カタログの抜粋

EFFICIENT VENTILATION FOR DWELLINGS WITH HEAT RECOVERY UNITS
カタログの1ページ目を開く
MECHANICAL VENTILATION WITH HEAT RECOVERY IN DWELLINGS POLLUTANTS Allergens Mites Animals Pollen VOCs (volatile organic compounds) CO (carbon monoxide) Paints Glues Thinners Bleaches Ammonia Moisture Water vapour Odours Burned gases Hydrocarbons CO2 (carbon dioxide) Fine particles Smoke Tobacco Radon Gas 30% of the European population has allergies and is affected by poor air quality indoors. 50% of houses have pollutants, which mostly affect children due to their size and development, they inhale twice as much pollutants than an adult. 90% of our time is spent indoors which is where the...
カタログの2ページ目を開く
CONTROLLED MECHANICAL VENTILATION Controlled mechanical ventilation and purification systems filter outside air to retain pollen, fine particles and bacteria, while indoor air is exhausted to get rid of the CO2, moisture and volatile organic compounds (VOCs). According to the scientists, in poorly ventilated indoor spaces, the risk of transmission of diseases that are transmitted through the air may be up to 20 times greater than outdoors. RISK OF MOISTURE AND CONDENSATION In the past, houses leaked air due to their poor air tightness and therefore were not very energy efficient. In...
カタログの3ページ目を開く
EFFICIENT SOLUTIONS FOR DWELLINGS oirhome Efficient ventilation equipment tor dwellings with heat recovery unit. High efficiency in filtration and compact design, ideal for installation in false ceilings.
カタログの4ページ目を開く
CONTROLLED MECHANICAL VENTILATION COUNTERFLOW PLATE HEAT EXCHANGER HIGH EFFICIENCY AND LOW CONSUMPTION THERMAL AND NOISE INSULATION Compact design with a low profile (210 mm height AIRHOME 150) Interchangeable nozzles depending on the position of the equipment High efficiency filters F7 removable Remote control and IAQ probes (T, RH, CO2, TVOCs) built-in BY-PASS BUILT-IN Easy installation false ceiling or wall Compatible with Modbus RTU
カタログの5ページ目を開く
HEAT RECOVERY UNIT EXTRACTION SUPPLY The heat exchanger component in the recovery unit transfers heat from the exhaust air extraction circuit to the external clean air supply circuit. The greater the thermal efficiency of the exchanger, the less need there will be to supply additional air conditioning. Counterflow heat exchanger 85-90% thermal efficiency. With no leaks between air circuits. The exchangers can be of the sensible heat or enthalpy type. Sensible heat exchangers only recover the heat present in air, whereas the enthalpy exchanger also recovers moisture, which means that...
カタログの6ページ目を開く
IDEAL FOR PASSIVE HOUSES HEAT EXCHANGER ENERGY SAVINGS CONTROL OF AIRFLOW BY ZONES
カタログの7ページ目を開く
Double flow ventilation with heat recovery unit allows renewing the indoor air by extracting it from humid areas such as kitchens and baths. Unlike a simple ventilation system, outdoor air is treated and routed to the dry areas of the houses.
カタログの8ページ目を開く
DOUBLE FLOW SYSTEM WITH HEAT RECOVERY UNIT A double flow system ventilates and filters the air as well as eliminates pollutants, microbes, viruses and allergens. These solutions improve the quality of life and comfort of people living in homes. AIRHOME solutions recover the existing energy in dwellings to improve the level of comfort Three dry areas (living room and two bedrooms) and two humid areas (bath and kitchen). BENEFITS • Control the airflow by zones and with a low noise level Ensure an optimum quality air thanks to its filtering system Prevent energy loss Four dry areas (living...
