Overview: This document is a technical data sheet for ABB's 261GC, 261GG, 261GN, and 261AC gauge and absolute transmitters with direct mount seal, designed for industrial applications such as oil and gas, paper, chemicals, food, and pharmaceuticals.
Specifications:
  • Base Accuracy: ±0.1%
  • Span Limits: 0.3 to 60000 kPa; 1.2 in H2O up to 8700 psi; 0.3 to 10000 kPa abs; 2.25 mmHg up to 1450 psia
  • Turn Down Ratio: Up to 20:1
  • Housing: Stainless steel, optimized for harsh conditions
  • Compliance: PED compliance to SEP, RoHS II Directive 2011/65/UE
Functional Specifications:
  • Measuring Range: Various sensor codes with specific upper and lower limits
  • Damping: Configurable time constant between 0 and 60 seconds
  • Warm-up Time: Less than 10 seconds
  • Insulation Resistance: >100 MΩ at 500 V DC
Environmental Limits:
  • Temperature: Operating range -40 to 85°C; Storage range -50 to 85°C
  • Humidity: Up to 75% during storage
  • Vibration and Shock Resistance: Up to 2 g at 1000 Hz; 50 g shock resistance
Electrical Data:
  • Output: 4 to 20 mA with HART communication
  • Power Supply: 11 to 42 V DC, with intrinsic safety requirements
  • Load Limitations: Minimum resistance of 250 Ω for HART communication
Compliance and Safety:
  • ATEX and IECEx: Intrinsic safety and dust ignition protection
  • Factory Mutual (FM) and CSA: Intrinsic safety and non-incendive protection
Materials:
  • Diaphragms and Process Connections: Various materials available
  • Filling Fluids: Silicone oil, inert filling, white oil (FDA approved)
  • Housing: Stainless steel
Procedures: The transmitters are configured with HART communication and a 4 to 20 mA output. Parameters such as zero position, measuring range upper limit, output linearity, damping, and failure mode can be adjusted using an optional LCD indicator, a HART handheld communicator, or a PC with configuration software.
Norms and Standards: The document references standards for process connections, including ASME and EN 1092 forms, and specifies materials for diaphragms and fill fluids.
Recommendations: Use the optional LCD display for ease of configuration and ensure proper grounding with external ground terminals. Select appropriate process connections and materials based on application requirements.
Electrical Connections: Options include M16 x 1.5 tap hole, M20 x 1.5 via adapter, 1/2 in. - 14 NPT via adapter, Harting Han plug connector, and miniature plug connector. The HART version includes two connections for signal/auxiliary power and optional grounding terminals.
Mounting Dimensions: Detailed mounting dimensions are provided for various configurations, including standard design, flush diaphragm remote seal, and extended diaphragm remote seal, with diagrams and measurements in both metric and imperial units.
Accuracy Information: Accuracy is affected by temperature changes, with specific values provided for different process connections. Recommended measuring spans are listed for various configurations.
Ordering Information: Detailed ordering information specifies characters for base model, sensor span limits, diaphragm material, flange rating, and other options, providing a comprehensive guide for selecting the appropriate transmitter configuration.
Certifications: Various certificates are available, including 3.1 calibration, cleanliness stage, helium leakage test, pressure test, and SIL2 declaration of conformity, ensuring compliance with international standards and customer requirements.
Notes and Limitations: Notes clarify compatibility and restrictions, such as suitability for oxygen applications and limitations with certain materials and configurations.
Standard Delivery: The standard delivery scope includes general-purpose applications without explosion protection, no display or mounting bracket, and operating instructions in English. Customers are responsible for selecting suitable parts and filling fluids for their specific process medium.
Contact Information: Contact details for ABB offices in the UK, USA, and Italy are provided for further inquiries and support.
See more

Catalog excerpts

261GC, 261GG, 261GN and 261AC-1

ABB MEASUREMENT & ANALY TICS | DATA SHEET 261GC, 261GG, 261GN and 261AC Gauge and Absolute transmitters with direct mount seal

 Open the catalog to page 1
261GC, 261GG, 261GN and 261AC-2

Measurement made easy Engineered solutions for all applications — Featuring remote seal with capillary tube Base accuracy • ± 0.1 % — Span limits • 0.3 to 60000 kPa; 1.2 in H2O up to 8700 psi • 0.3 to 10000 kPa abs; 2.25 mmHg up to 1450 psia — Proven sensor technology together with state-of-the-art digital technology • Large turn down ratio of up to 20:1 — Stainless steel housing • Optimized for use in harsh ambient conditions • Extremely robust — Flexible configuration options • Local configuration via setup button for upper and lower range values • Local configuration via buttons on LCD indicator...

 Open the catalog to page 2
261GC, 261GG, 261GN and 261AC-3

— General description For the transmitters 261Gx and 261Ax, process connections with flush diaphragms are available in a variety of designs and dimensions to meet the requirements of a wide range of sectors, including industries such as oil and gas, paper, chemicals, food and pharmaceuticals. Special filling fluids are available for applications with high temperatures. For hygienic applications or use in the food industry, select filling fluids that are classified by the US Food and Drug Administration (FDA) as safe for use with food. — Functional specification Measuring range limits and span...

 Open the catalog to page 3
261GC, 261GG, 261GN and 261AC-4

— Operating limits Pressure limits Filling fluids The maximum permissible pressure depends on the permissible sensor overload (refer to table "Measuring range limits and span limits") and the permissible working pressure for the process connection according to the order information. Filling fluids (applications) Silicone oil for vacuum applications White oil for vacuum applications Temperature limits °C (°F) Environment Model 261GC, 261AC Ambient temperature limits Operating temperature range Process temperature in °C at maximum ambient temperature 40 °C Silicone oil for vacuum applications White...

