NIR-O™ PROCESS ANALYZER
1 / 8ページ

{{requestButtons}}

カタログの抜粋

NIR-O™ PROCESS ANALYZER - 1

PROCESS ANALYZER PRODUCT DATASHEET NIR-O™ PROCESS ANALYZER Full Spectrum Near-Infrared Spectrometer • Polyols: OH (hydroxyl) and acid number • Polymers: reaction endpoint, co-polymer ratio • Films: thickness, %T, %R High sensitivity • Measurement of moisture content Distillation Points, Olefins, % Oxygen • Solvent compositions

カタログの1ページ目を開く
NIR-O™ PROCESS ANALYZER - 2

NIR Process Analyzer Our NIR-O™ process analyzer offers remote multi-channel extended range near-infrared (NIR 10002100 nm) spectroscopic analysis. NIR-O provides excellent signal-to-noise ratio, wavelength stability, NIST traceable wavelength calibration, dual beam optics and built-in diagnostics. Process engineers, operators, and researchers will appreciate NIR-O’s ability to monitor up to12 process streams or points within a stream with accuracy, repeatability, and reliability. Additionally, the optional Stability Monitor System can provide confidence in hardware performance in the...

カタログの2ページ目を開く
NIR-O™ PROCESS ANALYZER - 3

Research-Grade Signal-to-Noise Ratio NIR-O’s dual beam design, coupled with its high output near-zero aberration scanning grating, puts more light into the fiber. This provides an excellent signal-to-noise ratio, which means better sensitivity in your measurements. Each NIR-O provides excellent wavelength accuracy (NIST traceable) and superb wavelength repeatability. Options: • ouch screen computer for local process visualization and control (only on general purpose and T Z-purge package) • -Purge package: Class 1 Zone 2 Groups IIB+ H2 ATEX, IECEx certification Z • -Purge package: Class 1...

カタログの3ページ目を開く
NIR-O™ PROCESS ANALYZER - 4

SMS Option Provides Peace of Mind An important consideration for successful process monitoring is the ability to continually validate the performance of the analyzer system's hardware components. The optional Stability Monitoring System (SMS) is a built-in package for NIR-O, which includes hardware and software to perform analyzer validation accoring to ASTM methodology. If the SMS option is selected, then one NIR-O channel must be dedicated to its use. Analyzer Performance Tests Typical SMS Level 0 Validation Process This topic is addressed in ASTM practice D-6122191 under instrument...

カタログの4ページ目を開く
NIR-O™ PROCESS ANALYZER - 5

SMS Validation Detects Changes in Performance The performance tests identified in the ASTM practice are diagnostics that can be used to detect changes in analyzer performance. This validation provides assurance that the measurement produced by the analyzer is a result of equipment that is operating properly. Since this is a hands-off procedure, it can be conducted in the background with no human intervention. The validation is done with an internal filter having a characteristic spectral signature. There are no liquids or other external sampling modes that are necessary. Everything is...

カタログの5ページ目を開く
NIR-O™ PROCESS ANALYZER - 6

OmniView Process Analysis Software OmniView is a standalone software package controlling all aspects of a NIR-O anlyzer. It provides full control of analyzer operations; diagnostics, data manipulation, event logging, trend graphs and alarms, calibration model security, and control of inputs and outputs. Communications via MODBUS TCP are included as standard. 4-20 mA analog signals are also supported with optional hardware. OmniView can be customized with "add-on scripts" to meet the needs of any process installation. A Comprehensive Package Support for third-party model chemometric tools...

カタログの6ページ目を開く
NIR-O™ PROCESS ANALYZER - 7

Remote Clients Minimum Computer Requirements • Intel® Dual Core processor • 4 GB RAM minimum, or as required for OS • Recommended 19 inch (minimum) monitor with 1080x1024 screen resolution • 100 MB Ethernet for network access • Microsoft Windows® OS – Win 7/10 Specifications Design: DG NIR Analyzer spectrometer, post-dispersed scanning grating Two (2) year limited warranty Dual Beam: 1 reference channel for each 6 available sample channels Light Source / Life Tungsten Halogen: 7.5 V, 15 W (5K hour recommended replace 10K hour life MTBF), additional spare lamp included Fiber Optic Cables:...

