Catalog excerpts
Turbidity Sensor 4296 is a compact fully integrated sensor for measuring optical backscatter in water. It is designed to be used with SeaGuard or SmartGuard data logger using AiCaP CANbus or as stand-alone sensor using RS-232 Advantages: • • • • • • • Smart Sensor for easy integration with SeaGuard and SmartGuard Direct read out of engineering data, multipoint factory calibrated Enter site specific reference data to receive absolute values in mg/l Low power consumption Rugged and robust with low maintenance needs Output format AiCaP CANbus, RS-232 3 depth ranges available, 300, 3000 and 6000 meters Turbidity is the optical property of the water that causes light to be scattered by suspended particles. High particle concentration causes high turbidity. By establishing the relationship between turbidity and the local suspended matter this measurement can be used for assessing the concentration of suspended matter. The Turbidity Sensor 4296 measures the backscatter of infrared light. A high efficiency light emitting diode is used to transmit modulated light into the water. The backscattered light is picked up by a sensitive photodiode and this signal is then conditioned, linearized and converted to data in engineering unit (FTU). In addition to turbidity, the sensor also measures water t
Open the catalog to page 1Range: Technical 4296,4296R 4296A,4296RA Turbidity: 4296B,4296RB Range: 4296C,4296RC Scattering angle: Resolution: Aperture: Temperature: Wavelength: Range: Scattering angle: Resolution: Aperture: Accuracy: 0.1% of reading or 0.025 FTU ±3% of range. Multipoint calibrated for each range 880 nm Output Parameters: Turbidity, Temperature, Sampling interval: Output format: Raw data 4296, 4296A, 4296B, 4296C AiCaP CANbus and RS-232 Output Parameters: Supply voltage: Current drain: interval: Sampling Average: Supply voltage: Current Maximum: drain: Quiescent: Average: Maximum: Operating depth:...
Open the catalog to page 2All Aanderaa Data Instruments AS catalogs and technical brochures
-
5819
2 Pages
-
MOTUS Wave Sensor 5729
2 Pages
-
SEAGUARD® String system
4 Pages
-
Mipeg X
2 Pages
-
RCM Blue
2 Pages
-
SMARTGUARD
2 Pages
-
Temperature Sensor 4060
2 Pages
-
SEAGUARD® Platform
4 Pages
-
Rainfall Sensor 3864/3864H
2 Pages
-
Pressure Sensor 4117
2 Pages
-
Oxygen Optode 4835
2 Pages
-
Oxygen Optode 4831/4831F
2 Pages
-
Conductivity Sensor 4019
2 Pages
-
RCOM 4987, 4988, 4989
2 Pages
-
Water level sensor 3791/A
4 Pages
-
Turbidity sensor 4112
2 Pages
-
Temperature Sensors 4050
2 Pages
-
Pressure sensor 4017
2 Pages
-
Oxygen optodes 4330/4330F
2 Pages
-
Conductivity Sensors
2 Pages
-
Loadtronic 3E
2 Pages
-
Data Buoy DB 4700
4 Pages