CoriolisMaster FCB100, FCH100
60Pages

{{requestButtons}}

Catalog excerpts

CoriolisMaster FCB100, FCH100 - 1

—ME ASURE ME NT & AN AL YT ICS | D AT A SHE ET ABB CoriolisMaster FCB100, FCH100 Coriolis mass flowmeter

Open the catalog to page 1
CoriolisMaster FCB100, FCH100 - 2

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J — Measurement made easy Compact device for high-precision measurement of mass and volume flow, density, temperature and concentration with just one device — The ideal transmitter for system integration • Modbus for quick and comprehensive communication • Two fast digital outputs that can be configured as pulse outputs, frequency outputs or binary outputs • Lower pressure loss, self-draining • Global approvals for explosion protection • MID / OIML approval for legal metrology — Integrated VeriMass device...

Open the catalog to page 2
CoriolisMaster FCB100, FCH100 - 3

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J — Overview – models Model number Other connections Wetted material Stainless steel 1.4435 or 1.4404 (AISI 316L), nickel-alloy Stainless steel, polished 1.4404 (AISI 316L) or 1.4435 Process connections Approvals and certificates Explosion protection ATEX / IECEx Explosion protection conforming to cFMus Class I Div. 1, Class I Div. 2, Zone 0, 1, 2, 21 Class I Div. 1, Class I Div. 2, Zone 0, 1, 2, 21 Hygiene approvals Legal metrology OIML R117, MID, devices for legal metrology in accordance with API / AGA...

Open the catalog to page 3
CoriolisMaster FCB100, FCH100 - 4

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J — … Overview – models Model number Mass flow* Volume flow* Measuring accuracy for liquids Measuring accuracy for gases* Permissible measuring medium Permissible ambient temperature Power supply IP rating in accordance with EN 60529 IP 65 / IP 67 / IP 68 (immersion depth: 5 m), NEMA 4X Outputs in serial production Digital output 1: passive Digital output 2: passive External output zero return External totalizer reset Flow measurement in forward flow and reverse flow direction Empty pipe detection Yes, based on...

Open the catalog to page 4
CoriolisMaster FCB100, FCH100 - 5

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J — General data Device description The CoriolisMaster FCB100, FCH100 is the low-cost and simple ABB mass flowmeter with the new DSP transmitter. The device is equipped with a Modbus® interface and two fast digital outputs that can be configured as pulse, frequency or binary outputs. The CoriolisMaster FCB100, FCH100 operates in accordance with the Coriolis principle. The design offers the following benefits: • Space-saving, robust design. • Variety of process connections. • Two digital outputs. • Communication...

Open the catalog to page 5
CoriolisMaster FCB100, FCH100 - 6

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J — … General data FillMass batch function Only for FCB150 / FCH150 Supply tank Start Start of the filling operation via Modbus Start / stop fill operation (Modbus) Fill valve Filling tank State of the digital output for the fill valve Q Flow rate VO Valve open (filling started) VC Valve closed (fill quantity reached) t1 Valve closing time t2 Overrun time FillMass fill function The integrated FillMass fill function allows filling operations with filling times of > 3 s. For this purpose, the filling quantity is...

Open the catalog to page 6
CoriolisMaster FCB100, FCH100 - 7

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J Concentration measurement DensiMass Only for FCB150 / FCH150 The transmitter can calculate the current concentration from the measured density and temperature using concentration matrices. The following concentration matrices are preconfigured in the transmitter as standard: • Concentration of sodium hydroxide in water • Concentration of alcohol in water • Concentration of sugar in water • Concentration of maize starch in water • Concentration of wheat starch in water • Concentration of antifreeze in water...

Open the catalog to page 7
CoriolisMaster FCB100, FCH100 - 8

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J — … General data Enhanced Coriolis Control (ECC)function The Enhanced Coriolis Control (ECC)function has been specially developed for demanding applications, such as: • Liquids with gas phase • Liquids with rapidly changing densities • Fill operations with surge phases at the beginning or end • Liquids with high viscosity After the ECC function is activated, the device applies a particularly quick control algorithm to control the oscillating tubes in the device and therefore provide significantly better...

Open the catalog to page 8
CoriolisMaster FCB100, FCH100 - 9

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J Applications in accordance with API (American Petroleum Institute) For applications in accordance with API Chapter 5.6, the CoriolisMaster FCB100, FCH100 provides special parameters: • Calibration Pressure: Measuring medium pressure at which the device was calibrated at ABB. • Calibration Temp.: Measuring medium temperature at which the device was calibrated at ABB. • Pressure Level: Parameters for entry of the current operating pressure in the device by the user. • Flow Compens. factor: Display / output of...

Open the catalog to page 9
CoriolisMaster FCB100, FCH100 - 10

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J — Flowmeter sensor General installation conditions Installation location and assembly Note the following points when selecting the installation location and when mounting the sensor: • The ambient conditions (IP rating, ambient temperature range Tambient) of the device must be adhered to at the installation location. • Sensors and transmitters must not be exposed to direct sunlight. If necessary, provide a suitable means of sun protection on site. The limit values for ambient temperature Tambient must be...

Open the catalog to page 10
CoriolisMaster FCB100, FCH100 - 11

CORIOLISMASTER FCB100, FCH100 CORIOLIS MASS FLOWMETER | DS/FCB100/FCH100-EN REV. J Liquid measuring media Observe the following points to avoid measuring errors: • The meter tubes must always be completely filled with the measuring medium. • The gases dissolved in the measuring medium must not leak out. To safeguard this, a minimum back pressure of 0.2 bar (2.9 psi) is recommended. • The minimum vapor pressure of the measuring medium must be maintained when there is negative pressure in the meter tube or when liquids are gently simmering. • During operation, there must be no phase...

Open the catalog to page 11

All ABB Measurement & Analytics catalogs and technical brochures

  1. ProKiln GAC400

    24 Pages

  2. AV1 and AV2

    24 Pages

  3. SCK

    20 Pages

  4. INDI-BOY DSP

    8 Pages

  5. 9QGPS4500

    8 Pages

  6. 9QGPS3100P

    12 Pages

  7. 9QGPS2960

    12 Pages

  8. 9QGPS2625

    8 Pages

  9. MB3600-HP10

    5 Pages

  10. MB3600-CH10

    8 Pages

  11. ACF5000

    16 Pages

  12. Magnos28

    10 Pages

  13. EL3060

    8 Pages

  14. HP30

    4 Pages

  15. Aztec ATS430

    12 Pages

  16. LMS200

    12 Pages

  17. PGC5000

    8 Pages

  18. MR Series

    2 Pages