 Open the catalog to page 4
261GC, 261GG, 261GN and 261AC-5

ATEX transmitter with type of protection "intrinsic safety Ex ia/ib" in accordance with Directive 2014/34/UE Transmitter with 4 to 20 mA output signal and HART communication IECEx transmitter with the following types of protection: "intrinsic safety ia", "non sparking nA" and "dust ignition protection by enclosure tb" Transmitter with 4 to 20 mA output signal and HART communication Ex ia IIC T6 bzw. T4 Ga/Gb Ex ia IIIC T66°C bzw. T95°C Da/Db Ex nA IIC T6 bzw. T4 Gc Ex tb IIIC T66°C bzw. T95°C Db Permissible ambient temperature range according to temperature class: Ambient temperature Temperature...

 Open the catalog to page 5
261GC, 261GG, 261GN and 261AC-6

— ...Operating limits Factory Mutual (FM) Transmitter with 4 to 20 mA output signal and HART communication Intrinsic Safety Class I; II and III; Division 1; Groups A, B, C, D; E, F, G Class I; Zone 0; AEx ia Group IIC T6; T4 Class I, II, III, Division 2; Groups A, B, C, D, F, G NEMA type 4X (indoor and outdoor installation) Canadian Standards Association (CSA) Transmitter with 4 to 20 mA output signal and HART communication Intrinsic Safety Class I; II and III; Division 1; Groups A, B, C, D; E, F, G Class I; Zone 0; Group IIC T6; T4 Class I, II, III; Division 2; Groups A, B, C, D; F, G NEMA type...

 Open the catalog to page 6
261GC, 261GG, 261GN and 261AC-7

— Electrical data and options HART digital communication and 4 to 20 mA output Power supply The transmitter operates from 11 to 42 V DC with no load and is protected against reversed polarity (additional loads enable operation above 42 V DC). During use in Ex ia zones and in other intrinsically safe applications, the power supply must not exceed 30 V DC. Ripple Maximum permissible supply voltage ripple during communication: Complies with HART FSK “Physical Layer” specification rev. 8.1. Load limitations Total loop resistance at 4 to 20 mA and HART: R(kΩ) = Voltage sup ply − Minimum operating...

 Open the catalog to page 7
261GC, 261GG, 261GN and 261AC-8

— Measuring accuracy Reference conditions according to IEC 60770 • Ambient temperature TU = constant in the range 18 to 30 °C (64 ... 86 °F) • Relative humidity = constant in the range 30 to 80 % • Ambient pressure PU = constant in the range 950 to 1,060 mbar. • Measuring span based on zero position • Transmitter with ceramic or Hastelloy separation diaphragm • Filling fluid: Silicone oil • Supply voltage: 24 V DC • Load with HART: 250 Ω • Transmitter not grounded • Characteristic setting: linear, 4 to 20 mA. Unless otherwise stated, errors are specified as a % of the measuring span value. The...

 Open the catalog to page 8
261GC, 261GG, 261GN and 261AC-9

— Technical specification (Please refer to the order information to check the availability of different versions of the relevant model) Materials Separation diaphragms1 See order information Process connection1 See order information Filling fluid for process connection See order information Sensor filling fluid Silicone oil, inert filling (carbon fluoride), white oil (FDA) Optional extras LCD display Can be rotated in 90° increments into 4 positions Additional tag plates Code I1: AISI 316 ss wired-on plate with laser printed customized data (4 lines of 30 characters each). If no text is provided,...

 Open the catalog to page 9
261GC, 261GG, 261GN and 261AC-10

— Configuration Transmitter with HART communication and 4 to 20 mA Standard configuration Transmitters are set to the customer's specified span at the factory. The set range and measuring point number are provided on the name plate. If this data has not been specified, the transmitter will be delivered with the following configuration: Parameter Factory setting Zero position Measuring range upper limit (URL) Transmitter failure mode Any or all of the configurable parameters listed above including the upper and lower range values - can easily be changed using the optional LCD indicator, a HART...

 Open the catalog to page 10
261GC, 261GG, 261GN and 261AC-11

— Mounting dimensions (not design data) - dimensions in mm (inch) Standard design Space for removing cover required Housing cover Electrical connection (with cable gland) Pressure transmitter Filter for atmospheric compensation Grounding / equipotential bonding terminal (optional) M10281

 Open the catalog to page 11

All ABB Measurement & Analytics catalogs and technical brochures

  1. ProKiln GAC400

    24  Pages

  2. AV1 and AV2

    24  Pages

  3. SCK

    20  Pages

  4. INDI-BOY DSP

    8  Pages

  5. 9QGPS4500

    8  Pages

  6. 9QGPS3100P

    12  Pages

  7. 9QGPS2960

    12  Pages

  8. 9QGPS2625

    8  Pages

  9. MB3600-HP10

    5  Pages

  10. MB3600-CH10

    8  Pages

  11. ACF5000

    16  Pages

  12. Magnos28

    10  Pages

  13. EL3060

    8  Pages

  14. HP30

    4  Pages

  15. Aztec ATS430

    12  Pages

  16. LMS200

    12  Pages

  17. PGC5000

    8  Pages

  18. LGR-ICOS 927S

    4  Pages

  19. MR Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.