Group: 4B Group

4B IE-Node (Industrial Ethernet Node) - Remote Sensor Monitoring for PLC's & Automation Systems
1 /
8Pages
Catalog excerpts

( Industrial Ethernet Node ) Remote Sensor Monitoring for PLC’s & Automation Systems • Supports • Supports PROFINET, EtherNet/IP and Modbus TCP/IP protocols • Up • Up to 16 Total Sensor Inputs with Available Expansion Boards • Configurator • Configurator Software for Easy Network Set Up and Visual Overview of All Devices • Sensor • Sensor Interface for PLC’s & Automation Systems
Open the catalog to page 1
SENSOR FUSES SENSOR SELECTION SWITCHES POWER SUPPLY ( IF INSTALLED) SENSOR INPUTS POWER FUSES Configurable IP Address THE FLEX I NETWORK DIAGRAM HB (HEART BEAT) - GREEN LED POWER - RED LED POWER CONNECTIONS IE-NODE 1 8 Contact or NTC Temperature and 2 Pulse or Analog (4-20 mA) inputs Class II Division 1, Groups E, F, & G T130oC Tamb -20oC to 50oC R4 Class II Division 1, Groups E, F, & G T130oC Tamb -20oC to 50oC R4 Class II Division 1, Groups E, F, & G T130oC Tamb -20oC to 50oC R4 Class II Division 1, Groups E, F, & G T130oC Tamb -20oC to 50oC R4 Ethernet Cable 10 Analog (4-20 mA) Inputs...
Open the catalog to page 2
The Industrial Ethernet Node (IE-NODE) is a remote monitoring interface designed to provide sensor data to PLC’s or other automation and control systems. The IE-NODE is available in two versions, both with a total of 10 sensor inputs. Version 1 has 8 contact or NTC temperature inputs, and 2 pulse or 4-20 mA (current loop) inputs. Version 2 has 10 inputs for 4-20 mA (current loop) sensors. Both units can be expanded to 16 sensor inputs with the installation of optional expansion boards. The IE-NODE operates by reading its sensor inputs and sending processed data when requested by another...
Open the catalog to page 3
TYPICAL SENSOR LOCATIONS BUCKET ELEVATOR ENCLOSED BELT CONVEYOR
Open the catalog to page 4
Easy order kits for the most common monitoring system configurations are shown below. For additional kits and options visit: www.go4b.com BUCKET ELEVATOR KIT-ETH-BE1 Industrial Ethernet Node (ETH-NODE1V46CAI or ETH-NODE1V4CAI) Qty. 1 – Industrial Ethernet Node with 8 contact or NTC inputs and 2 pulse or 4-20 mA inputs 1 BELT CONVEYOR KIT-ETH-BC1 Industrial Ethernet Node (ETH-NODE1V46CAI or ETH-NODE1V4CAI) Qty. 1 – Industrial Ethernet Node with 8 contact or NTC inputs and 2 pulse or 4-20 mA inputs. Belt Speed - Milli-Speed (M300M1V4AI) Qty. 1 - one sensor located on either side of the boot...
Open the catalog to page 5
The IE-NODE network configurator software provides you with a visual view of all devices on the network. It allows for easy identification of each unit on the network, and allows you to change network settings as needed. Alternatively, the network settings can be configured through the IE-Node built-in web server. SYSTEM CONFIGURATION SETTINGS Add-on instructions are provided at no charge for Allen Bradley PLC’s, ControlLogix® and CompactLogix® allowing easily implemented control logic that supports the functionality of the IE-NODE. 4B also has sample code and a GDSML file for easy...
Open the catalog to page 6
BUILD YOUR OWN DISPLAY! Example of Graphical Display Drag and Drop Your Equipment! Receiving Leg User Defined Labels The IE-NODE has in-built network support for Hazardmon.com service connectivity. HazardMon is a secure cloud based hazard monitoring solution providing status notifications and data logging for bucket elevators and conveyors. Live system status, graphs and historical data can be viewed on any web-enabled device (smartphone, tablet PC, desktop or laptop computer). To review all of the available features, and to see how the system works for yourself register for a free demo...
Open the catalog to page 7
IE-NODE SPECIFICATIONS Supply Voltage Power Dissipation Sensor Supply 24 VDC @ 800 mA (Across Fuse 1 - Fuse 4) Power Terminals Signal Terminals PROFINET, EtherNet/IP and Modbus TCP/IP Fixing Centers Cable Entry 2 Holes - 1-1/8 in. (28 mm) Diameter - 3/4 in. Conduit (ETH-NODE1V46CAI or ETH-NODE2V46CAI) UKEx, ATEX, IECEx - Zone 21 (ETH-NODExV4CAI) UKEx, ATEX, IECEx - Zone 22 (ETH-NODExV46CAI) For more information and a quote for your monitoring application, contact 4B today! 4B Braime Components Headquarters Hunslet Road Leeds, LS10 1JZ, UK Tel: +44 (0) 113 246 1800 Email: 4b-uk@go4b.com 4B...
Open the catalog to page 8All 4B Braime Components catalogs and technical brochures
-
RG4 Rotary Level Sensor
6 Pages
-
4B ATEX Junction Boxes
1 Pages
-
Milli-Vib - Vibration Sensor
2 Pages
-
4B Cement Industry Solutions
8 Pages
-
4B VIBMIL vibration sensor
2 Pages
-
RG3 Rotary Level Sensor
7 Pages
-
4B elevator buckets
17 Pages
-
Elevator Bolts
5 Pages
-
4B Elevator Belting
11 Pages
-
EASIFIT Elevator Bolts
1 Pages
-
FANG Elevator Bolts
1 Pages
-
Reference 70 Elevator Bolts
2 Pages
-
Euro Bolt
1 Pages
-
4B Sugar Mill Chains
24 Pages
-
JUMBO CC-S Elevator Buckets
2 Pages
-
4B Rotech Encoder
2 Pages
-
4B Tacho
2 Pages
-
X400 Alarmswitch
2 Pages
Archived catalogs
-
4B Level Indicators
7 Pages
-
M100 Stopswitch
2 Pages
-
Slack Chain Detection
1 Pages
-
4B explosion vent panels
1 Pages
-
M300 Slipswitch
2 Pages