video corpo

HFM-200 Flow Meter / HFC-202 Flow Controller
1 / 4ページ

{{requestButtons}}

カタログの抜粋

HFM-200 Flow Meter / HFC-202 Flow Controller - 1

TELEDYNE HASTINGS INSTRUMENTS Everywhereyoulook™ HFM-200 Flow Meter HFC-202 Flow Controller GENERAL PURPOSE FLOW METERS AND FLOW CONTROLLERS • Input Power +/- 15 VDC or +24 VDC (specify when ordering) • Available Flow Ranges: 0 - 10 sccm up to 0 - 25 slm (N2 Equivalent) • NIST Traceable Calibration APPLICATIONS • Gas Blending • Environmental Monitoring • Thin Film Deposition • Leak Testing • Medical Research • Chromatography • R&D BENEFITS • Excellent Stability • Proven Reliability • Outstanding Zero Stability "O C o co The Teledyne Hastings Instruments (THI) Model HFM Mass Flowmeter and HFC Mass Flow Controller represent over 65 years of experience in designing and manufacturing reliable, high quality flow instruments. The HFM/HFC Series of flow instruments is based on a modular design. At the heart of each instrument is an insulated thermal transfer sensor which provides enhanced zero stability. The instrument's inherent linear response to flow changes and THI's long-proven reputation for quality, result in the finest flow meters and flow controllers available today. Instruments are normally calibrated with the appropriate standard calibration gas (nitrogen), then a gas conversion factor is used to adjust the output the intended gas. Special calibration for other gases, such as oxygen, helium and argon, are available upon special request. teledyne HASTINGS INSTRUMENTS A Teledyne Technologies Company

カタログの1ページ目を開く
HFM-200 Flow Meter / HFC-202 Flow Controller - 2

Options: Fittings -VCR® VCO® Swagelok® Seals -Kalrez® Neoprene Buna-N Output -0-5 VDC 4-20 mA Cleaned for Oxygen service EMC EN 61326-1 Accessories Power Supplies available with: Integral Flow Totalizer Alarm Set Points Interconnecting cables COMMON SPECIFICATIONS HFM-200/HFC-202 Accuracy 1 SPECIFICATIONS HFM-200 Power Requirements (±15 VDC) Power Requirements (+24 VDC) SPECIFICATIONS HFC-202 Power Requirements (±15 VDC) Power Requirements (+24 VDC) 1 See Product Manual for critical information on instrument accuracy and the use of GCFs (gas conversion factors). Stated accuracy is for...

カタログの2ページ目を開く
HFM-200 Flow Meter / HFC-202 Flow Controller - 3

±15 VOLT 24 VOLT (15 PINS) (g pins) FITTING TYPE ELBOW SWAG

カタログの3ページ目を開く
HFM-200 Flow Meter / HFC-202 Flow Controller - 4

Range Information Range _ Flow Units _ Upstream Pressure (min/max) _ Downs ream Pressure (min/max) _ Is downstream pressure dependent on flow resistance? Y/N ^ S*. TELEDYNE HASTINGS INSTRUMENTS A Teledyne Technologies Company Telephone: (757) 723-6531 World Wide Web: http://www.teledyne-hi.com E-mail: hastings_instruments@teledyne.com 804 Newcombe Ave. Hampton, VA 23669 Standard Temperature (OC) and pressure (760 Torr) assumed unless otherwise specified

カタログの4ページ目を開く

Teledyne Hastings Instrumentsのすべてのカタログと技術パンフレット

  1. Service Overview

    4 ページ

  2. VT & CVT Series

    7 ページ

  3. HFM-HFC

    13 ページ

  4. HFM-201/HFC-203

    7 ページ

  5. DAVC

    5 ページ

  6. HPM 4/5/6

    4 ページ

  7. DIGITAL 300 SERIES

    8 ページ

  8. Gauge Tubes

    10 ページ

  9. REFERENCE TUBES

    2 ページ

  10. DCVT & DVT

    6 ページ

  11. HFM-305 / HFC-307

    4 ページ

  12. HFM-200 LFE

    5 ページ

  13. HFM-301/305/306

    24 ページ

  14. HFM-200-LFE

    5 ページ

  15. Digital VT

    6 ページ

  16. HFM-306

    4 ページ

  17. HFM-305/HFC-307

    4 ページ

  18. HFM-301/HFC-303

    4 ページ

  19. HFM-300/HFC-302

    4 ページ

  20. HFM-210/HFC-212

    4 ページ

  21. HFM-200/HFC-202

    4 ページ

カタログアーカイブ

  1. NALL SERIES

    2 ページ

  2. PowerPod-400

    4 ページ

  3. THCD-400

    5 ページ

  4. THCD—100

    6 ページ

  5. THCD-100​

    6 ページ

  6. HPM-760S

    4 ページ

  7. Products

    6 ページ

  8. Flow Service Plan

    1 ページ

  9. IGE-3​000​

    2 ページ

  10. THCD -100

    6 ページ

  11. THPS-400

    4 ページ

  12. 760 Plus

    2 ページ