic thickener −Synthetic binder −Wet strength agent −Oils and fuels −Lubricants −Sodium hydroxide −Coating colors −Kaolin −Talc −Biocide −Starch −Black liquor −White liquor −Insensitive to noise from gas or solid content. > Instrumentation Flow Measurement ֖...
Open the catalog to page 7ABB Automation Products GmbH > Note: Borsigstr. 2 63755 Alzenau, GermanyPhone: +49 551 905 534Fax: +49 551 905 555 E-Mail: CCC-support.deapr@de.abb.com > We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third...
Open the catalog to page 8All ABB Measurement & Analytics catalogs and technical brochures
-
Sensyflow FMT700-P Compact
4 Pages
-
CoriolisMaster FCB100, FCH100
60 Pages
-
ProKiln GAC400
24 Pages
-
AV1 and AV2
24 Pages
-
OriMaster FPD500
24 Pages
-
AquaProbe FEA200
16 Pages
-
FTPA2000-HP260
4 Pages
-
266HSH and 266NSH
40 Pages
-
261GC, 261GG, 261GN and 261AC
44 Pages
-
LM200 Laser level transmitter
24 Pages
-
LLT100 Laser level transmitter
26 Pages
-
CoriolisMaster FCB400, FCH400
104 Pages
-
PME120-AI / PME120-AN (Contrac)
28 Pages
-
Millmate roll force systems
20 Pages
-
FTSW100 Process software
4 Pages
-
Totalflow host software
8 Pages
-
SCK
20 Pages
-
SCADAvantage™ EFM Tool
4 Pages
-
INDI-BOY DSP
8 Pages
-
CRANE-BOY / CRANE-BOYP
8 Pages
-
9QGPS5100L Tension load cell
12 Pages
-
9QGPS4500
8 Pages
-
9QGPS3100P
12 Pages
-
9QGPS2960
12 Pages
-
9QGPS2625
8 Pages
-
Ultrasonic level LST400
12 Pages
-
MB3600-HP10
5 Pages
-
MB3600-CH10
8 Pages
-
ACF5000
16 Pages
-
Diode laser analyser LS4000
4 Pages
-
Magnos28
10 Pages
-
Dynamic QR Code
4 Pages
-
EL3060
8 Pages
-
Pressductor Radial load cells
20 Pages
-
HP30
4 Pages
-
Aztec ATS430
12 Pages
-
LMS200
12 Pages
-
PGC5000
8 Pages
-
LGR-ICOS 927S
4 Pages
-
Recording and Control
20 Pages
-
2600T Pressure Transmitters
12 Pages
-
TZIDC and TZIDC-200
8 Pages
-
ProcessMaster FEP610
8 Pages
-
ALSCAN Brochure
6 Pages
-
MR Series
2 Pages
-
Emission Monitoring
8 Pages
-
Turbidity Systems 4670 Series
16 Pages
-
Sodium Monitor Model 8036
8 Pages
-
Aztec 600 Iron Analyzer
12 Pages
-
First for Liquid Analysis
16 Pages
-
ABB product catalog
32 Pages
-
process photometer
6 Pages
-
Sodium Monitor Model 8036
8 Pages