Group: ABB
Catalog excerpts
Advanced solutions for every measuring task Emission Monitoring
Open the catalog to page 1Your task – our solution If that is what you are looking for – then ABB is the partner you want. Using performancetested, standardized modules, we can develop cost effective solutions tailored to meet all your special requirements: From sample conditioning to analytical equipment, from system controls to turn-key solutions. Thanks to our ABB worldwide network, you can be sure that our solutions will also fulfill any regional requirements. And our analyzer systems can either be integrated with your existing equipment or supplied as a unified solution, for example with integrated data...
Open the catalog to page 2ABB analyzer systems – an overview: AO2000 High-performance measuring technology Standardized analyzer components Compact system design Easy integration of components Standard interfaces for IT and process automation networks Typical sample components: CO, NO, SO2, O2 NOX in single digit ppm ranges ACN For emission monitoring according to local regulations Economically priced analyzer system for standard applications Simultaneous determination of up to five sample components e.g. CO, NO, SO2, Ctotal and O2 Calibration without test gas cylinders Maintenance interval 1 year Complete remote...
Open the catalog to page 3For every application the right analyzer system Performance-tested analyzers – AO2000 The modular components of the AO2000 series form the basis for a wide range of ABB analyzer systems. What makes the AO2000 so unique is its high-performance measuring technology and its use of standardized modules. These analyzer components are the keys to the system’s success and are available for use with different measurement principles. With the AO2000 multianalyzer system – six sample components can be measured and up to four analyzer modules using different measurement techniques can be connected via...
Open the catalog to page 4Controlling complex applications – ACF-NT The ACF-NT is ideal for monitoring complex applications, such as: Domestic and hazardous chemical waste incinerators, sewage sludge incinerators, cement plants and power plants. The system is based on ABB’s FTIR spectrometer and it offers the high selectivity of FTIR technology as well as the ability to accommodate additional infrared components. This monitoring system is perfectly suited for the measurement of emissions according to the 17th BImSchV (German Federal Immission Control Ordinance) such as: HCl, CO, NO and SO2 as well as NH3, H2O, CO2,...
Open the catalog to page 5Certificates ABB analyzers have been approved for industrial use by most certifying authorities – around the world. Including: The 13th, 17th, 27th, 30th and 31st BImSchV and TA Luft for emission measurements in Germany for ACF-NT EPA requirements in the USA mCERT requirements in the UK JQA requirements in Japan Provisional Pattern Approval requirements in China In addition, ABB analyzers have also received special certifications for use in hazardous areas. Such as: ATEX certificate for Category II 2G, II 3G CSA certificate for Class I, Division 2 Analyzer technology is our strength...
Open the catalog to page 6names Uras, Limas, Caldos and Magnos have enjoyed worldwide acclaim and stand for the highest efficiency. Today, more than 30,000 of these analyzers have been installed in virtually every industry – around the world. Consulting Worldwide, our field support experts stand ready to provide initial assistance for any problem you might have. Then our specialists are put to work for you to deliver concrete solutions, quickly and efficiently. Project planning and engineering ABB develops comprehensive analyzer systems based on our extensive experience. To satisfy your individual requirements,...
Open the catalog to page 7ABB Automation GmbH Analytical Stierstädter Str. 5 60488 Frankfurt GERMANY analytical-mkt.deapr@de.abb.com www.abb.com/analytical 50/23-04 EN 10.05 ABB continuously optimizes its products, therefore the technical data in this document is subject to change. Printed in the Fed. Rep. of Germany (10.2005) © ABB 2005
Open the catalog to page 8All ABB Measurement & Analytics catalogs and technical brochures
-
Sensyflow FMT700-P Compact
4 Pages
-
CoriolisMaster FCB100, FCH100
60 Pages
-
ProKiln GAC400
24 Pages
-
AV1 and AV2
24 Pages
-
OriMaster FPD500
24 Pages
-
AquaProbe FEA200
16 Pages
-
FTPA2000-HP260
4 Pages
-
266HSH and 266NSH
40 Pages
-
261GC, 261GG, 261GN and 261AC
44 Pages
-
LM200 Laser level transmitter
24 Pages
-
LLT100 Laser level transmitter
26 Pages
-
CoriolisMaster FCB400, FCH400
104 Pages
-
PME120-AI / PME120-AN (Contrac)
28 Pages
-
Millmate roll force systems
20 Pages
-
FTSW100 Process software
4 Pages
-
Totalflow host software
8 Pages
-
SCK
20 Pages
-
SCADAvantage™ EFM Tool
4 Pages
-
INDI-BOY DSP
8 Pages
-
CRANE-BOY / CRANE-BOYP
8 Pages
-
9QGPS5100L Tension load cell
12 Pages
-
9QGPS4500
8 Pages
-
9QGPS3100P
12 Pages
-
9QGPS2960
12 Pages
-
9QGPS2625
8 Pages
-
Ultrasonic level LST400
12 Pages
-
MB3600-HP10
5 Pages
-
MB3600-CH10
8 Pages
-
ACF5000
16 Pages
-
Diode laser analyser LS4000
4 Pages
-
Magnos28
10 Pages
-
Dynamic QR Code
4 Pages
-
EL3060
8 Pages
-
Pressductor Radial load cells
20 Pages
-
HP30
4 Pages
-
Aztec ATS430
12 Pages
-
LMS200
12 Pages
-
PGC5000
8 Pages
-
LGR-ICOS 927S
4 Pages
-
Recording and Control
20 Pages
-
2600T Pressure Transmitters
12 Pages
-
TZIDC and TZIDC-200
8 Pages
-
ProcessMaster FEP610
8 Pages
-
ALSCAN Brochure
6 Pages
-
MR Series
2 Pages
-
Turbidity Systems 4670 Series
16 Pages
-
Sodium Monitor Model 8036
8 Pages
-
Aztec 600 Iron Analyzer
12 Pages
-
First for Liquid Analysis
16 Pages
-
ABB product catalog
32 Pages
-
process photometer
6 Pages
-
Sodium Monitor Model 8036
8 Pages