SONOCONTROL 15 - 1

Non-intrusive full/empty limit switch at pipes with smaller nominal diameters (DN8 ... DN50) Application examples: Low level control in chromatography plant systems (HPLC) Protection against dry running for ultrapure / deionized water supply Overflow indication at ultrafiltration systems Measuring principle Ultrasound through the pipe wall, detected is the complete filling with liquids in the sensor axis; no direct contact between sensor and liquids; no need for constructional changes mounting the sensor at the pipe Stainless steel 1.4301, PEEK PVDF-clamp, coupling medium Water and watery liquids, liquids of low viscosity; Less suitable for emulsions, dispersions, suspensions, liquids with a lot of bubbles or solids Steel, Stainless steel, plastics, glass, ceramics Without coating, galvanized, lacquering, plastic coating, and the like The sensor takes the characteristics of the pipe in the empty and in the filled condition (in this order), triggered by an operating magnet. Mounting at the pipe / dimensions Together with a coupling medium the sensor is mounted laterally at the pipe. The fastening element consists of two parts. Together with the coupling medium, the sensor forms a complex connection around the pipe. The sensor is available in 4 sizes, which correspond to the different outer pipe diameters. The pipe clamp is delivered in a customized version adapted to the outer pipe diameter (when ordering quote the exact diameter). The given dimension Lmax applies for the corresponding maximum possible pipe diameter. Size Outer pipe diameter Dimensions of the PVDF-fastening element Lmax x W x H Temperature range Storage temperature: -40 ... 85 °C Pipe temperature: -40 ... 140 °C Ambient temperature: -40 ... 80 °C (the acceptable pipe temperature and ambient temperature are interdependent) Time response / switching delay Full  empty: 0,5 s Empty  full: 0,5 s Technical Datas

カタログの1ページ目を開く
SONOCONTROL 15 - 2

Connection / power supply 4-pole M12 sensor connector (2 contacts connected) Direct current 12 - 40 V (non-Ex), 12 - 33 V (Ex) Ripple max. 5 % (peak value: min. 12 V, max. 40V (non-Ex), 33 V (Ex)) Output / switching display 2-wire system (4...20 mA concept) The switching status is represented by the current consumption of the sensor. There is no additional switching output. Current consumption: empty: 8 mA ± 2 % full: 16 mA ± 2 % error: approx. 22 mA failed teach-in: approx. 0,2 mA Display: 2 LED (operating state, switching status) Explosion protection II2G Ex ib IIC T6 Gb Scope of delivery...

カタログの2ページ目を開く

U-F-M b.v.のすべてのカタログと技術パンフレット

  1. U-F-M B.V.

    6 ページ

  2. KATflow 230

    15 ページ

  3. KATflow 150

    14 ページ

  4. KATflow 100

    12 ページ