Group: ABB
Catalog excerpts
ABB MEASUREMENT & ANALY TICS | DATA SHEET LLT100 Laser level transmitter Measurement made easy
Open the catalog to page 1— Customer benefits — Main features The LLT100 is specifically made for industrial applications and harsh environments. It provides continuous, non-contact level measurement capabilities for process automation and inventory management in industries such as mining, aggregates, oil and gas, chemicals, food and beverages, power, pulp and paper, pharmaceuticals, and water and waste water. ABB brings level transmitters to the next level of non-contact measurements by packaging laser ranging technology with the features required by industrial applications. Using a pulsed laser to perform...
Open the catalog to page 3— Product configurations Base model Ideal for measuring levels of solids at up to 100 m (328 ft), and liquids at up to 30 m (98 ft) when the process is at normal pressures. This affordable and powerful level transmitter can be used in a wide variety of applications, including hazardous areas. Range Process fitting Operating temperature Process pressure Accuracy 0.5 to 100 m (2 ft to 330 ft) ASME class 150, NPS 2 in DN 50 PN 16 flat face –40 to 60 °C (–40 to 140 °F) –1 to 2 bar (29 psi) 11 mm (0.4 in) Hygienic model Ideal for food and beverage or pharmaceutical applications. Model fitted...
Open the catalog to page 4— Product configurations High pressure model Ideal for high-pressure applications. Same performance as the base model, but fitted with a choice of pressure-rated flanges. As with all models, it is certified for use in hazardous area zone 1, and its laser beam can be sent safely into zone 0. Range Process fitting Process temperature Process pressure Accuracy 0.5 to 100 m (2 to 330 ft) ASME class 150/300, NPS 2 in DN 50 PN 16/40 raised face –40 to 60 °C (–40 to 140 °F) –1 to 49.6 bar (719 psi) 11 mm (0.4 in) Accessories Configure the transmitter to a wide variety of applications. • Dust tube...
Open the catalog to page 5Rotating display with touch through-the-glass interface Industrial housing, IP67 and explosionproof class 1/division 1 (also zone 1) Pressure-rated flanges available Powered from a 4 to 20 mA loop, HART communication Eye safe, class 1 laser beam — Advantages and new features The laser transmitter measures any solid or liquid, at short or long range. A single configuration can meet a wide variety of requirements. The LLT100 can be used in challenging hazardous areas, in the presence of potentially explosive dust or gases. It can be used in class 1/division 1 (zone 1) environments. For...
Open the catalog to page 6— Solid applications A typical LLT100 application is to measure the level of solids in silos and tanks. These vessels can be found in various industries such as mining, aggregates, chemicals, food and beverages, power, pulp and paper, pharmaceuticals, etc. The high sensitivity of the LLT100 allows level measurements in tall vessels. The transmitter's narrow laser beam can be precisely aimed to circumvent obstacles. Its installation is very flexible, as the transmitter can be placed close to the wall or angled inside the vessel. Finally, material build-up on vessel walls has no effect on the...
Open the catalog to page 7— Mixer/obstruction Another challenge in the field of level measurement is obtaining reliable measurements in the presence of obstructions or mixing blades. The very narrow beam (<0.3 degrees) of the LLT100 allows installation of the instrument at almost any place on top of the vessel and its positioning between the vessel wall and the edge of the mixer, thus providing reliable measurements. When it is not possible to avoid the mixer blades, the LLT100 has advanced processing functions that can still perform the measurement reliably by efficiently tracking the real level when the mixer...
Open the catalog to page 8— Specification Measurement Range 0.5 to 30 m (2 to 100 ft) for liquids 0.5 to 100 m (2 to 330 ft) for solids 0.5 to 200 m (2 to 660 ft) for positioning applications1 Resolution 5 mm (0.2 in) Typical accuracy 11 mm (0.4 in) Measuring beam Laser wavelength: 905 nm, eye safe, Class 1 Laser beam divergence < 0.3° Housing material Powder coated aluminum (standard), 316L stainless steel (SST)(option) Dimensions (W × H × D) Universal – flat flange: 247 × 215 × 165 mm (9.7 × 8.5 × 6.5 in) Class 150 – raised flange: 240 × 242 × 154 mm (9.5 × 9.5 × 6.1 in) Class 300 – raised flange: 247 × 242 × 165...
