カタログの抜粋

Soft Start-up Valve Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply New C € crqhs) Power consumption: 0.35 W * At 12/24 V DC Current model: 1.8 W (80 % reduction) Improved flow rate characteristics: Up to 2.2 times Q[l/min (ANR)]: 2433 Energy saving No air flow when the main valve is switched.
カタログの1ページ目を開く
Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series ∗1 Improved flow rate characteristics : Up to 2.2 times Q[l/min (ANR)]: 2433 Fill time: Up to 50 % shorter ∗1 For high speed air supply Body size Current model High speed air supply Current model Current model Improved adjustability at low speed air supply Needle Valve Flow Rate Characteristics Air flow rate [l/min (ANR)] Current model 2 3 4 Number of needle rotations Smaller profile and less work hours due to integrated silencer Built-in silencer (Option) When the silencer is mounted afterward: Silencer part number (when mounted...
カタログの2ページ目を開く
Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series Variations Q ∗1 C [l/min (ANR)] [dm3/(s·bar)] Electrical entry • Bracket • Pressure gauge • Silencer (Built-in) ∗1 These values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa. ∗2 Only for the DC type. Pilot Valve Variations DIN terminal minal with connector nnector DIN terminal without connector ∗1 A DIN terminal conforming to EN-175301-803C (former DIN 43650C) Pressure gauge Manual Override Variations...
カタログの3ページ目を開く
Body size *1 The 110 V AC and 115 V AC are interchangeable. The 220 V AC and 230 V AC are interchangeable as well. The allowable voltage fluctuation is -15 % to +5 % of the rated voltage for the 115 V AC or 230 V AC. *2 Only for the DC type. *3 Type “Y” is a DIN terminal conforming to EN-175301-803C (former DIN 43650C). *4 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected. *5 Only for the NPT thread • Option: Select one each for a to c. • Option symbol: When more than one specification is required, indicate in alphabetical order. Example) AV2000-02BGS
カタログの4ページ目を開く
*1 These values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa. Number of needle rotations
カタログの5ページ目を開く
*1 Bracket: 1 pc., Mounting screw: 2 pcs. (3 pcs. for AV5000-A) *2 Element, Element O-ring, Element cover: 1 pc. for each *3 □ of the pressure gauge part number will indicate the connecting screw type. No indication is necessary for R; however, indicate N for NPT. Please contact SMC regarding the pressure gauge supply for psi unit specifications. Spacer with bracket *1 Except port size 06 Assembly Example © Spacer with bracket Products do not come assembled. They should be ordered separately and assembled by the customer. * The Simple Specials System deals with product unification. Please...
カタログの6ページ目を開く
Working conditions Pilot valve Pressure conditions Operation description Internal construction/Cylinder actuation circuit (Meter-out control) example Operation description of the soft start-up valve When the pilot valve © is energised or turned ON manually, the spool © is pushed down due to the pilot air and gets into contact with the valve ©, closing the flow passage to port 3 (R). At this time, force that pushes the valve © > force that pushes down the spool ©. Therefore, the flow passage from the valve © to port 2 (A) is still closed. Furthermore, the piston © is pushed down due to the...