カタログの7ページ目を開く
NIR-O™ PROCESS ANALYZER - 8

PROCESS ANALYZER GAIN REAL-TIME INSIGHT INTO YOUR PROCESS Process Insights manufactures and delivers premium sensors, monitors, detectors, analyzers, instrumentation, and software that are mission-critical to keep your operations, personnel, and the environment safe – every day across the globe. Get the most reliable, precision analytical technologies available on the market today. We will work to match your needs and budget, and provide the optimal, and most stable process analysis solution for your application. CENTERS OF EXCELLENCE | PROVIDING PROVEN SOLUTIONS Process Insights is...

カタログの8ページ目を開く

Process Insightsのすべてのカタログと技術パンフレット

  1. HALO Max QCL™

    4 ページ

  2. SERIES 2000

    5 ページ

  3. QuickTONultra

    4 ページ

  4. T12

    4 ページ

  5. SERIES 3520™

    4 ページ

  6. SERIES 3000™

    4 ページ

  7. SERIES 2520™

    4 ページ

  8. ZRO 2000™

    4 ページ

  9. OXY-SEN™

    4 ページ

  10. SERIES 1300™

    4 ページ

  11. PCM 5000™

    2 ページ

  12. PCM 1000™

    4 ページ

  13. EVM™

    4 ページ

  14. Diamond 20™

    4 ページ

  15. Diamond MX™

    4 ページ

  16. RefinIR™

    4 ページ

  17. RovIR™

    4 ページ

  18. Fiber Optic Cable

    4 ページ

  19. G-SST™

    4 ページ

  20. RTD-SST

    4 ページ

  21. O-SST

    4 ページ

  22. SST

    4 ページ

  23. ClearView

    4 ページ

  24. LAB 508 UV-VIS

    8 ページ

  25. 508 UV-VIS

    8 ページ

  26. LAB NIR-O

    8 ページ

  27. QuickTOCtrace™

    8 ページ

  28. QuickTOCuv™

    4 ページ

  29. QuickCODlab™

    8 ページ

  30. ToxAlarm™

    4 ページ

  31. NitriTox™

    4 ページ

  32. QuickTOCeco™

    4 ページ

  33. QuickTOCairport™

    6 ページ

  34. RGA

    6 ページ

  35. MB

    8 ページ

  36. HRQ

    6 ページ

  37. APIMS

    2 ページ

  38. MAX-QMS

    2 ページ

  39. MAX300-EGA

    8 ページ

  40. MAX300-CAT

    4 ページ

  41. MAX300-BIO

    8 ページ

  42. MAX300-AIR

    8 ページ

  43. MAX300-RTG™ 2.0

    8 ページ

  44. MODEL ESS-SCVP™

    8 ページ

  45. HDT

    8 ページ

  46. XDT

    8 ページ

  47. XPDM

    8 ページ

  48. LPDT2

    4 ページ

  49. Spark H2 O in CO2

    6 ページ

  50. HALO KA H2O

    3 ページ

  51. HALO OK

    8 ページ

  52. HALO H2O in N2O

    2 ページ

  53. HALO H2

    4 ページ

  54. HALO 3 NH3

    3 ページ

  55. HALO 3 HCI

    3 ページ

  56. HALO 3 CH4

    3 ページ

  57. HALO 3 H2O

    4 ページ

  58. HALO 3 D2O/HDO

    4 ページ

  59. HALO 3 CO2

    4 ページ

  60. HALO 3 CO

    2 ページ

  61. HALO 3 CH2O

    2 ページ

  62. HALO KA Max

    4 ページ

  63. VeraSpec™ APIMS

    2 ページ

  64. 973

    8 ページ

  65. 573

    8 ページ

  66. Zircomat

    8 ページ

  67. 9610

    8 ページ

  68. 9800 Calorimeter

    4 ページ

  69. MAX300-RTG 2.0

    8 ページ

カタログアーカイブ