Group: ABB
Catalog excerpts
ABB MEASUREMENT & ANALY TICS | DATA SHEET LMT200 external mount magnetostrictive level transmitter High accuracy non–intrusive liquid level and interface level detectio
Open the catalog to page 1— Measurement made easy K–TEK Level products — Features • Calibrated from the factory • High accuracy: .01 % of full scale or ±1.27 mm • No re–calibration needed: set it and forget it • Easy setup with waveform display • Not affected by agitation, foam or emulsion layers • No oscilloscope required • Designed to mount externally to K–TEK KM26 or other magnetic level gauge • Superior sensor (patent #5,473,245) • Local indication with HMI display • Dual compartment housing with separate field terminal compartment • Loop powered to 15.24 m (50 ft) probe length • Total and/or interface level...
Open the catalog to page 2— Principle of operation: The LMT200 is based upon the magnetostrictive principle. 1 1 The device electronics generates a low energy current pulse at fixed intervals. 2 The electrical pulses create a magnetic field which 2 travels down a specialized wire inside the sensor tube. 3 3 The interaction of the magnetic field around the wire and the magnetic float causes a torsional stress wave to be induced in the wire. This torsion propagates along the wire at a known velocity, from the position of the magnetic float and toward both ends of the wire. 4 4 A patented sensing element placed in the...
Open the catalog to page 3LMT200 EXTERNAL MOUNT MAGNETOSTRICTIVE LEVEL TRANSMITTER | DS/LMT200-EN REV.D Electronic transmitter Repeatability ±0.005 % Of full scale or 0.315 mm (0.012 in), whichever is greater Non-linearity ±0.01 % Of full scale or 0.86 mm (0.034 in), whichever is greater Measuring accuracy ±0.01 % Of full scale or 1.27 mm (0.050 in), whichever is greater1 Supply voltage 12 to 43 V DC for 4 to 20mA HART loop powered, 9.0 to 32 V DC for Foundation™ Fieldbus Output/Communications 4 to 20 mA HART7® or FOUNDATION Fieldbus ITK6.3.0 User interface Interactive display, DTM,...
Open the catalog to page 4— Float design for ABB K–TEK products – KM26S Every KM26 MLG float is precisely engineered to customer applica ion, ensuring optimal accuracy and performance. t Precisely spaced magnets create a 360° magnetic field coverage, safeguarding level transmitter and gauge performance, even the most challenging applications. Several materials of construction available including titanium, Monel®, Hastelloy® C, stainless steel, and plastics. Tefzel®, Halar®, TEFLON® S protective coatings are also available. Process pressures to 344 bar (5000 PSI) to full vacuum. A minimum of 75 grams of buoyancy are...
Open the catalog to page 5— Electrical connections Devices with HART communication Current output/HART output Terminal Power supply, current output/HART output PWR/COMM – EXT.METER Internal earthing terminal Power supply, current output/ 7 HART output 9 2 8 3 3 Load resistance 7 4 4 Power supply/supply isolator 5 5 PLC/DCS 6 HART handheld terminal 6 7 External indicator 7 8 External earthing terminal 8 9 Terminal for external indicator 9 0 Laptop 10 For connecting the signal voltage/supply voltage, twisted cables with a conductor cross–section of 0.8 to 0.35 mm2 (18 to 22 AWG )and a maximum length of 1500 m (4921...
Open the catalog to page 6— Power supply Devices with HART communication Terminals PWR/COMM +/PWR/COMM – Supply voltage Residual ripple Power consumption Current Output/HART output Only for devices with HART communication Terminals: PWR/COMM +/PWR/COMM – In HART communication, the smallest load is RB = 250 Ω. The load is RB is calculated as a function of the available supply voltage US and the selected, signal current IB as follows: US – min operating voltage (12.0) V DC RB Load resistance US Supply voltage IB Singal current Internal ground termination point Fieldbus lines Devices with Foundation Fieldbus...
Open the catalog to page 7— ...Probe selection guide Probe selection chart - standard 85 (185) Directions: 1. determine the maximum ambient tempearture and the maximum process temperature of the installation. 2. Plot the intersection between the two temperatures on the chart. 3. Choose the appropiate probe by matching the zone number with the probe type. *Ambient temperature is the air temperature in the work area surrounding the device. It takes into account the influence of heat created by equipment surrounding the area personnel will be working. It is not the skin temperature of the chamber or insulation blanket....
