Product Catalogue Transformers Chokes Power supplies Customized components leadership in transformation www.trafomodern.com
カタログの1ページ目を開くleadership in transformation Since 1945 trafomodern Transformatorengesellschaft m.b.H. located in Hornstein, Austria develops, manufactures, produces and sells transformers, chokes, power supplies and other inductive components. Additionally trafomodern offers services like for example calculations around all kind of inductive components or winding of products. trafomodern is an international mid-size enterprise (SME) with strong Austrian roots. trafomodern clients at home and abroad trust our products and competence and have turned us into the Austrian market leader for inductive...
カタログの3ページ目を開くSystem summary Transformers Single-phase Type Single-phase control transformers with preferred rated voltage (types on stock) Single-phase control transformers Single-phase control, isolating and safety transformers Single-phase control, isolating and safety transformers Single-phase control transformers (ATEX-tested) Single-phase matching transformers Single-phase autotransformers Single-phase multi-winding transformers Portable transformers for protective separation Single-phase transformers for usage in medical environment Transformers Three-phase Type DTI DTZ DT DTF D4TB, D4TF DTSP...
カタログの4ページ目を開くSystem summary Chokes Type Single-phase smoothing chokes Single-phase commutating chokes Three-phase commutating chokes Additional equipment Type Enclosures Protective steel sheet enclosure IP23 optional equipment Increased currents Static shield winding, Tropics resistant, Additional tapping Inrush current limiter Screw-less terminal, Additional windings, Special accessories Engineering data Description Material surcharge Standard Terms and Conditions of Delivery and Payment Trademarks General design Terms and definitions Engineering data
カタログの5ページ目を開くSingle-phase-control transformers with preferred rated voltages (types on stock) Designed and tested according · IEC/EN 61558-2-2 · VDE 0570-2-2 · UL 5085-2 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 · VDE 0113 / VDE 0100 part 410 Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection terminal (<63 A) · Frequency 50/60 Hz · ±5 % tapping on the primary side Technical data: see page 9. Typical applications · Control voltage circuits · Functional low voltage Rated output Short time rating Material surcharge –› page 60 Sample order...
カタログの6ページ目を開くSingle-phase control, isolating and safety transf. w/ preferred rated voltages (types on stock) Designed and tested according to · IEC/EN 61558-2-2 / 2-4 / 2-6 · VDE 0570-2-2 / 2-4 / 2-6 · UL 5085-2 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 · VDE 0113 / VDE 0100 part 410 Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection terminal (<63 A) · Frequency 50/60 Hz · ±5 % tapping on the primary side Technical data: see page 11. Typical applications · Control voltage circuits · Functional low voltage · Protective separation Rated...
カタログの7ページ目を開くSingle-phase control transformers Designed and tested according to · IEC/EN 61558-2-2 · VDE 0570-2-2 · UL 5085-2 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 · VDE 0113 / VDE 0100 part 410 Typical applications · Control voltage circuits · Functional low voltage Rated output Short time rating Rated input voltage Rated output voltage Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection terminal (<63 A) · Frequency 50/60 Hz · ±5 % tapping on the primary side Further equipment · Enclosure IP23 · Additional tapping · Additional...
カタログの8ページ目を開くSingle-phase control transformers STN Connection lugs Max. space requirement 3) For STN 0.03 … 0.2 earth connection downwards 1) 2) Total weight No-load losses Shortcircuit losses Shortcircuit voltage Efficiency factor Total weight No-load losses Shortcircuit losses Shortcircuit voltage Efficiency factor Connection lugs Max. space requirement
カタログの9ページ目を開くSingle-phase control, isolating and safety transformers Designed and tested according to · IEC/EN 61558-2-2 / 2-4 / 2-6 · VDE 0570-2-2 / 2-4 / 2-6 · UL 5085-2 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 · VDE 0113 / VDE 0100 part 410 Rated output Short time rating Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection terminal (<63 A) · Frequency 50/60 Hz · ±5 % tapping on the primary side Typical applications · Control voltage circuits · Functional low voltage · Safety low voltage · Protective separation Rated input voltage...
カタログの10ページ目を開くSingle-phase control, isolating and safety transformers STI Fig.1 Connection lugs 2) For type STI/STZ 0,06 - 0,16 earth connection downwards Total weight No-load losses Shortcircuit voltage Efficiency factor Values measured at room temperature
カタログの11ページ目を開くSingle-phase control, isolating and safety transformers Basic equipment · Separate windings · Insulation class B · Ambient temperature –25 to 40 °C · Connection terminal (<63 A) · Frequency 50/60 Hz · ±5 % tapping on the primary side Designed and tested according to · IEC/EN 61558-2-2 / 2-4 / 2-6 · VDE 0570-2-2 / 2-4 / 2-6 · UL 5085-2 · CSA 22.2 No. 66 For use according to · IEC/EN 60204-1 · VDE 0113 / VDE 0100 part 410 Typical applications · Control voltage circuits · Functional low voltage · Safety low voltage · Protective separation Rated output Short time rating Rated input voltage...