Product catalog summary
Customer Benefits
The LLT100 laser level transmitter is designed for industrial applications in harsh environments, providing continuous, non-contact level measurement for process automation and inventory management. It is suitable for industries such as mining, oil and gas, and pharmaceuticals. Key benefits include precise measurement of solids and liquids, low cost of ownership with fast installation, and no maintenance required.
Main Features
The LLT100 uses laser ranging technology for accurate distance measurements, powered by a 4 to 20 mA current loop. It is available in aluminum or stainless steel housing and can operate in hazardous, high-pressure, and high-temperature environments. Features include easy setup, a graphical user interface, and reliable performance in dust and fog.
Product Configurations
  • Base Model: Suitable for measuring solids up to 100 m and liquids up to 30 m, with a process pressure range of -1 to 2 bar.
  • Hygienic Model: Ideal for food and pharmaceutical applications, featuring a 4-inch triclover clamp interface.
  • High Pressure Model: Designed for high-pressure applications, with pressure-rated flanges and a process pressure range up to 49.6 bar.
Accessories
Includes dust tube, purge ring, cooling tube, heated window, flange adapters, and more to enhance functionality in various applications.
Functions
Features a rotating display with a touch interface, industrial housing with IP67 and explosion-proof ratings, and is powered from a 4 to 20 mA loop with HART communication.
Advantages and New Features
The LLT100 is versatile, capable of measuring solids and liquids in hazardous areas, and can be configured for zone-rated environments. It includes features for dust and high-temperature applications, such as a dust tube and cooling tube.
Applications
  • Solid Applications: Measures levels in silos and tanks, with high sensitivity and flexible installation.
  • Liquid Applications: Detects any liquid, with options to prevent condensation and align the laser beam accurately.
  • Mixer/Obstruction: Provides reliable measurements even with obstructions or mixing blades.
  • Positioning: Offers accurate position measurement for moving objects like wagons and cranes.
Specifications
Measurement range varies for liquids, solids, and positioning applications. The device operates in temperatures from -40 to 60 °C and supports various process pressures. It features a laser wavelength of 905 nm, is eye-safe, and has a beam divergence of less than 0.3 degrees.
Approvals
The LLT100 complies with multiple international standards and directives, including CE, ATEX, IECEx, and FM approvals for use in hazardous locations.
Certificate and Standards
The document outlines the certification and standards for refractometers and energy-absorbing optical sensors used in milk and milk products. It includes safety certifications such as TÜV and compliance with various ABNT NBR IEC standards, including 60079 series and 60529, as well as INMETRO regulations.
Specifications
The LLT100 Laser Level Transmitter is detailed with specifications for different configurations, including cemented and fused glass windows. It operates within temperature ranges of -50°C to +85°C and complies with safety standards for explosive environments.
Approvals and Safety
The device has multiple safety approvals, including EAC and SIL 2 certification for functional safety. It adheres to IEC 61508 standards for safety integrity levels.
Dimensions and Figures
Several figures illustrate the dimensions of the LLT100 with various flange types, including universal, class 150, class 300, and PN16/PN40 flanges. Dimensions are provided in both millimeters and inches.
Interface and Accessories
The document describes the HART terminal interface options, both with and without heater options, and lists various accessories such as dust tubes, purge rings, cooling tubes, and adjustable brackets.
Ordering Information
Detailed ordering information is provided, including body material options, process flange types, communication protocols, display options, and explosion protection certifications. Additional accessories and options for customization are also listed.
Contact and Legal Information
Contact details for ABB Inc. are provided, along with legal disclaimers regarding the document's content and reproduction rights.
See more

Catalog excerpts

LLT100 Laser level transmitter-1

ABB MEASUREMENT & ANALY TICS | DATA SHEET LLT100 Laser level transmitter Measurement made easy

 Open the catalog to page 1
LLT100 Laser level transmitter-3

— Customer benefits — Main features The LLT100 is specifically made for industrial applications and harsh environments. It provides continuous, non-contact level measurement capabilities for process automation and inventory management in industries such as mining, aggregates, oil and gas, chemicals, food and beverages, power, pulp and paper, pharmaceuticals, and water and waste water. ABB brings level transmitters to the next level of non-contact measurements by packaging laser ranging technology with the features required by industrial applications. Using a pulsed laser to perform time-of-flight...

 Open the catalog to page 3
LLT100 Laser level transmitter-4

— Product configurations Base model Ideal for measuring levels of solids at up to 100 m (328 ft), and liquids at up to 30 m (98 ft) when the process is at normal pressures. This affordable and powerful level transmitter can be used in a wide variety of applications, including hazardous areas. Range Process fitting Operating temperature Process pressure Accuracy 0.5 to 100 m (2 ft to 330 ft) ASME class 150, NPS 2 in DN 50 PN 16 flat face –40 to 60 °C (–40 to 140 °F) –1 to 2 bar (29 psi) 11 mm (0.4 in) Hygienic model Ideal for food and beverage or pharmaceutical applications. Model fitted with...

 Open the catalog to page 4
LLT100 Laser level transmitter-5

— Product configurations High pressure model Ideal for high-pressure applications. Same performance as the base model, but fitted with a choice of pressure-rated flanges. As with all models, it is certified for use in hazardous area zone 1, and its laser beam can be sent safely into zone 0. Range Process fitting Process temperature Process pressure Accuracy 0.5 to 100 m (2 to 330 ft) ASME class 150/300, NPS 2 in DN 50 PN 16/40 raised face –40 to 60 °C (–40 to 140 °F) –1 to 49.6 bar (719 psi) 11 mm (0.4 in) Accessories Configure the transmitter to a wide variety of applications. • Dust tube •...