カタログの9ページ目を開く
This type of dwelling with three dry areas (living room and two bedrooms) and two humid areas (bath and kitchen). SODECA recommends the following flows: ■ EXTRACTION: Kitchen: 60 m3/h Bath: 30 m3/h ■ SUPPLY: Master bedroom: 30 m3/h Bedroom: 15 m3/h Living room: 45 m3/h ITEM CODE PRODUCT NAME QUANTITY ITEM CODE PRODUCT NAME QUANTITY
カタログの10ページ目を開く
SODCCA DUAL FLOW CMV 3H/2B This type of dwelling with four dry areas (living room and three bedrooms) and three humid areas (two baths and kitchen). SODECA recommends the following flows: ■ EXTRACTION: Kitchen: 60 m3/h Bath: 30 m3/h Bath: 30 m3/h ■ SUPPLY: Master bedroom: 30 m3/h Bedroom: 15 m3/h Bedroom: 15 m3/h Living room: 60 m3/h ITEM CODE PRODUCT NAME QUANTITY ITEM CODE PRODUCT NAME QUANTITY
カタログの11ページ目を開く
MODEL DWELLING 4H/2B This type of dwelling with five dry areas (living room and four bedrooms) and three humid areas (two baths and kitchen). SODECA recommends the following flows: ■ EXTRACTION: Kitchen: 60 m3/h Bath: 30 m3/h Bath: 30 m3/h ■ SUPPLY: Master bedroom: 30 m3/h Bedroom: 15 m3/h Bedroom: 15 m3/h Bedroom: 15 m3/h Living room: 45 m3/h ITEM CODE PRODUCT NAME QUANTITY ITEM CODE PRODUCT NAME QUANTITY
カタログの12ページ目を開く
COMPATIBLE ACCESSORIES WITH THE DOUBLE FLOW SYSTEM
カタログの13ページ目を開く
COMPATIBLE ACCESSORIES WITH THE DOUBLE FLOW SYSTEM WITH HEAT RECOVERY UNIT ITEM CODE PRODUCT NAME
カタログの14ページ目を開く
OTHER ACCESSORIES:4. 6. 7. ITEM CODE PRODUCT NAME
カタログの15ページ目を開く
OTHER SOLUTIONS
カタログの16ページ目を開く
SIMPLE FLOW MULTI-NOZZLE UNITS EVM Compact, multi-nozzle extractfan with adjustable outlet and three speeds EVP Low profile extract unit, for installation in false ceilings, and extract from 3 different zones, in single-family homes or apartments HEAT RECOVERY UNITS REB Heat recovery units with EC Technology motor and built-in by-pass UNIREC High efficiency single zone heat recovery ventilators for domestic installations
カタログの17ページ目を開く
IN-LINE DUCT FANS SV Low noise, in-line duct extractor fans mounted inside an acoustic casing SV/FILTER Low noise in-line duct extractors with different stages of filtration NEOLINEO In-line fans for small ducts with removable covers and small size with long life ball bearings SVE/PLUS Low noise in-line duct extractor fans mounted inside a 40 mm phonoabsorbent acoustic insulated casing CL/PLUS/EC In-line extract fans for rectangular ducts with a 40 mm thick acoustic casing to reduce noise and EC Technology motor ROOF-MOUNTED EXTRACT FANS CTD Centrifugal roof mounted extract fans for...
カタログの18ページ目を開く
BATHROOM EXTRACT FANS EDMF Extra flat bathroom extractor fans with a modern appearance and design EDQUIET/S Low consumption household extractor fans with very low noise levels EDD Household extractor fans with a modern appearance and design COLLECTIVE EXTRACT FAN UNITS CJV/EW Extract fans with automatic operation, vertical air outlet, EC Technology motor and constant pressure control for homes
カタログの19ページ目を開くSODECAのすべてのカタログと技術パンフレット
-
CJPF CJPF/ATEX
12 ページ
-
SV/FILTER/EC SV/HEPA/EC
16 ページ
-
CO2 CONTROL KITS
16 ページ
-
CAP-CO2/EC
5 ページ
-
PF/EC PF PF/ATEX
44 ページ
-
HATCH/HP
12 ページ
-
AIR CURTAINS
26 ページ
-
EC TECHNOLOGY SOLUTIONS
184 ページ
-
FANS FOR OVENS
42 ページ
-
THT/WALL
8 ページ
-
THT/WALL-F
5 ページ
-
LOW PRESSURE FANS
28 ページ
-
INDUSTRIAL FANS
340 ページ
-
SOLUTIONS IN SMOKE EXHAUST
328 ページ