HVAC and pressurization IECEx and ATEX
カタログの1ページ目を開くHeating Ventilation & Air Conditioners Starting in the 1950s air conditioners have become standard features in residential and industrial applications. Although explosion protection started around 100 years ago, forced cooling in such an environment has always been a challenge. Demands as applicable in the oil and gas industry are quite different to a residential or standard industrial application. For many years now air conditioners form a standard ingredient for the comfort of people around the world. Especially in the oil and gas industry it is essential to have a controlled and safe...
カタログの2ページ目を開くSelecting your HVAC unit 9 HVAC Request Form 11
カタログの3ページ目を開くLIFTING LUGS (OPTIONAL) PURGE £ PRESS AUXILIARY BLOWER EVAPORATOR BLOWER ELECTRIC HEATER EVAPORATOR COIL DYPASS DAMPER Optional features • 304/316 stainless steel cabinet • Multiplexer: capable of control- ling many separate units conserving power) • Explosion protected crankcase heater • Purge & pressurization add-on back-up) can assist in purging • Copper fin/copper tube coils with highly corrosion resistance • Coil coatings: Esgard, TechniCoat, E-Coat, Heresite, and Thermoguard • Extra corrosion protection • Chemical filtration- Remotely mounted control system • Special and high...
カタログの4ページ目を開くRedundancy The cooling part of our HVAC has our unique standard redundancy design concept. Depending on the climatic data and type of application following redundancy features are possible. 10 kW Cooling capacity automatically includes a redundant design consisting of two independent 5kW air conditioning systems. If one system fails, the application can still run under most normal operational conditions. Dual redundancy design is available enabling 100% backup power. This is applicable for high load equipment cooling and demanding highest ambient temperatures. N+1 redundancy is also...
カタログの5ページ目を開くPurge & pressurization The InPac HVAC system can provide ATEX certified pressurization to a building or other suitable shelters. The used protection method is also based on the latest EN and IEC standard and suitable for Zone 1 or Zone 2. Figure 1. Typical use of Backup Blower for Purge/Pressurization. Under normal operation, one set of blowers is operating, taking air from the outside and circulating it through area. Figure 2. Typical use of Backup Blower for Purge/Pressurization. During purge, all blowers are active and the return air disengaged, which forces protective air into the area...
カタログの6ページ目を開くSafe atmosphere ChemPac add-on can be used where the control of gaseous contaminations may be a concern. The ChemPac is an optional feature for the InPac series and is available in multiple sizes to match customer requirements. The ChemPac typically combines four stages of filtration for removal of airborne pollutants and corrosive gases when combined with one of our air conditioning units. Along with pellet filtration media, we also offer adsorbent honeycomb media as a solution. The honeycomb modules provide increased rate of adsorption of gases and significantly lower pressure drop, a...
カタログの7ページ目を開くSolutions Electromach B.V. situated in The Netherlands, has more than 50 years experience in manufacturing explosion protected systems for hazardous areas. Our system solutions department is specialized in developing custom made skids and container-based solutions. Our organisation is all-round certified for designing ATEX and IECEx systems. We are supported by a 13.000 m² electrical and mechanical workshop including specialized container workshop. Our team is happy to support you in a 'ready for connection' solution enabling: Minimizing project costs Shortened turn around One stop shopping...
カタログの8ページ目を開くSelecting your HVAC unit #1 Required Cooling Load Required cooling load is determined by the size of the area to be conditioned including total interior volume, number of occupants, total heat contribution of all electrical equipment contained in the area, thermal isolation values of wall, floor, and ceiling insulation system, as well as the final geographical destination of the unit/building. Our trained staff will be happy to assist you in preparing a very detailed computerized load study calculation for your unique application. #2 Hazardous Location Depending on the types of hazardous...
カタログの9ページ目を開くCooling power (kW) Model selection Cooling power (kW) Model selection
カタログの10ページ目を開くHVAC Request Form Company name building description Building size insulation factor equipment heat load, sensible equipment heat load, latent lighting head load number of building personnel location of building avg. design temp. outside: db/wb avg. design temop. inside: dw/wb voltage Number of air changes building pressure requirement building sketch
カタログの11ページ目を開くE-mail: info@electromach.nl 9200 Dendermonde (Sint-Gillis), Belgium E-mail: info@stahl.be
カタログの12ページ目を開くR. STAHL AG/スタールのすべてのカタログと技術パンフレット
-
IS1+ The Remote I/O
16 ページ
-
NETWORK TECHNOLOGY
20 ページ
-
Actuators Series 8602/3
20 ページ
-
PRODUCT CATALOGUE 2019
909 ページ
-
electrical catalog 9016
236 ページ
-
CATALOGUE 2018
1094 ページ
-
LED floodlight 6125
2 ページ
-
ModibEx by R. STAHL
4 ページ
-
Ex-Poster
1 ページ
-
BROCHURE: LIGHTING
24 ページ
-
Signalling_Catalogue_S2_2014
148 ページ
-
Condensed Catalogue 2015
622 ページ
-
AK00_III
12 ページ
-
EN/IEC 61439
4 ページ
-
Seminare D-A-CH 2014
25 ページ
-
SERIES 200
8 ページ
-
HMI Oil and Gas
20 ページ
-
HMI Overview
36 ページ
-
SolConeX
12 ページ
-
GUBox
4 ページ
-
Pedant light fittings
16 ページ
-
Portable Lamp 6148
4 ページ
-
EXLUX 6001
4 ページ
-
Focus customer
24 ページ
-
AK00_III
5 ページ
-
BinaryOutput_Auto
5 ページ
-
9160601310_de_en
24 ページ
-
STAHL HMI Solutions
32 ページ
-
Lighting
16 ページ
-
Competence at a glance
24 ページ
-
Isolators
6 ページ
-
Safety Barriers
27 ページ
-
Ex Magazine 2012
70 ページ
-
IS1+Remote I/O
16 ページ
-
Stahl - Catalog
1306 ページ
カタログアーカイブ
-
ISpac isolators
16 ページ
-
IS1 remote I/O
12 ページ
-
Fieldbus Solutions
16 ページ
-
Cable glands
18 ページ
-
Lighting
16 ページ
-
Company brochure
24 ページ
-
Marine Solutions
24 ページ