カタログの抜粋

General-purpose connectors Push Pull connectors One-touch removal/mounting requires fewer work-hours *1 Abbreviation of the Automation Initiative of German (Deutschland) Automobile Manufacturers • PROFIenergy • Shared Device Power supply connector: 7/8 inch Compatible with new functions of • NET Load Class H • MRPD Push Pull connectors Digital input module Digital output module FW (firmware) update function Simultaneous writing is possible from network connection. Web server function Status check and valve ON/OFF are possible on the web browser. Existing model Compact, Lightweight Height: 40 mm reduction Weight: 53.5% reduction (@w465 g b Existing model: 1000 g
カタログの1ページ目を開く
Fieldbus System (For Input/Output) EX245 Series Compatible with PROFIenergy, the energy-saving function Generally, the switching off of the facilities in factories consumes a lot of time to restart them. PROFIenergy enables PROFINET communication to continue while saving energy by minimizing the time for restarting. When the commands for PROFIenergy energy-saving mode are sent from the I/O controller (PLC) to the I/O device (SI unit), the information of time for pausing is also sent (such as lunch breaks, nighttime, weekends, holidays). The SMC SI unit does not require time for restarting....
カタログの2ページ目を開く
Fieldbus System (For Input/Output) EX245 Series MRP/MRPD function MRP (Media Redundancy Protocol) function Even if a communication cable is disconnected or damaged at any location, communication can be continued. Furthermore, it is possible to identify the disconnection point, and the network disconnection time can be made within 200 ms. Normal flow of data Redundancy manager Data flow when the communication cable is disconnected Redundancy manager Client w Disconnected Client e * o use the MRP function, the PLC should be T able to support the MRP function. MRPD (Media Redundancy for...
カタログの3ページ目を開く
Fieldbus System (For Input/Output) EX245 Series Fast Start Up function For the Fast Start Up function, time from power ON to communication connection Save time when connecting and improve productivity In the case of a tool changer, it takes about 10 seconds for communication to be connected in some products after the power to the device installed on the tool is turned ON. For products which support the Fast Start Up function, communication can be operational even faster. * o use the Fast Start Up function, the PLC should be T able to support the Fast Start Up function. Fiber-optic cable...
カタログの4ページ目を開く
CONTENTS Fieldbus System (For Input/Output) EX245 Series
カタログの5ページ目を開く
Fieldbus System For Input/Output Connector type Digital Input Module EX245-DX1 EX245 -EA2- Digital input module specification Digital input (16 inputs) Digital Output Module EX245-DY1 Digital output module specification Digital output (8 outputs) Refer to the Web Catalog for manifold valve part numbers. Bracket 3 to 5 correspond to the mounting hole pitch of each manifold valve.
カタログの6ページ目を開く
Fieldbus System For Input/Output EX24o Series Common Specifications for All Units/Modules *1 The configuration file can be downloaded from the SMC website, https://www.smcworld.com Digital Input Module *1 An M12 (4-pin) connector can also be connected. Digital Output Module *1 An M12 (4-pin) connector can also be connected.
カタログの7ページ目を開く
EX245 Series Dimensions/Parts Description SI Unit EX245-SPN1A/2A PROFINET connection port M12 connector (4-pin, Socket, D-coded) Power supply connector 7/8 inch connector (5-pin, Socket) PROFINET connection port Push Pull connector EX245-SPN1A: SCRJ EX245-SPN2A: RJ45 Product label Power supply connector Push Pull connector (24 V) Digital Input Module EX245-DX1 Power supply connector 7/8 inch connector (5-pin, Plug) Digital Output Module EX245-DY1 Input connector 8 x M12 connector (5-pin, Socket) Output connector 4 x M12 connector (5-pin, Socket) LED indicator (ON/OFF of the output device)...
カタログの8ページ目を開く
EX245 Series Assembly Examples Manifold valve SI unit Digital input module Digital output module End plate Refer to the Web Catalog for order numbers. EX245-SPN1A EX245-DX1 EX245-DY1 EX245-EA2-3 The modules and manifold valve are not assembled at the time of shipment. After assembling the SI unit and manifold valve, assemble the modules. Width across flats: 2.5 mm∗1 Tightening torque JSY : 0.75 to 0.85 N·m SY : 0.75 to 0.85 N·m VQC : 0.5 to 0.7 N·m Manifold valve Manifold valve SI unit Digital input module Digital output module End plate (With bracket) *1 Tightening tool is not...
カタログの10ページ目を開く
t Communication cable/connector y Field-wireable communication connector u I/O cable with connector, I/O connector q Seal cap q Seal cap w Marker r 7/8 inch connector and related parts Be sure to mount a seal cap on any unused I/O connectors. Otherwise, the specified enclosure cannot be maintained. The signal name of I/O device and each module name can be entered and mounted on each module. For power supply connectors (10 pcs.) Seal cap for communication connector and power supply connector are included when EX245-SPN1A/2A is shipped (2 caps for each unit). r 7/8 Inch Connector and Related...
