FTPA2000-HP260
4Pages

{{requestButtons}}

Catalog excerpts

FTPA2000-HP260 - 1

Fiber-optic Multichannel Process FT-NIR Analyzer Platform for Hydrocarbon and Petrochemical Applications Standard Configuration for Safe-Area (pricing for Hazardous Area enclosure and Certification of Analyzer available as Option) The FTPA2000-HP260 includes: − − Process FT-IR FTPA2000-HP260, with integrated air-conditioned rack-mount cabinet designed for safe area mounting. Connection to DCS via MODBUS or OPC. Rack-mount controller with FTSW100 software − − Requires remote fiber-optic temperature controlled sample cell enclosure, or in-line transmission probes. See price list for selection −− Requires fast loop sample system. See price list for selection − − Requires Wash/reference fluid system. See price list for selection − − Requires pair FCP300 f/optic cables, for use in 1st / 2nd Overtone / 2nd Combination region, 5500-9500 cm-1. See price list for selection −− Requires selection of appropriate InGaAs detectors for application and number of channels. See price list for selection −− Turn-key Calibration and Modelling on request at extra cost. − − Requires startup plan sold separately −− Additional application and project support, training and performance audit services available on request −− Hazardous area packaging options available as NEC/CSA Class 1 Disvision 2 or ATEX Category II 2G (EEx pem [ib] IIC T4, for hazardous area operation FTPA2000-HP260 Fiber-Optic Process FT-IR Analyzer for Hydrocarbon Streams NIR optics covering the 3800 cm -1 to 12,000 cm-1 range, 8 output channels Includes: −− FT-IR Multichannel Process Spectrometer covering the 12,000 cm -1 to 3800 cm-1 range (BK7 optics) with 8 channels fiber optics output − − Ethernet connection − − FTSW100 software, remote access software − − Startup and Installation sold separately Notes: − − To be installed into a temperature controlled and dry environment. General purpose classified area (hazardous area packaging available) −− Operating temperature range: 0°C to 40°C, stable within ±5°C − − Humidity range: 5% to 95% non-condensing −− FTPA2000-260 Purge assembly, to be used with (SDG1000G) membrane dryer kit. Requires customer-supplied oil free, dry instrumentation air between 2 and 5 L/min − − Includes High Sensitivity Room-temperature InGaAs range 4800 to 11,000 cm -1 (2100 to 900 nm) with SMA connector for FTPA2000-200 series Rack Mount Cabinet with IBM 1U 19 in. rack mount computer Includes: − − Keyboard slide − − Flat screen LCD color monitor −− Industrial 19 in. Rack cabinet, with Air Conditioning, 110/220 VAC version, Nema 12, 69 in.(1753 mm) tall X 24 in. (610 mm) wide X 32 in. (813 mm) deep −− For FTPA2000-200 Series Process FT-IR Spectrometer, RACKPC industrial computer and available space for one extra FTPA2000-200 Series Process FT-IR Spectrometer or one ACC129 and I/O’s. −

Open the catalog to page 1
FTPA2000-HP260 - 2

Fibre-optic Multichannel Process FT-NIR Analyzer Platform Industrial grade FT-NIR spectrometer with BK7 optics for near IR operation −− Spectral range from 12,000 to 3800 cm-1 (operational range depends on choice of fibres and detectors) −− Resolution variable from 1 to 64 cm -1, in steps of 2× −− Best resolution 0.7 cm -1 (unapodized) − − Wavenumber reproducibility ±0.04 cm -1 ( based on water vapor line at 7299.86 cm -1) − − Wavenumber repeatability ±0.001 cm -1 − − Peak signal-to-RMS-noise ratio typically 30,000:1 for open beam, 1-min scan time, 4 cm-1 resolution − − Noise less than 15...

Open the catalog to page 2
FTPA2000-HP260 - 3

−− Four (4) 750-513: 2-channel digital relay output module (NO dry contact, 30 VDC, 250 VAC, 2 A) for: (e.g.: System Alarm, System Warning, System Fault, Off-line/On-Line, SSO control, etc.) Notes: − − Does not include 4-20 mA outputs for property outputs − − Additional line items for additional modules should be selected to complete the I/O Package if required − − Pre-mounted onto a DIN rail Hardwired − − Digital input (typically volt free contact) − − Digital output (typically dry contact relay) − − Analog input and output (typically 4-20 mA Modbus − − RS422/485 serial link − − Modbus...

Open the catalog to page 3
FTPA2000-HP260 - 4

ABB Analytical Measurement 585 Charest Blvd East, suite 300 Quebec, (Quebec) G1K 9H4 Canada Phone: +1 418-877-2944 Email: ftir@ca.abb.com www.abb.com/analytical Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure...

Open the catalog to page 4

All ABB Measurement & Analytics catalogs and technical brochures

  1. ProKiln GAC400

    24 Pages

  2. AV1 and AV2

    24 Pages

  3. SCK

    20 Pages

  4. INDI-BOY DSP

    8 Pages

  5. 9QGPS4500

    8 Pages

  6. 9QGPS3100P

    12 Pages

  7. 9QGPS2960

    12 Pages

  8. 9QGPS2625

    8 Pages

  9. MB3600-HP10

    5 Pages

  10. MB3600-CH10

    8 Pages

  11. ACF5000

    16 Pages

  12. Magnos28

    10 Pages

  13. EL3060

    8 Pages

  14. HP30

    4 Pages

  15. Aztec ATS430

    12 Pages

  16. LMS200

    12 Pages

  17. PGC5000

    8 Pages

  18. MR Series

    2 Pages