—ME ASURE ME NT & AN AL YT ICS | D AT A SHE ET ABB CoriolisMaster FCB400, FCH400 Coriolis mass flowmeter
Open the catalog to page 1FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — Measurement made easy High-precision measurement of mass and volume flow, density, temperature and concentration with just one device — Up to five modular I/Os • Optional plug-in cards • Automatic firmware update • Integrated solutions for filling operations and concentration measurement — SmartSensor • All digital solution • Measuring device intelligence located directly in the sensor • Lower pressure loss — Integrated VeriMass device verification and diagnosis • Predictive maintenance in the process • Extended maintenance...
Open the catalog to page 2FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — Overview – models 1 Sensor (integral mount design, dual-compartment housing) 3 Sensor (remote mount design) 2 Sensor (integral mount design, single-compartment housing) Figure 1: Designs Sensor Model Integral mount design, remote mount design Measuring accuracy for liquids Mass flow* Volume flow* Measuring accuracy for gases* Permissible measuring medium temperature Tmedium Process connection Flange DIN 2501 / EN 1092-1 Threaded pipe connection conforming to DN 10 to 100 (⅜ to 4 in) Other connections Wetted material Stainless...
Open the catalog to page 3FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … Overview – models Figure 2: Transmitter with remote mount design Transmitter Chassis Integral mount design (see Figure 1, pos. 1 and 2), remote mount design. Cable length Maximum 200 m (656 ft), with remote mount design only Power supply Outputs in basic version Current output: 4 to 20 mA active or passive Digital output 1: passive, configurable as pulse, frequency or switch output Digital output 2: passive, configurable as pulse or switch output Additional optional outputs The transmitter has two slots in which plug-in cards...
Open the catalog to page 4FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — General data Device description SIL-functional safety The CoriolisMaster FCB400, FCH400 is the cost-effective and easy ABB mass flowmeter with a new modular transmitter. Verification in accordance with IEC 61508 2, route Component Type The CoriolisMaster FCB400, FCH400 operates in accordance with the Coriolis principle. The design offers the following benefits: • Space-saving, robust design. • Variety of process connections. • Modular, flexible output concept. Transmitter with digital signal processor (DSP) The transmitter...
Open the catalog to page 5FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … General data FillMass batch function Only for FCB450 / FCH450 Start Start of the filling process via field bus or digital input 3 Start / stop fill operation (digital input or field bus) 4 Fill valve 5 Filling tank State of the digital output for the fill valve Q Flow rate VO Valve open (filling started) VC Valve closed (fill quantity reached) t1 Valve closing time t2 Overrun time Figure 3: FillMass fill function The integrated FillMass fill function allows filling processes with filling times of > 3 seconds. For this purpose,...
Open the catalog to page 6FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N Concentration measurement DensiMass Only for FCB450 / FCH450 The transmitter can calculate the current concentration from the measured density and temperature using concentration matrices. The following concentration matrices are preconfigured in the transmitter as standard: • Concentration of sodium hydroxide in water • Concentration of alcohol in water • Concentration of sugar in water • Concentration of maize starch in water • Concentration of wheat starch in water In addition, the user can enter two user-defined matrices:...
Open the catalog to page 7FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … General data Enhanced Coriolis Control (ECC)function The Enhanced Coriolis Control (ECC)function has been specially developed for demanding applications, such as: • Liquids with gas phase • Liquids with rapidly changing densities • Fill operations with surge phases at the beginning or end • Liquids with high viscosity After the ECC function is activated, the device applies a particularly quick control algorithm to control the oscillating tubes in the device and therefore provide significantly better behavior in the applications...
Open the catalog to page 8FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — Flowmeter sensor VeriMass erosion monitor General installation conditions The integrated diagnosis function VeriMass allows the status of the meter tube to be monitored. This enables changes due to material erosion and the formation of deposits on the meter tube walls to be identified at an early stage. If the set limit value is exceeded, an alarm is triggered, for example via the programmable digital output or HART, depending on the configuration. The limit value for the erosion monitor can be set either automatically or manually....
Open the catalog to page 9FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … Flowmeter sensor Brackets and supports No special supports or damping are required for the device when the device is used and installed as intended. In systems designed in accordance with ‘Best Practice’, the forces acting on the device are already sufficiently absorbed. This is also true of devices installed in series or in parallel. For heavier devices, it is advisable to use additional supports / brackets on site. Doing this prevents damage to the process connections and piping from lateral forces. Please observe the following...
Open the catalog to page 10FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N For vertical installation in a riser, no special measures are required. B For vertical installation in a downpipe, a piping constriction or an orifice must be installed below the sensor. Doing this prevents the sensor from draining during the measurement. Gaseous measuring media Horizontal installation Observe the following points to avoid measuring errors: • Gases must be dry and free of liquids and condensates. • Avoid the accumulation of liquids and the formation of condensate in the meter tube. • During operation, there must...
Open the catalog to page 114 Pages
60 Pages
24 Pages
24 Pages
24 Pages
16 Pages
4 Pages
40 Pages
44 Pages
24 Pages
26 Pages
28 Pages
20 Pages
4 Pages
8 Pages
20 Pages
4 Pages
8 Pages
8 Pages
12 Pages
8 Pages
12 Pages
12 Pages
8 Pages
12 Pages
5 Pages
8 Pages
16 Pages
4 Pages
10 Pages
4 Pages
8 Pages
20 Pages
4 Pages
12 Pages
12 Pages
8 Pages
4 Pages
20 Pages
12 Pages
8 Pages
8 Pages
6 Pages
2 Pages
8 Pages
16 Pages
8 Pages
12 Pages
16 Pages
32 Pages
6 Pages
8 Pages