IDF series
1 / 12ページ

{{requestButtons}}

カタログの抜粋

IDF series - 1

Applicable for the high-temperature environments Ambient temperature : Max. 45°C Inlet air temperature : Max. 65°C (24% increase compared to the current model)

カタログの1ページ目を開く
IDF series - 2

Refrigerated Air Dryer IDF Series temperature environments New stainless steel heat exchanger helps reduce the load of the compressor

カタログの2ページ目を開く
IDF series - 3

Refrigerated Air Dryer IDF Series Series Variations Model Rated inlet condition Rated ambient temperature Port size Optional accessories Auto Drain Valve Longer life, Higher resistance to foreign matter Non-sliding part reduces the catching of foreign matter Shape prevents condensate accumulation Diaphragm type Poppet type Condensate and foreign matter are discharged completely. Easier maintenance One-touch mounting and removal of the bowl is possible without using any tools. Release the lock by sliding the lock button down while holding the body. Then, rotate the bowl guard and pull down...

カタログの3ページ目を開く
IDF series - 4

Refrigerated Air Dryer IDF Series Protect Pneumatic Equipment from Moisture! An air dryer removes the vapor from the moist compressed air delivered by the compressor and prevents it from causing the pneumatic equipment to fail. ¡ alfunctioning of valves and M actuators caused by dripping grease Effects of moisture on equipment ¡Generation of water droplets ¡ ecomposition of auto drain caused D by rusting inside pipes Main line filter Mist separator Control panel The malfunction of air bearings of 3D measurement device, etc. Washing machine

カタログの4ページ目を開く
IDF series - 5

Read the correction factors ® to © suitable to the operating conditions. *1 Values obtained from the table below Corrected air flow capacity = 6.0 m3/min (ANR) 1 (0.78 x 1.05 x 0.92 x 1.00) = 7.96 m3/min (ANR) The 60 Hz power supply frequency model with an air flow capacity which exceeds the corrected air flow capacity of 7.96 m3/min (ANR) is the IDF70. ^ Calculate the corrected air flow capacity. Obtain the corrected air flow capacity from the following formula. Corrected air flow capacity = Air flow rate 1 (Correction factor @ x ® x © x ©) ^ Select the model. Select the model with air...

カタログの5ページ目を開く
IDF series - 6

Replacement Parts Voltage Symbol Options Symbol * When multiple options are combined, indicate symbols in alphabetical order. Dustproof filter Auto Drain Replacement Part Nos. Element Dustproof Filter Replacement Part Nos. Description *1 A bowl O-ring is included. A One-touch fitting for connecting the drain tube is not included.

カタログの6ページ目を開く
IDF series - 7

Correction of Air Flow Capacity Refrigerated Air Dryer IDF Series Inlet air pressure [MPa] Outlet air pressure dew point [°C] MPa Model Specifications Calculation example: The air flow capacity when the dew point of the IDF60 is set to 10°C under the following conditions is calculated. [Operating conditions: Inlet air temperature: 35°C, Ambient temperature: 35°C, Inlet air pressure: 0.6 MPa, Power supply frequency: 50 Hz] 5.3 m3/min (ANR) x 1.00 x 0.94 x 0.92 = 4.6 m3/min (AnR) 1 The operating range does not guarantee use with normal air flow capacity. *2 ANR indicates the following set of...

カタログの7ページ目を開く
IDF series - 8

IDF Series Construction (Air/Refrigerant Circuit) Humid, hot air coming into the air dryer will be cooled Evaporation thermometer down by a cooler re-heater (heat exchanger). Water condensed at this time will be removed from the air by an auto drain and drained out automatically. Air separated from the water will be heated by a cooler reheater (heat exchanger) to obtain the dried air, which goes through to the outlet side. Cooler re-heater Ball valve Auto drain Capillary tube High pressure switch Volume control valve Pressure switch Drain outlet Accumulator Compressor for refrigeration...

カタログの8ページ目を開く
IDF series - 9

In addition to power supply connection, terminal blocks for operating, error, and remote operation signals are available. • The operating and error signals are no-voltage contact style. Operating signal...During operation: contact “close”, During stop: contact “open” Error signal.During error: contact “close”, During stop: contact “open” Contact capacity.Rated load voltage: 240 VAC or less/24 VDC or less Max. load current: 5 A (Resistance load)/2 A (Induction load) Min. applicable load: 20 VDC, 3 mA • Power supply voltage is applied to the remote operation contact. The external switch is to...