カタログの11ページ目を開く
t Communication Cable/Connector EX9-AC 005 EN-PSPS (With connector on both sides (Plug/Plug)) Terminal Core wire no. color Plug connector pin arrangement Metal part^^Shield Yellow White Orange Blue Metal parts Connections (Straight cable) Signal name TD+ RD+ TD-RD-Plug connector pin arrangement D-coded EN-PAPA (With angled connector on both sides (Plug/Plug)) Metal parts M12 SPEEDCON Plug connector pin arrangement D-coded sMetalparts Shield Metal parts Connections (Straight cable) Plug connector pin arrangement D-coded
カタログの12ページ目を開く
Terminal Signal name no. Terminal Core wire no. color Plug connector pin arrangement D-coded Green Metal parts Connections (Straight cable) Plug connector pin arrangement 0 Field-wireable Communication Connector PCA-1446553 D-coded Applicable Cable * The table above shows the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire.
カタログの13ページ目を開くSMC PNEUMATICのすべてのカタログと技術パンフレット
-
Vacuum Unit 2024
99 ページ
-
Air Cylinder CJ2 Series
117 ページ
-
AS-FS Series
36 ページ
-
IDF series
12 ページ
-
MHL2 Series
24 ページ
-
JCM Serie
18 ページ
-
EX245 Series
12 ページ
-
5 Port Solenoid Valve VQ
79 ページ
-
SY
268 ページ
-
5-p0979-0980-hep500
2 ページ
-
5-p0977-0978-aep100
2 ページ
-
5-p0966-0971-lmu
5 ページ
-
5-p0960-0966-alb900
6 ページ
-
5-p0956-0960-ald600
5 ページ
-
5-p0948-0950-al800
3 ページ
-
es70-44c-vx2
52 ページ
-
es50-37-kq2
124 ページ
-
ex-pcw
23 ページ
-
1-p2124-2152-ex510
29 ページ
-
1-p2111-2122-ex500
12 ページ
-
1-p2063-2073-ex260
11 ページ
-
4-p0147-0178-msu-mds
32 ページ
-
es20-230b-crb2
59 ページ
-
1-p1869-1878-vp3145
10 ページ
-
VP300/500/700 series
42 ページ
-
1-p1789-1829-vqz100
41 ページ
-
1-p1727-1788-syj300
62 ページ
-
5 Port Solenoid Valve S0700
111 ページ
-
5 Port Solenoid Valve VF
59 ページ
-
5 Port Solenoid Valve SV
127 ページ
-
VH
9 ページ
-
CUJ
41 ページ
-
AL
3 ページ
-
kj mm
9 ページ
-
AQ
4 ページ
-
SY3000/5000-X13
2 ページ
-
Series MB
24 ページ
-
Series LES
23 ページ
-
Series LEFB
16 ページ
-
Series PF3W
28 ページ
-
Series IDG?A/IDG
56 ページ
-
Floating Joint
7 ページ
-
Series IZS40/41/42
32 ページ
-
Series LEY
7 ページ
-
Series VHS
12 ページ
-
Series CY1S
28 ページ
-
SeriesCQ2/CQS/CQ
4 ページ
-
In-line Air Filter
12 ページ
-
5 Port Solenoid Valve
60 ページ
-
Series CQ2/CQS
2 ページ
-
AS series
2 ページ
-
corporate guide
13 ページ
-
ZP
69 ページ
-
ZFA
14 ページ
-
ZA
13 ページ
-
MHF
32 ページ
-
MHZ
68 ページ
-
CRB
44 ページ
-
D
117 ページ
-
RB
23 ページ
-
CEP
44 ページ
-
RSK
30 ページ
-
CLK
51 ページ
-
MK
20 ページ
-
GLJ
65 ページ
-
MGJ
7 ページ
-
Mx
36 ページ
-
MXH
18 ページ
-
My3
56 ページ
-
my1b
20 ページ
-
CC
15 ページ
-
J
14 ページ
-
CQ2
51 ページ
-
standard cylinder
84 ページ
-
VFN
6 ページ
-
SY3000
246 ページ
-
SJ3A6
18 ページ
-
1301/IW
14 ページ
-
CHQ/CHDQ
19 ページ
-
AC
95 ページ
-
HAW
4 ページ
-
HAA
3 ページ
-
ZB
24 ページ
-
CRB2
35 ページ
-
CJ1
5 ページ
-
SYJ
62 ページ
-
SJ
78 ページ
カタログアーカイブ
-
SYJ300/500/700 Series
62 ページ
-
Vacuum Unit ZK2 Series
60 ページ