Power entry modules without line filter https://www.schurter.com /PG05 IEC Appliance Inlet C14 or C18 with recessed Circuit Breaker TA45 See below: Approvals and Compliances Description - Panel mount : Screw-on version from front or rear side, snap-in version from front side - 2 Functions : Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole - Quick connect terminals 6.3 x 0.8 mm Characteristics - All single elements are already wired - Circuit Breaker non-illuminated or illuminated - Suitable for use in equipment according to IEC/UL 60950 Other versions on request - Unwired versions - Other rocker marking - Variant with notch for V-Lock mating Cordsets References Alternative: version with line filter DF12 Substitute for type 6145 Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor-Stock-Check, Accessories, Detailed request for product, Microsite Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC 10 A/250 VAC; 50 Hz Ratings UL/CSA15 A/250 VAC; 60 Hz Dielectric Strength > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) Allowable Operation Tempe- -10 °C to 55 °C rature IP-Protectionfrom front side IP 40 acc. to IEC 60529 Insulation cover Suitable for appliances with protection class I or II acc. to IEC 61140 TerminalQuick connect terminals 6.3 x 0.8 mm Panel Thickness S Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.5/2/2.5/3 mm Material: HousingThermoplastic, black, UL 94V-0 UL 60320-1, CSA C22.2 no. 60320-1 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or non-illuminated. Optional with undervoltage-or remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 2 3A/240VAC : 300A Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DF11 Approval Logo cTOus Certificates VDE Approvals UL Approvals Certification Body Description UL UL File Number: E96454 Connectors H.SCHURTER 1 ELECTRONIC COMPONENTS
カタログの1ページ目を開く
Power entry modules without line filter https://www.schurter.com /PG05 Product standards Product standards that are referenced Design Designed according to Designed according to Designed according to Standard Description IEC 60320-1 Appliance couplers for household and similar general purposes UL 60320-1 Standard for Attachment Plugs and Receptacles CSA C22.2 no. 60320-1 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Designed for applications...
カタログの2ページ目を開く
Power entry modules without line filter https://www.schurter.com /PG05 Snap-in version * --- Version TA45 with undervoltage release
カタログの3ページ目を開く
Power entry modules without line filter https://www.schurter.com /PG05 Table 1 Selection for type TA45 Order example • Circuit Breaker of Equipment • 2-pole, rocker actuated • Quick connect terminal Other types on request Diagram Thermal overload protection Without illumination With illumination Colours Switch front black black black white black – – – orange transp. Rocker legend Illustration white / weiss printed / bedruckt printed / bedruckt printed / bedruckt embossed / Relief Position of the rocker legend e.g F white / weiss black / schwarz Rated current circuit breaker of equipment In...
カタログの4ページ目を開く
Power entry modules without line filter https://www.schurter.com /PG05 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A Rated current Ambient temp. Rated current Ambient temp. Multiple of rated current Multiple of rated current Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been...
カタログの5ページ目を開く
