SIPROTEC 7SL86 Combined line differential and distance protection
1 / 2ページ

{{requestButtons}}

カタログの抜粋

SIPROTEC 7SL86 Combined line differential and distance protection - 1

Description The combined SIPROTEC 7SL86 line differential and distance protection has specifically been designed for the protection of lines. With its modular structure, flexibility and the powerful DIGSI 5 engineering tool, the SIPROTEC 7SL86 device offers future-oriented solutions for protection, control, automation, monitoring, and Power Quality - Basic. Main function Differential and distance protection Interoperability of SIPROTEC 4 and SIPROTEC 5 line protection devices Tripping 3-pole, minimum tripping time: 9 ms Inputs and out- 12 predefined standard variants with puts 4/4 or 8/8 current/voltage transformers, 5 to 31 binary inputs, 8 to 46 binary outputs Hardware flexibi- Flexibly adjustable I/O quantity structure lity within the scope of the SIPROTEC 5 modular system Housing width 1/3 x 19 inch to 2/1 x 19 inch Applications • Line protection for all voltage levels with 3-pole tripping • Phase-selective protection of overhead lines and cables with single-ended and multi-ended infeed of all lengths with up to 6 line ends • Also used in switchgear with breaker-and-a-half layout • Transformers and compensating coils in the protection zone • Detection of ground faults in isolated or arc-suppres-sion-coilground power systems in star, ring, or meshed arrangement • Serial protection communication with SIPROTEC 5 and SIPROTEC 4 devices over different distances and physical media, such as optical fiber, two-wire connections, and communication networks • Phasor Measurement Unit (PMU) • Detection and recording of power-quality data in the mediumvoltage and subordinate low-voltage power system Functions DIGSI 5 permits all functions to be configured and combined as required. • Minimum tripping time: 9 ms • Main protection function is differential protection with adaptive algorithm for maximum sensitivity and stability even with the most different transformer errors, current-transformer saturation and capacitive charging currents • Several distance-protection functions selectable as backup protection or secondary main protection: Clas sic, reactance method (RMD), impedance protection for transformers • Directional backup protection and various additional functions • Adaptive power-swing blocking, out-of-step protection • Detection of current-transformer saturation for fast tripping with high accurac

カタログの1ページ目を開く
SIPROTEC 7SL86 Combined line differential and distance protection - 2

• Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, transient ground fault, cos 0, sin 0, dir. detection of intermittent ground faults, harmonic detection, and admittance measurement Ground-fault detection using the pulse detection method Fault locator plus for accurate fault location with in-homogenous line sections and targeted automatic overhead-line section reclosing (AREC) Arc protection Automatic frequency relief for underfrequency load shedding, taking changed infeed conditions due to decentralized...

カタログの2ページ目を開く

SIEMENS Energy automation and smart gridのすべてのカタログと技術パンフレット

  1. 7SR5 Platform

    86 ページ

  2. Reyrolle 7SR54

    2 ページ

  3. Reyrolle 7SR51

    2 ページ

  4. SICAM Q100

    2 ページ

  5. SIPROTEC 7SA87

    2 ページ

  6. SIPROTEC 7SA86

    2 ページ

  7. SIPROTEC 7SA82

    2 ページ

  8. SICAM A8000 Series

    11 ページ

  9. Reyrolle 5 Platform

    52 ページ

  10. SIPROTEC Compact

    210 ページ

  11. Catalog SICAM CMIC

    8 ページ

  12. 7SC80 Brochure

    8 ページ