カタログの9ページ目を開く
IDF series - 10

IDF Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for Safety Instructions. For air preparation equipment precautions, refer to the Handling Precautions for SMC Products and the Operation Manual on the SMC website: http://www.smcworld.com |_Power Supply • Avoid locations where the air dryer will be in direct contact with wind or rain. (Avoid locations where relative humidity is 85% or more.) • Avoid locations where water, water vapor, salt water, or oil may splash on the product. • Avoid locations where dust or other...

カタログの10ページ目を開く
IDF series - 11

IDF Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to the back cover for Safety Instructions. For air preparation equipment precautions, refer to the Handling Precautions for SMC Products and the Operation Manual on the SMC website: http://www.smcworld.com Protection Circuit A Caution When the air dryer is operated in the following cases, the protection circuit will activate, the light will turn off and the air dryer will come to stop. • The compressed air temperature is too high. • The compressed air flow rate is too high. • The ambient...

カタログの11ページ目を開く
IDF series - 12

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1), and other safety regulations. Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or...

カタログの12ページ目を開く

SMC PNEUMATICのすべてのカタログと技術パンフレット

  1. Vacuum Unit 2024

    99 ページ

  2. AS-FS Series

    36 ページ

  3. MHL2 Series

    24 ページ

  4. JCM Serie

    18 ページ

  5. EX245 Series

    12 ページ

  6. SY

    268 ページ

  7. 5-p0966-0971-lmu

    5 ページ

  8. 5-p0948-0950-al800

    3 ページ

  9. es70-44c-vx2

    52 ページ

  10. es50-37-kq2

    124 ページ

  11. ex-pcw

    23 ページ

  12. 1-p2124-2152-ex510

    29 ページ

  13. 1-p2111-2122-ex500

    12 ページ

  14. 1-p2063-2073-ex260

    11 ページ

  15. 4-p0147-0178-msu-mds

    32 ページ

  16. es20-230b-crb2

    59 ページ

  17. 1-p1869-1878-vp3145

    10 ページ

  18. VP300/500/700 series

    42 ページ

  19. 1-p1789-1829-vqz100

    41 ページ

  20. 1-p1727-1788-syj300

    62 ページ

  21. VH

    9 ページ

  22. CUJ

    41 ページ

  23. AL

    3 ページ

  24. kj mm

    9 ページ

  25. AQ

    4 ページ

  26. SY3000/5000-X13

    2 ページ

  27. Series MB

    24 ページ

  28. Series LES

    23 ページ

  29. Series LEFB

    16 ページ

  30. Series PF3W

    28 ページ

  31. Series IDG?A/IDG

    56 ページ

  32. Floating Joint

    7 ページ

  33. Series IZS40/41/42

    32 ページ

  34. Series LEY

    7 ページ

  35. Series VHS

    12 ページ

  36. Series CY1S

    28 ページ

  37. SeriesCQ2/CQS/CQ

    4 ページ

  38. In-line Air Filter

    12 ページ

  39. Series CQ2/CQS

    2 ページ

  40. AS series

    2 ページ

  41. corporate guide

    13 ページ

  42. ZP

    69 ページ

  43. ZFA

    14 ページ

  44. ZA

    13 ページ

  45. MHF

    32 ページ

  46. MHZ

    68 ページ

  47. CRB

    44 ページ

  48. D

    117 ページ

  49. RB

    23 ページ

  50. CEP

    44 ページ

  51. RSK

    30 ページ

  52. CLK

    51 ページ

  53. MK

    20 ページ

  54. GLJ

    65 ページ

  55. MGJ

    7 ページ

  56. Mx

    36 ページ

  57. MXH

    18 ページ

  58. My3

    56 ページ

  59. my1b

    20 ページ

  60. CC

    15 ページ

  61. J

    14 ページ

  62. CQ2

    51 ページ

  63. standard cylinder

    84 ページ

  64. VFN

    6 ページ

  65. SY3000

    246 ページ

  66. SJ3A6

    18 ページ

  67. 1301/IW

    14 ページ

  68. CHQ/CHDQ

    19 ページ

  69. AC

    95 ページ

  70. HAW

    4 ページ

  71. HAA

    3 ページ

  72. ZB

    24 ページ

  73. CRB2

    35 ページ

  74. CJ1

    5 ページ

  75. SYJ

    62 ページ

  76. SJ

    78 ページ

カタログアーカイブ