Open the catalog to page 9— Specification Operation Display Integrated 128 × 64 pixels LCD display with through-theglass (TTG) interface Software features Volume computation, damping, filtering, thresholds/ alarms, user-defined display (with HMI) Measuring laser 905 nm near infrared pulsed semiconductor laser 7.1 μW average power output 45 W peak power output Measuring laser safety Always on IEC60825–1 Ed. 2, 2007 A Class 1 laser is safe for all conditions of use. Optical Total optical aperture 50 mm (2 in) Standard window material (flanges A and B) Tempered borosilicate glass Pressure rated window material (flanges...
Open the catalog to page 10ATEX Directive 2014/34/EU Electromagnetic compatibility Directive (EMC) 2014/30/EU Low Voltage Directive (LVD) 2014/35/EU Restriction of Hazardous Substances Directive (RoHS) 2011/65/EU ATEX, IECEx, KCs (flameproof/explosion proof/dust-ignition proof version) ATEX: FM16ATEX0032X, IECEx: FMG 16.0023X, KCs registration no: 17–AV4BO–0305X For flanges A and B: II 2 (1) G Ex db [op is T6 Ga] IIC T6…T5 Gb –50 °C ≤ Ta ≤ +75 °C…+85 °C II 2 (1) D Ex tb [op is Da] IIIC T85°C…T100°C Db –50 °C ≤ Ta ≤ +75 °C…+85 °C – IP66/ IP67 Ex db [op is T6 Ga] IIC T6…T5 Gb –50 °C ≤ Ta ≤ +75 °C…+85 °C Ex tb [op is...
Open the catalog to page 11Russia custom union Ex–мapкиpовкa ypoвнeмepoв c Флaнцaми A и B ypoвнeмepoв c Флaнцaми C, D, F и G Functional safety Random capability : Type B element, SIL 2 @ HFT = 0 ; route 1H Systematic capability : SC2 (SIL 2 capable) 1Ex db [ob isT6 Ga] IIC T6… T5 Gb X, Ex tb [op is Da] IIIC T85°C…T100°C Db X Ga/Gb Ex db [opis T6 Ga] IIC T6…T5 X, Ex tb [op is Da] IIIC T85°C
Open the catalog to page 12All ABB Measurement & Analytics catalogs and technical brochures
-
Sensyflow FMT700-P Compact
4 Pages
-
CoriolisMaster FCB100, FCH100
60 Pages
-
ProKiln GAC400
24 Pages
-
AV1 and AV2
24 Pages
-
OriMaster FPD500
24 Pages
-
AquaProbe FEA200
16 Pages
-
FTPA2000-HP260
4 Pages
-
266HSH and 266NSH
40 Pages
-
261GC, 261GG, 261GN and 261AC
44 Pages
-
LM200 Laser level transmitter
24 Pages
-
CoriolisMaster FCB400, FCH400
104 Pages
-
PME120-AI / PME120-AN (Contrac)
28 Pages
-
Millmate roll force systems
20 Pages
-
FTSW100 Process software
4 Pages
-
Totalflow host software
8 Pages
-
SCK
20 Pages
-
SCADAvantage™ EFM Tool
4 Pages
-
INDI-BOY DSP
8 Pages
-
CRANE-BOY / CRANE-BOYP
8 Pages
-
9QGPS5100L Tension load cell
12 Pages
-
9QGPS4500
8 Pages
-
9QGPS3100P
12 Pages
-
9QGPS2960
12 Pages
-
9QGPS2625
8 Pages
-
Ultrasonic level LST400
12 Pages
-
MB3600-HP10
5 Pages
-
MB3600-CH10
8 Pages
-
ACF5000
16 Pages
-
Diode laser analyser LS4000
4 Pages
-
Magnos28
10 Pages
-
Dynamic QR Code
4 Pages
-
EL3060
8 Pages
-
Pressductor Radial load cells
20 Pages
-
HP30
4 Pages
-
Aztec ATS430
12 Pages
-
LMS200
12 Pages
-
PGC5000
8 Pages
-
LGR-ICOS 927S
4 Pages
-
Recording and Control
20 Pages
-
2600T Pressure Transmitters
12 Pages
-
TZIDC and TZIDC-200
8 Pages
-
ProcessMaster FEP610
8 Pages
-
ALSCAN Brochure
6 Pages
-
MR Series
2 Pages
-
Emission Monitoring
8 Pages
-
Turbidity Systems 4670 Series
16 Pages
-
Sodium Monitor Model 8036
8 Pages
-
Aztec 600 Iron Analyzer
12 Pages
-
First for Liquid Analysis
16 Pages
-
ABB product catalog
32 Pages
-
process photometer
6 Pages
-
Sodium Monitor Model 8036
8 Pages