Power entry modules without line filter https://www.schurter.com /PG05 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete Connector further types to DF11 Mating Outlets/Connectors shuttered Power Cord Overview complete VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS Power Cord further types to DF11 Connectors ELECTRONIC COMPONENTS The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be...
カタログの6ページ目を開くSCHURTER/シュルターのすべてのカタログと技術パンフレット
-
FMAD NEO
6 ページ
-
THS
5 ページ
-
TTS
4 ページ
-
Product News
4 ページ
-
FMAB NEO
12 ページ
-
FPG1
4 ページ
-
FMAB HV
6 ページ
-
UMT-W
4 ページ
-
OGN
3 ページ
-
0712
3 ページ
-
CPS
7 ページ
-
DG12
10 ページ
-
4751
4 ページ
-
FMAD CP
4 ページ
-
4783
4 ページ
-
EF11
8 ページ
-
PFRY
4 ページ
-
PFRA
6 ページ
-
PFMF
4 ページ
-
PFDF
3 ページ
-
Company Profile
20 ページ
-
Voltage Selector
1 ページ
-
Resettable Fuses
1 ページ
-
6051.2067
3 ページ
-
6051.2068
3 ページ
-
4797-5
4 ページ
-
6051.2063
3 ページ
-
6051.2061
3 ページ
-
6051.2015
3 ページ
-
3-108-993
2 ページ
-
3-100-361
3 ページ
-
GP21
3 ページ
-
FMER SOL
10 ページ
-
CMF2, CMF5
3 ページ
-
CDS1
5 ページ
-
DKIH-3
6 ページ
-
4710-5
5 ページ
-
Touchkit
3 ページ
-
USN 1206
3 ページ
-
FPBB RAIL
7 ページ
-
DD14
8 ページ
-
VAC19KS
3 ページ
-
UMK 250
4 ページ
-
TA35 Rocker 1Pole
6 ページ
-
4761
3 ページ
-
4732
4 ページ
-
FUS
3 ページ
-
DKIH
6 ページ
-
FSO
2 ページ
-
CSO
3 ページ
-
CMF1, CMF4
3 ページ
-
FMAC NEO
5 ページ
-
MSM DP 30
8 ページ
-
PSE AE 16
3 ページ
-
MSM LA CS 22
7 ページ
-
MSM LA CS 19
6 ページ
-
PSE AE 30
5 ページ
-
PSE EX 16
5 ページ
-
PSE EX 19
5 ページ
-
PSE NO 19
6 ページ
-
PSE NO 16
6 ページ
-
PSE EX 22
5 ページ
-
PSE NO 27
6 ページ
-
PSE NO 24
6 ページ
-
PSE NO 22
8 ページ
-
PSE IV 16
6 ページ
-
PSE HI 22
6 ページ
-
PSE NO 30
7 ページ
-
PSE M22 IV
7 ページ
-
MCS ES 18
3 ページ
-
MCS ES 22
3 ページ
-
6051.2094
3 ページ
-
6051.2093
3 ページ
-
6051.2078
3 ページ
-
6051.2077
3 ページ
-
6051.2070
3 ページ
-
6051.2072
3 ページ
-
6051.2071
3 ページ
-
6051.2037
2 ページ
-
6051.2030
3 ページ
-
6051.2032
3 ページ
-
6051.2031
3 ページ
-
6051.2027
3 ページ
-
3-107-570
2 ページ
-
3-107-569
2 ページ
-
VAC13KS
4 ページ
-
DD21
5 ページ
-
DD11
5 ページ
-
DG11
7 ページ
-
typ_6051.2016
3 ページ
-
typ_6051.2008
3 ページ
-
typ_6051.2009
3 ページ
-
typ_6051.2001
4 ページ
-
typ_6051.2007
3 ページ
-
typ_6051.2003
3 ページ
-
typ_6051.2004
3 ページ
-
typ_4762
3 ページ
-
typ_3-101-514
3 ページ
-
typ_3-101-501
3 ページ
-
typ_3-100-528
3 ページ
-
typ_3-100-734
3 ページ
-
typ_3-100-526
3 ページ
-
typ_3-100-523
3 ページ
-
typ_3-100-524
3 ページ
-
typ_3-100-527
3 ページ
-
typ_3-100-522
3 ページ
-
typ_3-100-356
3 ページ
-
typ_3-100-355
3 ページ
-
typ_3-100-354
3 ページ
-
SWA2
2 ページ
-
PB 1021
2 ページ
-
TM12-111
6 ページ
-
PTS
4 ページ
-
Piezo Keypads
4 ページ
-
PB 1011
2 ページ
-
FMAD CEE
3 ページ
カタログアーカイブ
-
2020 PFHT
3 ページ
-
Product News 2018
4 ページ
-
SCHURTER Company Profile
10 ページ
-
PFDF
3 ページ
-
2015 PFHT
3 ページ
-
PFUF
3 ページ
-
DKFP
5 ページ
-
FMAD RAIL
3 ページ
-
FMAC RAIL
3 ページ
-
FMBD NEO
6 ページ
-
FMAC SINE DCL
4 ページ
-
FMAC SINE
4 ページ
-
FMAB RAIL
3 ページ
-
FMBB NEO
11 ページ
-
FMBB RAIL
3 ページ
-
5120
10 ページ
-
SMD-FTT
1 ページ
-
OMZ 125
1 ページ
-
4840.2200
2 ページ
-
6051.5003
2 ページ
-
6000.0224
2 ページ
-
6051.2030
2 ページ
-
6051.2003
2 ページ
-
FLBB
2 ページ
-
4741
2 ページ
-
P685
2 ページ
-
KE
4 ページ
-
GSF2
4 ページ
-
GSF1
5 ページ
-
Felcom 64
4 ページ
-
6135
5 ページ
-
KG-Bowdencable
4 ページ
-
KD-Bowdencable
4 ページ
-
DC21
3 ページ
-
1074
4 ページ
-
DC11
5 ページ
-
CMF3, CMF6
2 ページ
-
PFNF
3 ページ
-
ESO 10.3x38
1 ページ
-
SHT 6.3x32
1 ページ
-
KEB2
1 ページ
-
New product: 6610
3 ページ
-
New product: UMZ 250
3 ページ
-
New product: CSO
2 ページ
-
New product: UMF 250
3 ページ
-
New product: UMT-H
3 ページ
-
TA35 Rocker 2Pol
8 ページ
-
SCHURTER range at a glance
236 ページ
-
ASO / FSO
8 ページ
-
Varistors
40 ページ
-
Flyer MGA-S
6 ページ