—ME ASURE ME NT & AN AL YT ICS | D AT A SHE ET ABB CoriolisMaster FCB400, FCH400 Coriolis mass flowmeter
Open the catalog to page 1FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — Measurement made easy High-precision measurement of mass and volume flow, density, temperature and concentration with just one device — Up to five modular I/Os • Optional plug-in cards • Automatic firmware update • Integrated solutions for filling operations and concentration measurement — SmartSensor • All digital solution • Measuring device intelligence located directly in the sensor • Lower pressure loss — Integrated VeriMass device verification and diagnosis • Predictive maintenance in the process • Extended...
Open the catalog to page 2FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — Overview – models 1 Sensor (integral mount design, dual-compartment housing) 3 Sensor (remote mount design) 2 Sensor (integral mount design, single-compartment housing) Figure 1: Designs Sensor Model Integral mount design, remote mount design Measuring accuracy for liquids Mass flow* Volume flow* Measuring accuracy for gases* Permissible measuring medium temperature Tmedium Process connection Flange DIN 2501 / EN 1092-1 Threaded pipe connection conforming to DN 10 to 100 (⅜ to 4 in) Other connections Wetted material...
Open the catalog to page 3FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … Overview – models Figure 2: Transmitter with remote mount design Transmitter Chassis Integral mount design (see Figure 1, pos. 1 and 2), remote mount design. Cable length Maximum 200 m (656 ft), with remote mount design only Power supply Outputs in basic version Current output: 4 to 20 mA active or passive Digital output 1: passive, configurable as pulse, frequency or switch output Digital output 2: passive, configurable as pulse or switch output Additional optional outputs The transmitter has two slots in which plug-in...
Open the catalog to page 4FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — General data Device description SIL-functional safety The CoriolisMaster FCB400, FCH400 is the cost-effective and easy ABB mass flowmeter with a new modular transmitter. Verification in accordance with IEC 61508 2, route Component Type The CoriolisMaster FCB400, FCH400 operates in accordance with the Coriolis principle. The design offers the following benefits: • Space-saving, robust design. • Variety of process connections. • Modular, flexible output concept. Transmitter with digital signal processor (DSP) The...
Open the catalog to page 5FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … General data FillMass batch function Only for FCB450 / FCH450 Start Start of the filling process via field bus or digital input 3 Start / stop fill operation (digital input or field bus) 4 Fill valve 5 Filling tank State of the digital output for the fill valve Q Flow rate VO Valve open (filling started) VC Valve closed (fill quantity reached) t1 Valve closing time t2 Overrun time Figure 3: FillMass fill function The integrated FillMass fill function allows filling processes with filling times of > 3 seconds. For this...
Open the catalog to page 6FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N Concentration measurement DensiMass Only for FCB450 / FCH450 The transmitter can calculate the current concentration from the measured density and temperature using concentration matrices. The following concentration matrices are preconfigured in the transmitter as standard: • Concentration of sodium hydroxide in water • Concentration of alcohol in water • Concentration of sugar in water • Concentration of maize starch in water • Concentration of wheat starch in water In addition, the user can enter two user-defined...
Open the catalog to page 7FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … General data Enhanced Coriolis Control (ECC)function The Enhanced Coriolis Control (ECC)function has been specially developed for demanding applications, such as: • Liquids with gas phase • Liquids with rapidly changing densities • Fill operations with surge phases at the beginning or end • Liquids with high viscosity After the ECC function is activated, the device applies a particularly quick control algorithm to control the oscillating tubes in the device and therefore provide significantly better behavior in the...
Open the catalog to page 8FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — Flowmeter sensor VeriMass erosion monitor General installation conditions The integrated diagnosis function VeriMass allows the status of the meter tube to be monitored. This enables changes due to material erosion and the formation of deposits on the meter tube walls to be identified at an early stage. If the set limit value is exceeded, an alarm is triggered, for example via the programmable digital output or HART, depending on the configuration. The limit value for the erosion monitor can be set either automatically or...
Open the catalog to page 9FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … Flowmeter sensor Brackets and supports No special supports or damping are required for the device when the device is used and installed as intended. In systems designed in accordance with ‘Best Practice’, the forces acting on the device are already sufficiently absorbed. This is also true of devices installed in series or in parallel. For heavier devices, it is advisable to use additional supports / brackets on site. Doing this prevents damage to the process connections and piping from lateral forces. Please observe the...
Open the catalog to page 10FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N For vertical installation in a riser, no special measures are required. B For vertical installation in a downpipe, a piping constriction or an orifice must be installed below the sensor. Doing this prevents the sensor from draining during the measurement. Gaseous measuring media Horizontal installation Observe the following points to avoid measuring errors: • Gases must be dry and free of liquids and condensates. • Avoid the accumulation of liquids and the formation of condensate in the meter tube. • During operation, there...
Open the catalog to page 11All ABB Measurement & Analytics catalogs and technical brochures
-
Sensyflow FMT700-P Compact
4 Pages
-
CoriolisMaster FCB100, FCH100
60 Pages
-
ProKiln GAC400
24 Pages
-
AV1 and AV2
24 Pages
-
OriMaster FPD500
24 Pages
-
AquaProbe FEA200
16 Pages
-
FTPA2000-HP260
4 Pages
-
266HSH and 266NSH
40 Pages
-
261GC, 261GG, 261GN and 261AC
44 Pages
-
LM200 Laser level transmitter
24 Pages
-
LLT100 Laser level transmitter
26 Pages
-
PME120-AI / PME120-AN (Contrac)
28 Pages
-
Millmate roll force systems
20 Pages
-
FTSW100 Process software
4 Pages
-
Totalflow host software
8 Pages
-
SCK
20 Pages
-
SCADAvantage™ EFM Tool
4 Pages
-
INDI-BOY DSP
8 Pages
-
CRANE-BOY / CRANE-BOYP
8 Pages
-
9QGPS5100L Tension load cell
12 Pages
-
9QGPS4500
8 Pages
-
9QGPS3100P
12 Pages
-
9QGPS2960
12 Pages
-
9QGPS2625
8 Pages
-
Ultrasonic level LST400
12 Pages
-
MB3600-HP10
5 Pages
-
MB3600-CH10
8 Pages
-
ACF5000
16 Pages
-
Diode laser analyser LS4000
4 Pages
-
Magnos28
10 Pages
-
Dynamic QR Code
4 Pages
-
EL3060
8 Pages
-
Pressductor Radial load cells
20 Pages
-
HP30
4 Pages
-
Aztec ATS430
12 Pages
-
LMS200
12 Pages
-
PGC5000
8 Pages
-
LGR-ICOS 927S
4 Pages
-
Recording and Control
20 Pages
-
2600T Pressure Transmitters
12 Pages
-
TZIDC and TZIDC-200
8 Pages
-
ProcessMaster FEP610
8 Pages
-
ALSCAN Brochure
6 Pages
-
MR Series
2 Pages
-
Emission Monitoring
8 Pages
-
Turbidity Systems 4670 Series
16 Pages
-
Sodium Monitor Model 8036
8 Pages
-
Aztec 600 Iron Analyzer
12 Pages
-
First for Liquid Analysis
16 Pages
-
ABB product catalog
32 Pages
-
process photometer
6 Pages
-
Sodium Monitor Model 8036
8 Pages