カタログの抜粋

SICAM Power Quality and Measurement Catalog ⋅ Edition 6 siemens.com/powerquality
カタログの1ページ目を開く
2 SICAM Power Quality and Measurement ⋅ Catalog ⋅ Edition 6.
カタログの2ページ目を開く
SICAM T is a digital measurement transducer that allows the measuring of electrical quantities in electrical networks in a single unit. In industries, power plants and substations, transducers are especially used for measurand (for example current, voltage, power, phase angle, energy, or frequency) assignment into further processing through analog outputs or communication interface for precise control, notification or visualization tasks. Device Type Features • Design: compact and robust for flexible application in industrial and utility environments • Connections in 1-phase systems, in...
カタログの4ページ目を開く
Digital Measuring Transducer SICAM T – Field of Application and Utilization Application Example Using the analog and binary outputs for local monitoring and control purposes, including the integration of the measure- ments into higher-order systems (such as SCADA) via the existing communication interfaces, serial or via Ethernet (see Figure 4.1/2; Table 4.1/1). [dw_SICAM T Application, 1, en_US] Figure 4.1/2 Fields of Application for SICAM T SICAM ⋅ Power Quality and Measurement ⋅ Katalog ⋅ Edition 6.
カタログの5ページ目を開く
Voltage Current Power Frequency Phase Angle Energy Message Internal Cost Allocation Table 4.1/1 Application and Selection Fields The device is equipped with an Ethernet interface and, if installed in accordance with the device version, an RS485 interface to communicate with the control and protection system and with other automation systems. Device parameterization, transfer of measured data, counts and messages, and time synchronization with NTP are supported via Ethernet. The communication protocols are HTTP, 61850 (7KG9662) and Modbus TCP. The optional RS485 interface permits measured...
カタログの6ページ目を開く
Measurand Measuring 1-Phase 3-Wire Network (Delta) 4-Wire Network (Star) Circuit System Same Load (1I) Any Load (3I) Any Load (2I) Same Load (1I) Any Load (3I) Table 4.1/2 Measurands Corresponding to the Connection Type Power Values in Networks Measurands The following measurands can be captured or calculated: • RMS value for alternating voltage and alternating current • Active, reactive, and apparent power • Active, reactive, and apparent energy • Power frequency • Phase angle • Power factor and active power factor • Voltage and current unbalance - Mean value of the 3-phase voltage: Vsum -...
カタログの8ページ目を開く
Digital Measuring Transducer SICAM T – Graphical User Interface Graphical User Interface Device parameterization and monitoring software The unit is configured exclusively via a connected PC or laptop computer. The GUI user interface (GUI = Graphical User Interface) is integrated in the device. This means that additional software is not required for operating and parametering the device. Navigation is performed in Microsoft Internet Explorer via the icons in the toolbar. The user interface permits device state, communication, parameterization, log files, measured values, and maintenance...
カタログの9ページ目を開く
Digital Measuring Transducer SICAM T – Graphical User Interface Analog Outputs (AO) The following features are used for transferring measured values at DC analog outputs: linear, zoom, live-zero, knee-point, knee-point zoom, bipolar linear, bipolar knee-point zoom, square transfer characteristic curve. Figure 4.1/8 Input/Output Window Analog Outputs (AO) 116 SICAM ⋅ Power Quality and Measurement ⋅ Katalog ⋅ Editio
カタログの10ページ目を開く
[Appl-1,1, en_US] Figure 4.1/9 1-Phase System Connection Types The following connection types are supported: • 1-phase system • 3-wire network (same load) • 3-wire network (any load), 2 current inputs • 3-wire network (any load), 3 current inputs • 4-wire network (same load) • 4-wire network (any load) Connection Examples Figure 4.1/10 3-Wire Network, 2 Voltage and 1 Current Transformers, Same Load* Figure 4.1/11 3-Wire Network, 2 Voltage and 3 Current Transformers, Any Load* Figure 4.1/12 4-Wire Network, 1 Voltage and 1 Current Transformer, Same Load Figure 4.1/13 4-Wire Network, No...
カタログの11ページ目を開く
Supply Voltage Direct Voltage Rated input voltage Power consumption per input at Vrated 400 V Inputs for AC Current Measurements (Terminal Block E) Alternating Voltage Rated input voltage Inputs for Alternating Voltage Measurements (Terminal Block F) Rated input alternating voltages (can be parameterized) Binary Outputs (Terminal Block G) Maximum contact voltage DC Analog Outputs (Terminal Block K) Use as current outputs (direct current) 118 SICAM ■ Power Quality and Measurement ■ Katalog ■ Edition 6.0
カタログの12ページ目を開く
Serial Interface (Connection J) 111.3 [4 36) SICAM ■ Power Quality and Measurement ■ Katalog ■ Edition 6.0 119
カタログの13ページ目を開く
Description Variants Order No. Table 4.1/3 Selection and Ordering Data 120 SICAM ■ Power Quality and Measurement ■ Katalog ■ Edition 6.0
カタログの14ページ目を開く
CE conformity This product complies with the directive of the Council of the European Communities on harmonization of the laws of the Member States relating to electromagnetic compatibility (EMC Directive 2014/30/EU) and concerning electrical equipment for use within specified voltage limits (Low Voltage Directive 2014/35/EU). This conformity has been proved by tests performed according to the Council Directive in accordance with the generic standard EN 61000-6-5 (for EMC directive) and with the product standard EN 62586-1 (for Low Voltage Directive) by Siemens AG. The device is designed...
カタログの15ページ目を開く
Published Siemens AG 2017 Energy Management Division Digital Grid Automation Products Humboldtstr. 59 90459 Nuremberg, Germany www.siemens.com/powerquality For more information, please contact our Customer Support Center. Tel.: +49 180 524 7000 Fax: +49 180 524 2471 (Charges demending on provider) E-Mail: support.energy@siemens.com © 2017 Siemens. Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of...
カタログの16ページ目を開くSIEMENS Energy automation and smart gridのすべてのカタログと技術パンフレット
-
7SR5 Platform
86 ページ
-
Reyrolle 7SR54
2 ページ
-
Reyrolle 7SR51
2 ページ
-
SICAM Q100
2 ページ
-
7SR21 & 7SR22 Argus
2 ページ
-
SIPROTEC 7SA87
2 ページ
-
SIPROTEC 7SA86
2 ページ
-
SIPROTEC 7SA82
2 ページ
-
SICAM A8000 Series
11 ページ
-
SICAM Substation Automation
190 ページ
-
Reyrolle Product Catalogue
346 ページ
-
Reyrolle 5 Platform
52 ページ
-
SIPROTEC Compact
210 ページ
-
Catalog SICAM CMIC
8 ページ
-
7SC80 Brochure
8 ページ
-
Catalog - Bay Controller