 Open the catalog to page 5
LLT100 Laser level transmitter-6

Rotating display with touch through-the-glass interface Industrial housing, IP67 and explosionproof class 1/division 1 (also zone 1) Pressure-rated flanges available Powered from a 4 to 20 mA loop, HART communication Eye safe, class 1 laser beam — Advantages and new features The laser transmitter measures any solid or liquid, at short or long range. A single configuration can meet a wide variety of requirements. The LLT100 can be used in challenging hazardous areas, in the presence of potentially explosive dust or gases. It can be used in class 1/division 1 (zone 1) environments. For zone-rated...

 Open the catalog to page 6
LLT100 Laser level transmitter-7

— Solid applications A typical LLT100 application is to measure the level of solids in silos and tanks. These vessels can be found in various industries such as mining, aggregates, chemicals, food and beverages, power, pulp and paper, pharmaceuticals, etc. The high sensitivity of the LLT100 allows level measurements in tall vessels. The transmitter's narrow laser beam can be precisely aimed to circumvent obstacles. Its installation is very flexible, as the transmitter can be placed close to the wall or angled inside the vessel. Finally, material build-up on vessel walls has no effect on the measurement,...

 Open the catalog to page 7
LLT100 Laser level transmitter-8

— Mixer/obstruction Another challenge in the field of level measurement is obtaining reliable measurements in the presence of obstructions or mixing blades. The very narrow beam (<0.3 degrees) of the LLT100 allows installation of the instrument at almost any place on top of the vessel and its positioning between the vessel wall and the edge of the mixer, thus providing reliable measurements. When it is not possible to avoid the mixer blades, the LLT100 has advanced processing functions that can still perform the measurement reliably by efficiently tracking the real level when the mixer blades...

 Open the catalog to page 8
LLT100 Laser level transmitter-9

— Specification Measurement Range 0.5 to 30 m (2 to 100 ft) for liquids 0.5 to 100 m (2 to 330 ft) for solids 0.5 to 200 m (2 to 660 ft) for positioning applications1 Resolution 5 mm (0.2 in) Typical accuracy 11 mm (0.4 in) Measuring beam Laser wavelength: 905 nm, eye safe, Class 1 Laser beam divergence < 0.3° Housing material Powder coated aluminum (standard), 316L stainless steel (SST)(option) Dimensions (W × H × D) Universal – flat flange: 247 × 215 × 165 mm (9.7 × 8.5 × 6.5 in) Class 150 – raised flange: 240 × 242 × 154 mm (9.5 × 9.5 × 6.1 in) Class 300 – raised flange: 247 × 242 × 165 mm...

 Open the catalog to page 9
LLT100 Laser level transmitter-10

— Specification Operation Display Integrated 128 × 64 pixels LCD display with through-theglass (TTG) interface Software features Volume computation, damping, filtering, thresholds/ alarms, user-defined display (with HMI) Measuring laser 905 nm near infrared pulsed semiconductor laser 7.1 μW average power output 45 W peak power output Measuring laser safety Always on IEC60825–1 Ed. 2, 2007 A Class 1 laser is safe for all conditions of use. Optical Total optical aperture 50 mm (2 in) Standard window material (flanges A and B) Tempered borosilicate glass Pressure rated window material (flanges C,...

 Open the catalog to page 10
LLT100 Laser level transmitter-11

ATEX Directive 2014/34/EU Electromagnetic compatibility Directive (EMC) 2014/30/EU Low Voltage Directive (LVD) 2014/35/EU Restriction of Hazardous Substances Directive (RoHS) 2011/65/EU ATEX, IECEx, KCs (flameproof/explosion proof/dust-ignition proof version) ATEX: FM16ATEX0032X, IECEx: FMG 16.0023X, KCs registration no: 17–AV4BO–0305X For flanges A and B: II 2 (1) G Ex db [op is T6 Ga] IIC T6…T5 Gb –50 °C ≤ Ta ≤ +75 °C…+85 °C II 2 (1) D Ex tb [op is Da] IIIC T85°C…T100°C Db –50 °C ≤ Ta ≤ +75 °C…+85 °C – IP66/ IP67 Ex db [op is T6 Ga] IIC T6…T5 Gb –50 °C ≤ Ta ≤ +75 °C…+85 °C Ex tb [op is Da]...

 Open the catalog to page 11
LLT100 Laser level transmitter-12

Russia custom union Ex–мapкиpовкa ypoвнeмepoв c Флaнцaми A и B ypoвнeмepoв c Флaнцaми C, D, F и G Functional safety Random capability : Type B element, SIL 2 @ HFT = 0 ; route 1H Systematic capability : SC2 (SIL 2 capable) 1Ex db [ob isT6 Ga] IIC T6… T5 Gb X, Ex tb [op is Da] IIIC T85°C…T100°C Db X Ga/Gb Ex db [opis T6 Ga] IIC T6…T5 X, Ex tb [op is Da] IIIC T85°C

 Open the catalog to page 12

All ABB Measurement & Analytics catalogs and technical brochures

  1. ProKiln GAC400

    24  Pages

  2. AV1 and AV2

    24  Pages

  3. SCK

    20  Pages

  4. INDI-BOY DSP

    8  Pages

  5. 9QGPS4500

    8  Pages

  6. 9QGPS3100P

    12  Pages

  7. 9QGPS2960

    12  Pages

  8. 9QGPS2625

    8  Pages

  9. MB3600-HP10

    5  Pages

  10. MB3600-CH10

    8  Pages

  11. ACF5000

    16  Pages

  12. Magnos28

    10  Pages

  13. EL3060

    8  Pages

  14. HP30

    4  Pages

  15. Aztec ATS430

    12  Pages

  16. LMS200

    12  Pages

  17. PGC5000

    8  Pages

  18. LGR-ICOS 927S

    4  Pages

  19. MR Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.