カタログの7ページ目を開く
*1 See below for How to Order of the pilot valve. How to Order Pilot Valve Assembly *1 The 110 V AC and 115 V AC are interchangeable. The 220 V AC and 230 V AC are interchangeable as well. The allowable voltage fluctuation is -15 % to +5 % of the rated voltage for the 115 V AC or 230 V AC. *2 Only for the DC type. *3 Type “Y” is a DIN terminal conforming to EN-175301-803C (former DIN 43650C). *4 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected. 7
カタログの8ページ目を開く
Soft Start-up Valve Dimensions Grommet: AV२00-२-२G२२-२-A AV5000-A Flow adjustment needle at low speed air supply Approx. 300 mm (Lead wire length) Manual override Pressure gauge port size 1/8 Pressure gauge (Option) Ø 37.5 Built-in silencer (Option) Bracket (Option) [mm] Standard specifications Port size Width across flats 22 Width across flats 24 Width across flats 30 Width across flats 36 [mm] Optional specifications With bracket With built-in silencer Width across flats 14 Width across flats 19 Width across flats 22
カタログの9ページ目を開く
AV2000-A/3000-A/4000-A/5000-A Series Dimensions DIN terminal: AV२00-२-२D/Y२२-२-A AV5000-A Flow adjustment needle at low speed air supply Pressure gauge port size 1/8 Pressure gauge (Option) Bracket (Option) Built-in silencer (Option) Manual override [mm] Standard specifications Port size Width across flats 22 Width across flats 24 Width across flats 30 Width across flats 36 [mm] Optional specifications With bracket With built-in silencer Width across flats 14 Width across flats 19 Width across flats 2
カタログの10ページ目を開く
AV2000-A/3000-A/4000-A/5000-A Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For F.R.L. precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: http://www.smc.eu 2. Holding pressure Since the valve might have slight internal leakage, it is not suitable for holding pressure in a tank or another vessel for a long period of time. 3. Not suitable for use as an emergency shutoff valve etc. The valves listed in this catalogue are not designed for...
カタログの11ページ目を開く
A V2000-A/3000-A/4000-A/5000-A Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For F.R.L. precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: http://www.smc.eu 1. To perform the initial speed adjustment of the outlet side actuator, supply air from this valve’s inlet side and turn ON the pilot valve. Then, rotate the needle counterclockwise from the fully closed position. 1. Preparation before piping Before piping is connected, it should be...
カタログの12ページ目を開くSMC のすべてのカタログと技術パンフレット
-
Serie HRR
64 ページ
-
Série VP/VG
33 ページ
-
Série XL
27 ページ
-
Série ACG/ARG/AWG
45 ページ
-
Série JXC5H/6H
36 ページ
-
LEJS100-X400 series
15 ページ
-
JMB series
13 ページ
-
JCM series
21 ページ
-
PF3A7*H
40 ページ
-
PF3W
34 ページ
-
Water Treatment
16 ページ
-
Digital Gap Checker
26 ページ
-
Vacuum Pad
16 ページ
-
One-touch Fittings
224 ページ
-
Electric Actuator
272 ページ
-
Rotary Actuator
40 ページ
-
Compact Guide Cylinder
18 ページ
-
Compact Slide
24 ページ
-
Air Cylinder
124 ページ
-
LEFB, LEFG-BS series
180 ページ
-
JMGP series
16 ページ
-
ISO Cylinder
32 ページ
-
IZD10
20 ページ
-
IZH10
8 ページ
-
Fan Type Lonizer
28 ページ
-
Check Valves
4 ページ
-
3 port solenoid Valve
74 ページ
-
Vacuum Ejector Series ZM
20 ページ
-
Series ZL
20 ページ
-
Series CM2
92 ページ
-
Series IDGA/IDG
56 ページ
-
IDH-A
12 ページ
-
CP96-C96-B
74 ページ
-
CVQ
24 ページ
-
HY
52 ページ
-
VNA
10 ページ
-
Series MXY
28 ページ
-
Series MXP
39 ページ
-
Air Slide Table
132 ページ
-
Compact Cylinder Series CQ2
138 ページ
-
S0700
112 ページ
-
SYJ
96 ページ
-
SY - NEW
164 ページ
-
VF
60 ページ
-
C(D)55 series
24 ページ
-
C(D)Q2 series
216 ページ
-
MGP series
36 ページ
-
11-LEFS series
19 ページ
-
LECS series
16 ページ
-
LECPA series
4 ページ
-
KQ series
80 ページ
-
IDF series
16 ページ
-
ZP series
69 ページ
-
MHF series
32 ページ
-
MHZ series
68 ページ
-
CRB series
44 ページ
-
MGJ series
7 ページ
-
AC series
98 ページ
-
VH series
14 ページ
-
LVA series
43 ページ
-
VDW series
28 ページ
-
LVM series
28 ページ
-
VX2 series
32 ページ
-
MXH series
32 ページ
-
MXF series
12 ページ
-
CXW series
48 ページ
-
CXS series
76 ページ
-
CQS series
40 ページ
-
CQM series
28 ページ
-
CLQ series
36 ページ