Product Information BRAIME PLANT WIDE MONITORING SYSTEM The T500 Elite - HOTBUS™ is a serial communications system designed to monitor up to 256 sensors for combined belt alignment, belt speed, continuous bearing temperature, pulley alignment, level and plug conditions on bucket elevators and conveyors. Having automatic machine shutdown capability and PLC / PC compatibility, this advanced microprocessor based system offers low cost installation, versatility and easy system expansion. Hazardmon cloud monitoring solution is also available for historic data analysis and preventative or predictive machine maintenance. HOTBUS™ SYSTEM KEY ADVANTAGES ► Monitor more than 20 machines (up to 64 communication nodes or 256 sensing points) communication BUS for easy and economic wiring ► Up to 1km communication BUS length ► Up to 2km communication BUS length with a repeater module ► Temperature, belt-alignment, blockage conditions and belt slip / speed monitoring capability ► In-built Hazardmon cloud monitoring connection capability HOTBUS™ SYSTEM CONTROLLERS The T500 Elite HOTBUS™ system is a serial communication network based (BUS) on RS485 for collecting hazard monitoring sensor information from dedicated nodes. The T500 acts as the master of this network and requests data from slave nodes. The T500 processes the nodes’ data and makes decisions on whether to raise specific alarms. There may be up to 64 nodes on a single network each having up to 4 sensing points. The T500 has a dedicated alarm relay which will energise for any alarm condition on the BUS. Relays for specific alarms may be assigned if R500’s are used. Each R500 has 16 addressable volt-free contact relays and up to 4 R500’s may be used on a single T500 HOTBUS™ network providing 64 addressable alarm relays. The T500 system is a self-contained system and will operate and make decisions based on the parameters that you program. However, the F500 (Fieldbus Interface) unit may be used to gain external access to the T500 so that the collected data may be displayed and/or used as part of a SCADA/PLC system allowing greater interaction and control capability. Detailed specification, wiring diagrams and installation/operating instructions available upon request. Please refer to instruction manual for correct installation. Information subject to change or correction.

Open the catalog to page 1
4B HotBus - Serial Network Bucket Elevator & Conveyor Monitoring - 2

Product Information T500 Elite -Main Controller Power supply Power consumption Communication BUS connections Dimensions (L x W x H) Weight Enclosure apertures Operating temperature range Certificates and approvals Protection R500 Elite - Relay Block Power supply Power consumption Communication BUS connections Output Relays Dimensions (L x W x H) Weight Enclosure apertures Operating temperature range Certificates and approvals Protection Please refer to instruction manual for correct installation. Detailed specification, wiring diagrams and installation/operating instructions available upon...

Open the catalog to page 2
4B HotBus - Serial Network Bucket Elevator & Conveyor Monitoring - 3

Product Information Certificates and ATEX and lECEx ATEX and lECEx Power supply Power consumption Communication BUS connections Fieldbus protocols (replace XXX by one of the codes on the right) Dimensions (L x W x H) Weight Enclosure apertures Operating temperature range ETH -MobusTCP MGW - Mobus RTU PGW - Profibus DGW - DeviceNet 246 x 188 x 102 mm 1.3kg 2 holes, 25 mm dia -15°C to +50°C F500 Elite - Fieldbus Protocol Gateway HOTBUS™ system currently supports two types of remote communication nodes. Both of them are supplied in an ATEX approved and IP65 rated plastic enclosure....

Open the catalog to page 3
4B HotBus - Serial Network Bucket Elevator & Conveyor Monitoring - 4

Product Information HOTBOXTN4-CAI Power supply Power consumption Communication BUS connections Number of inputs Sensor types supported Dimensions (L x W x H) Weight Enclosure apertures Operating temperature range Certificates and approvals Protection Communication BUS connections RS-485 2 Wire (HOTBUS™) Sensor types supported Dimensions (L x W x H) Weight Enclosure apertures Operating temperature range Certificates and approvals Protection (2 run signals + 2 speed inputs) Speed (NPN Output) 140 x 111 x 88 mm 0.7kg 4 holes, M25 -20°C to +50°C ATEXand IECEx Zone 21 IP66 Please refer to...

Open the catalog to page 4
4B HotBus - Serial Network Bucket Elevator & Conveyor Monitoring - 5

Product Information BRAIME HOTBUS™ NETWORK DIAGRAM Alarm Horn Download Sensor Names from PC Belt Alignment Bearing Temperatures R500 Relay Unit 16 Relays – Up to 4 Units Per Network (64 Relays Total) Belt Alignment Plug Switch Node 3 – TN4 HOTBUS™ System Expansion (Max. 64 Nodes / 256 Sensors) Normally Closed Contact Normally Open Contact Speed Switch Detailed specification, wiring diagrams and installation/operating instructions available upon request. Please refer to instruction manual for correct installation. Information subject to change or correction. January 2016