MULTI-PARAMETER DIGITAL MASS FLOW METERS Multi-Parameter flow meters provide accurate data on three different fluid parameters: flow pressure temperature The flow rate can be displayed in volumetric flow or mass flow engineering units for standard or actual (temperature, pressure) conditions. Flow meters can be programmed locally by the four button keypad and LCD or remotely via RS-232/RS-485 interface. DFM flow meters support various functions including: flow totalizer, flow, temperature, pressure alarms, automatic zero adjustment, 2 relay outputs, 0-5 Vdc / 0-10 Vdc / 4-20 mA analog outputs for flow, pressure and temperature. DFM’s are offered either as Digital Mass Flow Meters, Model Numbers: DFM26, 36, & 46 or as a Digital Multi-Parameter Meters, Model Numbers, DFM27, 37 & 47. Model Numbers are displayed in Table 29. THERE ARE 3 VOLTAGE (POWER) OPTIONS: +15Vdc, 12Vdc, & 24Vdc. Interface All features of the flow meter can be accessed via the local four button keypad and LCD. The digital interface operates via RS485 (optional RS-232 is available) and provides access to applicable internal data including: flow, temperature, pressure reading, auto zero, totalizer and alarms settings, gas table, conversion factors and engineering units selection, dynamic response compensation and linearization table adjustment. The analog interface provides 0 to 5Vdc or 0 to 10Vdc or 4 to 20 mA outputs for flow, pressure and temperature (jumper selectable). Auto Zero Totalizer The total volume of the gas is calculated by integrating the actual gas flow rate with respect to time. Both keypad menu and digital interface commands are provided to: Set the totalizer to ZERO. Start the totalizer at a preset flow. Assign action at a preset total volume. start/stop totalizing the flow. Read totalizer. Totalizer conditions become true, when the totalizer reading and the “Stop at Total” volumes are equal. Flow Alarm High and Low gas flow ALARM limits can be preprogrammed via keypad or remotely via digital interface. ALARM conditions become true when the current flow reading is equal or higher/lower than corresponding values of high and low alarm levels. Alarm action can be assigned with preset delay interval (0-3600 seconds) to activate the contact closer (separate for High and Low alarm). WWW.AALBORG.COM - E-MAIL ౧ : INFO@AALBORG.COM - PHONE 845.770.3000 - TOLL FREE IN U.S.A. AND CANADA 1.800.866.3837 ORANGEBURG N.Y. U.S.A. The DFM supports automatic sensor zero offset adjustment which can be activated locally via the keypad or remotely via digital interface. The auto zero feature requires absolutely no flow through the meter during auto zero process. Provisions are made to either start,
Open the catalog to page 1
MULTI-PARAMETER DIGITAL MASS FLOW METERS Pressure Alarm High and Low gas pressure ALARM limits can be preprogrammed via the keypad or remotely via digital interface. Pressure alarm conditions become true when the current pressure reading is equal or higher than corresponding values of high pressure alarm settings or equal or lower than corresponding values of low pressure alarm settings. Alarm action can be assigned to activate the contact closer (separate for High and Low pressure alarm). Temperature Alarm High and Low gas temperature ALARM limits can be preprogrammed via the keypad or...
Open the catalog to page 2
MASS FLOW METERS MULTI-PARAMETER DIGITAL I I Engineering Units The measured gas flow and associated totalizer data are scaled directly in engineering units via the front panel keypad or digital interface. THE FOLLOWING UNITS OF MEASURE ARE SUPPORTED: %F.S., L/min, L/h, mL/min, mL/h, scuft/h, scuft/min, lb/h, lb/min, one user defined engineering unit. Multi-Gas Calibration The DFM is capable of storing primary calibration data for up to 10 gases. This feature allows the same DFM to be calibrated for multiple gases while maintaining the rated accuracy on each. Conversion Factors Conversion...
Open the catalog to page 3
MULTI-PARAMETER DIGITAL MASS FLOW METERS W/ll/mlow PRESSURE IPERATURE Design Features ■ Multi-Drop Capability of up to 255 units (for RS-485 option). ■ Stores calibration data for up to 10 different gases. ■ Supports 10 different engineering units including user defined. ■ Programmable 12 digits Totalizer indicates total gas volume. ■ Flow Alarm limits for high and low gas flow with relay output. ■ Pressure Alarm limits for high and low gas pressure with relay output. ■ Temperature Alarm limits for high & low gas temperature with relay output. ■ Four button keypad and large 128x64 graphical...
Open the catalog to page 4
MULTI-PARAMETER DIGITAL MASS FLOW METERS WWW.AALBORG.COM - E-MAIL ౧ : INFO@AALBORG.COM - PHONE 845.770.3000 - TOLL FREE IN U.S.A. AND CANADA 1.800.866.3837 ORANGEBURG N.Y. U.S.A. * FOR HIGH FLOW MASS FLOW METER
Open the catalog to page 5
TEMP & PRESSURE OUTPUT SIGNAL (A only 26, 36, 46) **DIGITAL INTERFACE EXAMPLE: DFM36S-VAL5-AA5 50 L/min [N2] 20 psig SPECIFY: Flow Range, Gas and Pressure. DFM36 stainless steel, Viton® seals, 1/4" compression fittings, LCD readout display, ±15 Vdc power, 0-5Vdc output signal, RS485 digital interface. WWW.AALBORG.COM - E-MAIL M : INFO@AALBORG.COM - PHONE S 845.770.3000 - TOLL FREE IN U.S.A. AND CANADA 1.800.866.3837 • ORANGEBURG N.Y. U.S.A. 69
Open the catalog to page 6All Aalborg Instruments catalogs and technical brochures
-
Valve catalog
16 Pages
-
SMV STEPPING MOTOR VALVES
2 Pages
-
DPC
6 Pages
-
Rotameter Catalog
74 Pages
-
Miniatur-Nadelventil VB
2 Pages
-
OPTICAL SENSOR SWITCH O
6 Pages
-
TECHNICAL INFORMATION
11 Pages
-
CALIBRATIONS
13 Pages
-
PTFE-PFA flow meters
2 Pages
-
S meter
3 Pages
-
T / Tx meter
5 Pages
-
P / Px meter
5 Pages
-
MASS FLOW CONTROLLERS GFC
5 Pages
-
DIGITAL MASS FLOW METER ZFM
6 Pages
-
SINGLE TUBE FLOW METERS
5 Pages
-
PWM Paddlewheel meter
1 Pages
-
Pump Catalog 2015
33 Pages
-
Kits
1 Pages
-
In line ptfe flow meter
3 Pages
-
SDPROC
4 Pages
-
PSV-PSVD
5 Pages
-
DFM
6 Pages
-
DFC
8 Pages
-
XFM
6 Pages
-
GFM
5 Pages
-
VX
21 Pages
-
PWE Paddle Wheel Meter
5 Pages
-
PWM Paddle Wheel Meter
1 Pages