Catalog excerpts
Fire Detection & Alarm Avertisseurs sonore et visuel Détecteur Communication Eclairage Equipement d’installation Contrôle commande Hazardous and Industrial Detection, Alarm and Communication Devices Beacons I Sounders I Combination I Manual call point Detection I Alarm Control Station I www.a2s-antec.com Innovative Safety Solutions
Open the catalog to page 1Visual signalling Explosion-proof Beacon BC150 > Certification ATEX II2G Exd II C T4-T6 (Zone 1, 2) > Advantages • Ingress protection:IP66/67 • UV and Corrosion Resistance • Type selection: LED or Xenon • Status type: Flash, Rotary, Steady > General specifications • Enclosure material: GRP • Lens cover material: tempered glass • Cable entry : 4 x M20,M25 > Options • Enclosure color : Red, Yellow, Blue, Black • Lens color : Red, Yellow, Blue, Green, Clear • Anti Static GRP • Lens Guard (stainless-steel) Weatherproof Beacon BC100 > Advantages • Ingress protection IP66/67 • Polycarbonate...
Open the catalog to page 3Visual signalling Indoor alarm beacon BC90 > Advantages • Ingress protection IP43 • High visibility indoor alarm > General specifications • Designed according to EN 54 standard (BS 5879) • Enclosure material : ABS or Polycarbonate • Xenon or LED • Bracket material : Aluminium • Cable entry : under 12mm > Options • Telephone Initiated function • Enclosure color : Red, Blue, Black, • Lens color : Red, Yellow, Blue, Green, Clear Signal Tower > Advantages • Ingress protection: IP53 • Vibration and Impact resistant • Safe bulb changes: without the use of tools • Modular system for audible and...
Open the catalog to page 4Audible signalling Explosion-proof Sounder SD150 > Certification • ATEX II2G Exd IIC T4 ~T6 (Zone 1, 2) > Advantages • Ingress protection IP66/67 • Up to 115 dB • UV and Corrosion Resistance > General specifications • Enclosure material : GRP • Bracket : Stainless Steel • Cable entry : 2x M20, M25 > Options • Housing color : Red, Blue, Black , Others • 63 tones selections including 4 free tones for customized or recorded Weatherproof Sounder SD100 > Advantages • Ingress protection IP66/67 • Up to 123 dB • Corrosion Resistance > General specifications • Enclosure material : Polycarbonate •...
Open the catalog to page 5Visual signalling White indoor sounder Sonos > Advantages • Ingress protection IP65 • Up 95 dB • Certified CE DPC and NF > General specifications • Material: choc resistant polycarbonate • ø97,5 x 194,1mm Bell UWS/FWS > Advantages • Very robust • - 20° to +50° • IP 54 • Loud bells 105 dB > General specifications • Housing material : Aluminium die cast, epoxy powder • Bell dome material : Steel , epoxy power coated • Cable entry 5-12mm > Options • Color : UWS : RAL 7000/7015- FWS : RAL 3000
Open the catalog to page 6Combined visual and audible signalling Ex-proof combined unit SB150 > Certification • ATEX II2G Exd IIC T4~T6 (Zone 1, 2) > Advantages • Ingress protection IP66/67 • Up to 115 dB • 63 tones selections including 4 free tones for customized or recorded • UV and Corrosion Resistance > General specifications • Enclosure material : GRP • Bracket and lens guard : Stainless Steel • Cable entry : 2 x M20, M25 > Options • Lens guard • Beacon : LED or Xenon Ex-proof combined unit SB150-X > Certification • ATEX II2G Exd IIC T4~T6 (Zone 1, 2) > Advantages • Ingress protection IP66/67 • Up to 115 dB •...
Open the catalog to page 7Alarm signalling Explosion-proof call point CP135 > Certification • ATEX II2G Exd IIB+H2 T4~T6 > Advantages • Zone 1, 2 • Protection IP66 > General specifications • Enclosure material : UV and Corrosion Resistance GRP • Cable entry : 2 x M20, M25 > Options • Enclosure colour : Red, Blue, Yellow, Black/Yellow stripes or Others • Beacon : LED or Xenon Ex-proof call point CP150 > Certification • ATEX II2G Exd IIC T4~T6 (Zone 1, 2) > Advantages • Ingress protection: IP66 • UV and Corrosion Resistance > General specifications • Enclosure material : GRP • Cable entry : 4 x M20, M25 > Options •...
Open the catalog to page 8Alarm signalling Manuel Call Point S3000 > Advantages • Reset wrench and test • Integrated alarm indicator > General specifications • Pre-broken glass • Utilisation : 1,5 A / 24 Vcc - 0,3 A / 48 Vcc. > Options • Protection cap Explosion-proof push-button PB135 > Advantages • Ingress protection: IP66 • UV and Corrosion Resistance > General specifications • Enclosure material : GRP • Cable entry : 2 x M20, M25 > Options • « FIRE » signal can be added • Enclosure colour : Red, Blue, Yellow, Black/Yellow stripes or Others
Open the catalog to page 9Fire & Gas detector Beam Detector with Laser Alignment F5000 > Advantages • Cost-effective • Allows for 2 detectors per System controller • Auto compensates for building movement and contamination • Saving Installation time > General specifications • Building movement and contamination compensation • Low level system controler • Logs the 50 most recent events per detector > Options • Each detector configurable from 8m to 100m Flame Detector > Certification • II 2G Exd IIB+H2 T6 > Advantages • Superior high speed flame detector without compromise to false alarm immunity • Highly sensitive ,...
Open the catalog to page 10Fire & Gas detector Heat Detector HD 125 > Certification • ATEX, IECEX • UL FM/Class 1 Group A B C D >Advantages • Economical, Durable, Versatile, Rugged and Repeatable • Protection IP66/67 > General specifications • Enclosure material : Stainless Steel or GRP • Cable entry : 2 x M20, M25 • Two types of fixed temperature sensors : UL, ULC and FM N > Options • Exd cable glands, exd plugs, tags & duty label as accessories and spare parts • Enclosure color : Red, Black , Natural Metal Gas detector RAS > Certification • ATEX IIG EEX-d IIC T6 > Advantages • Small size, low power consumption •...
Open the catalog to page 11All A2S Advanced Safety Solutions catalogs and technical brochures
-
BPG
40 Pages
-
A2S’s Company Profile
10 Pages
-
Series PSDC PRESSURE SENSOR
3 Pages
-
Lighting
35 Pages
-
Telephony & Communication
16 Pages
-
Automation
6 Pages
-
Installation & Control
15 Pages
-
Telecommunications
25 Pages