Feeder/Motor - Protection Relay  Vamp 40 - 1

Feeder/MotorProtection Relay VAMP 40 >

カタログの1ページ目を開く
Feeder/Motor - Protection Relay  Vamp 40 - 2

? Complete Protection Comprehensive selection of protection functionsfor distribution network overhead line feeders, cable feeders, motor feeders including large motors, capacitor banks and reactors. ? Comprehensive Measurements Wide range of measurement functions including phase and residual currents, residual or line or phase voltage, frequency, current unbalance, maximum demand, negative phase sequence current, active and reactive power and energy according to the primary connection. ? Power Quality Assessment Power quality assessment and analysis including supervision of harmonics up to...

カタログの2ページ目を開く
Feeder/Motor - Protection Relay  Vamp 40 - 4

Traditional protection relay systemsdo not provide fast enoughprotection in an arc-fault situations.The VAMP 40 protection relay withintegrated arc protection alsoprovide a cost efficient high-speedMV busbar protection. The motor start-up register stores the motor start-up values(start current, duration etc.) significantly facilitating the correct setting of the relay even if critical motor data are unavailable from the manufacturer. > As a regularfeature of theVAMP relays standard COMTRADE type disturbancerecording files canbe uploaded for subsequent evaluation of anynetwork eventrecorded....

カタログの4ページ目を開く
Feeder/Motor - Protection Relay  Vamp 40 - 6

Order Code DescriptionNote VAMP 40 Feeder / motor protection relay VAMP Ltd > VEA3CG Ethernet Interface Module > VPA3CG Profibus Interface Module VSE001 Fiber optic Interface Module VSE002 RS485 Interface Module VSE004 VAMP 40 RS-485 module VSE005-1 Ethernet and RS-485 module VX003-3 Programming Cable (VAMPSET) Cable length 3 m VX028-3 Interface cable to VPA3CG ( Profibus adaptor)Cable length 3 m VX030-3 Interface cable to VEA3CG (Ethernet adaptor) Cable length 3 m VX032-3 Rear panel programming cableCable length 3 m VYX256A Optional seal for IP54 VP40 Arc option VA1DA-6 Arc SensorCable...

カタログの6ページ目を開く
Feeder/Motor - Protection Relay  Vamp 40 - 7

Rated current In 5 A (configurable for CT secondaries 1 10 A) Dimensions (W x H x D)280 x 195 x 55 mm - Current measuring range0օ250 A- Thermal withstand20 A (continuously)100 A (for 10 s) 500 A (for 1 s)- Burden< 0.2 VA Degree of protection IP 54 Weight 3 kg (terminal, package and manual) > Rated current Ion 1/5 A- Current measuring range050 A / 10 A Emission EN 61000-6-4 / IEC 60255-26- Conducted EN55011 / IEC 60255-25 0.15 - 30 MHz - EmittedEN55011 / IEC 60255-25 30 - 1000 MHz Immunity EN 61000-6-2 / IEC 60255-26- Static discharge (ESD) EN 61000-4-2 class IV / IEC 60255-22-28 kV contact...

カタログの7ページ目を開く
Feeder/Motor - Protection Relay  Vamp 40 - 8

Vamp LtdP.O.Box 810 FI-65101 VAASA FinlandVisiting address:Vaasa Airport Park Yrittjnkatu 15 Vaasa, Finland Tel: +358 20 753 3200Fax: +358 20 753 3205 Email: vamp@vamp.fi http:// www.vamp.fi > We reserve the rights to product alterations without prior notice.Copyright 䤩 Vamp Ltd. All trademarks are the property of theirrespective holders. VB40.EN004 size="-2">

カタログの8ページ目を開く

Vampのすべてのカタログと技術パンフレット

  1. vamp 265

    2 ページ

  2. VAMP 11V

    16 ページ

  3. VAMP 1 1 F

    16 ページ

  4. VAMP 50 series

    20 ページ

  5. VAMP 96 and VAMP 260

    12 ページ

  6. VAMP 57

    16 ページ

  7. VAMP 259

    12 ページ

  8. VAMP 125

    1 ページ

  9. VAMP 120 & 121

    8 ページ

  10. VAMP 11V

    16 ページ

  11. VAMP 321

    12 ページ

  12. VAMP 59

    12 ページ

  13. VAMP 55

    190 ページ

  14. VAMP 120

    8 ページ

  15. VAMP 40

    24 ページ

  16. VAMP 50

    20 ページ

  17. VAMP 230

    16 ページ

  18. VAMP 210

    2 ページ

  19. VAMP 135

    8 ページ

カタログアーカイブ

  1. VAMP 221_2013

    16 ページ

  2. VAMP 221_2011

    16 ページ

  3. VAMP 96

    16 ページ

  4. ARC Protection

    20 ページ

  5. Customer

    28 ページ

  6. Selection table

    1 ページ