Open the catalog to page 8LMT200 EXTERNAL MOUNT MAGNETOSTRICTIVE LEVEL TRANSMITTER | DS/LMT200-EN REV.D Approvals General purpose INMETRO, ATEX/IECEx flameproof, intrinsically safe, no-sparking (protection type marked by customer) NEPSI (China), intrinsically safe NEPSI (China), flameproof housing NEPSI (China), non-sparking NEPSI (China), ATEX/IECEx flameproof, intrinsically safe, non-sparking (protection type marked by customer) ATEX/IECEx intrinsic safety ATEX/IECEx flameproof housing ATEX/IECEx flameproof non-sparking (Ex nA) EAC, intrinsically safe EAC, flameproof housing EAC, non-sparking Multi-approval -...
Open the catalog to page 9LMT200 EXTERNAL MOUNT MAGNETOSTRICTIVE LEVEL TRANSMITTER | DS/LMT200-EN REV.D Mounting orientation Bottom left connected electronic housing Bottom right connected electronic housing Top left connected electronic housing Top right connected electronic housing Housing Aluminum with 2 x M20 x 1.5 Aluminum with 2 x NPT V2 in 316L stainless steel with 2 x M20 x 1.5 316L stainless steel with 2 x NPT V in Remote/aluminum/2 x M20 x 1.5* Remote/aluminum/2 x NPT V in* Remote/stainless steel/2 x M20 x 1.5* Remote/stainless steel/2 x NPT V in* Special Through the glass (TTG) push buttons, display and...
Open the catalog to page 10Sensor probe options 90 degree bend housing extension (maximum probe length 7.62 m/25 ft) Add nitrogen purged vapor seal to standard probe Sensor special Device identification plate Add stainless steel hang tag, custom markings 4 lines, 22 characters per line Other tagging special Signal cable length (for remote transmitter only) 5 m (approx. 16 ft)* Surge protector Surge/transient protector Special other Special paint or treatment on housing Nuclear use, device to be used in a nuclear facility (application must be reviewed by ABB) Mounted accessories Mounted to chamber with vibration...
Open the catalog to page 11All ABB Measurement & Analytics catalogs and technical brochures
-
Sensyflow FMT700-P Compact
4 Pages
-
CoriolisMaster FCB100, FCH100
60 Pages
-
ProKiln GAC400
24 Pages
-
AV1 and AV2
24 Pages
-
OriMaster FPD500
24 Pages
-
AquaProbe FEA200
16 Pages
-
FTPA2000-HP260
4 Pages
-
266HSH and 266NSH
40 Pages
-
261GC, 261GG, 261GN and 261AC
44 Pages
-
LM200 Laser level transmitter
24 Pages
-
LLT100 Laser level transmitter
26 Pages
-
CoriolisMaster FCB400, FCH400
104 Pages
-
PME120-AI / PME120-AN (Contrac)
28 Pages
-
Millmate roll force systems
20 Pages
-
FTSW100 Process software
4 Pages
-
Totalflow host software
8 Pages
-
SCK
20 Pages
-
SCADAvantage™ EFM Tool
4 Pages
-
INDI-BOY DSP
8 Pages
-
CRANE-BOY / CRANE-BOYP
8 Pages
-
9QGPS5100L Tension load cell
12 Pages
-
9QGPS4500
8 Pages
-
9QGPS3100P
12 Pages
-
9QGPS2960
12 Pages
-
9QGPS2625
8 Pages
-
Ultrasonic level LST400
12 Pages
-
MB3600-HP10
5 Pages
-
MB3600-CH10
8 Pages
-
ACF5000
16 Pages
-
Diode laser analyser LS4000
4 Pages
-
Magnos28
10 Pages
-
Dynamic QR Code
4 Pages
-
EL3060
8 Pages
-
Pressductor Radial load cells
20 Pages
-
HP30
4 Pages
-
Aztec ATS430
12 Pages
-
LMS200
12 Pages
-
PGC5000
8 Pages
-
LGR-ICOS 927S
4 Pages
-
Recording and Control
20 Pages
-
2600T Pressure Transmitters
12 Pages
-
TZIDC and TZIDC-200
8 Pages
-
ProcessMaster FEP610
8 Pages
-
ALSCAN Brochure
6 Pages
-
MR Series
2 Pages
-
Emission Monitoring
8 Pages
-
Turbidity Systems 4670 Series
16 Pages
-
Sodium Monitor Model 8036
8 Pages
-
Aztec 600 Iron Analyzer
12 Pages
-
First for Liquid Analysis
16 Pages
-
ABB product catalog
32 Pages
-
process photometer
6 Pages
-
Sodium Monitor Model 8036
8 Pages